18
U
SING THE DEVICE
1) Description of the control panel
Temperature setting knob with Hors Gel
position and ability to restrict the range.
Time adjustment knob TURBO
1/4h, 1/2h, 1h, 2h.
Power On indicator
TURBO indicator
TURBO control
Heating ON/OFF switch
Heating indicator
1
3
4
6
5
7
2
2) Setting the CONFORT temperature
It is the temperature desired when the room is occupied.
a) Set the switch to
to the ON position, the
indicator lights.
b)Align the toothed screw
with the marking
: the indicator light
illuminates if the tempe-
rature is less than desired.
Wait a few hours for the temperature to stabilise.
If the temperature setting does not suit you, adjust it using the adjusting screw
. Proceed step-
by-step using the notches (
one notch at a time
).
The thermostat’s cycle takes several minutes. It is possible that the heating indicator may not react
instantaneously, but instead only on the next thermostat cycle.
3) Standby (
Hors Gel
) Mode
It is the mode enabling to maintain a temperature of approximately 7°C in the room in case of pro-
longed absence from the house.
a) Leave switch
on the Marche position.
b)Set the knob
to
.
4) Turbo mode
It is the mode enabling to set the device into Forced Operation, ensuring prompt temperature
increase in the room over the time defined (
maximum power for conventional models and fan acti-
vation point for models with ventilating fan
).
a) Leave the switch
on the Marche position.
b) Select the time for the Turbo using the knob
.
c) Press the command
, the indicators
and
light.
d)TheTURBO mode can be interrupted manually before the end of the time set. In order to do this,
press the command
again.
NB:
For piloted devices, only the heating stop and frost setting instructions are prioritised when
TURBO mode is activated (
the other instructions are inoperative
).