20
Installation
Where to install your device?
-
This equipment was designed to be installed in a residence. Please ask
your distributor before using it for any other purpose.
-
The device should be installed according to normal trade practice and
incompliance with legislation in the relevant country (NFC 15-100 for
France).
-
The equipment is class 2 and is protected against splashed water IP 24.
The device can be installed in volume 2 of a bathroom It’s forbidden
to install the device in the volume 1. The device is to be installed so
that switches and other controls cannot be touched by a person in
the bath or shower.
Do not install the device :
-
In a draught that might affect adjustment (for example, under a central
mechanical ventilation unit etc...).
-
Under a fixed power socket or near curtains or other combustible
materials.
Volume 1 No electrical device
Volume 2
Electrical device IPX4 .
(Standard EN 60335-2-
43 : 2003/A2: 2008)
> 250 mm
> 250 mm
> 200 mm
> 150 mm
Locate the device within minimum
distances from obstacles.
Do not install shelf above the device.
The bottom case must be at least 5
mm from the wall.
In order to avoid a hazard for very
young children, this device should be
installed so that the lowest heated rail
is at least 600 mm above the floor.
INSTALLING THE DEVICE