background image

Do not dispose this unit in a fire. IT MAY EXPLODE.
Keep unit away from children. The unit or parts of the unit might be a 
choking hazard.

Dispose of the unit legally and recycle when possible.

20  Specifications

1. Transmission frequency: 433 Mhz.
2. Maximum transmit power: 8 mW.

3. Transmission range up to 200 feet in open area. (range maybe shorter based 
    on interference present).

4. Indoor Temperature range: -4 °F ~ 158°F (-20 °C ~ 70 °C). 

5. Outdoor Temperature range: -58°F ~ 158°F (-50 °C ~ 70 °C).

6. Humidity range: 10% ~ 99%.

7. Temperature tolerance: +/- 2.0 °F (+/- 1.1 °C).

8. Humidity tolerance: ±2% from 30% to 80%; ±3% below 30% and above 80%.

9. Power: 2 X AAA 1.5V for base unit and 18650 lithium battery 3.7V for remote 
    sensor.

22  Disposal

You can help protect the environment! Please remember 
to respect the local regulations. Hand in the non-
working electrical equipment to an appropriate waste 
disposal center.

23  FCC STATEMENT OF COMPLIANCE

This device complies with Part 15 of the FCC rules. Operation is subject to the 
following two conditions:

l) This device may not cause harmful interference.

2) This device must accept any interference received, including interference 
     that may cause undesired operation.

Warning:

 Changes or modifications to this unit not expressly approved by the 

party responsible for compliance could void the user's authority to operate the 
equipment.

NOTE:

 This equipment has been tested and found to comply with the limits for 

a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are 
designed to provide reasonable protection against harmful interference in a 
residential installation. This equipment generates, uses and can radiate radio 
frequency energy and, if not installed and used in accordance with the 
instructions, may cause harmful interference to radio communications. 
However, there is no guarantee that interference will not occur in a particular 

Do not remove any screws.

-10-

-11-

EN

EN

19  Warnings

Do not subject the unit to excessive force, shock, dust, temperature or 
humidity.

Do not immerse the unit in water.

21  Disposal of batteries

Please dispose of your batteries properly in containers especially 
set up as retailers. Batteries do not belong in the household 
waste. Dispose of batteries at an approved facility or at your 
recycling center. Contact your local council if in doubt.

If the base station is attached to a refrigerator or a metal object by magnet, 
thetransmission may be shorter. Remove the base station from the 
refrigerator or the metal object and place the base station and remote 
sensor as close as possible.

Signals from other electronic devices may cause interference. Place the 
base station and receiver away from these devices.

Summary of Contents for TP-67

Page 1: ...Model No TP 67 V201808 EN FR 31 Wireless Weather Station Instruction Manual English 2 Fran ais 14...

Page 2: ...0 3 below 30 and above 80 6 Low battery indication for both base station and remote sensor 7 Backlight LCD display 8 Tabletop and wall mountable design Base is detachable 9 Rain proof design for remot...

Page 3: ...socket located on the back of the remote sensor b Plug the wall charger into a standard AC outlet c The red light on the remote sensor will light up d Charge the remote sensor for at least 4 hours unt...

Page 4: ...mote channel you want displayed permanently 12 Thermometer 1 Once the remote sensor and the base station are synchronized the indoor temperature humidity and outdoor temperature will both be shown the...

Page 5: ...er forecasting is for reference and for domestic use only Do NOT rely on the weather station s weather forecast for any serious matters such as health business and financial decisions and or agricultu...

Page 6: ...by the party responsible for compliance could void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pu...

Page 7: ...Conformity Hereby the manufacturer declares that this product complies with the basic requirements and applicable regulations of the Radio Equipment Directive 2014 53 EU the EMC Directive 2014 30 EU T...

Page 8: ...lus pr cises 3 Fonctionnalit s et sp cifications du produit 1 cran LCD Affiche la temp rature ext rieure actuelle l humidit et la temp rature int rieures la pression atmosph rique y compris son histor...

Page 9: ...dit 1 indique que la temp rature et l humidit ont une tendance la hausse 2 indique que la temp rature et l humidit ont une tendance constante 3 indique que la temp rature et l humidit ont une tendance...

Page 10: ...rieure clignotera pendant 3 minutes ce qui indique que la station est en mode de synchroni sation et qu elle attend que les capteurs soient reconnus 3 Configurez le s lectionneur de canal l arri re d...

Page 11: ...e minimum enregistr es MIN est affich sur l cran c Pour effacer et r initialiser les records max min laissez appuy sur MAX MIN pendant 3 secondes 3 Tendance de temp rature et d humidit 3 types d ic ne...

Page 12: ...surface plane l int rieur ou l ext rieur Assurez vous que le capteur soit port e de la station de base avec le moins d obstructions possibles Bien que le capteur soit con u pour tre tanche il doit tou...

Page 13: ...u modifications qui ne sont pas express ment approuv s par la partie responsable de la conformit pourraient annuler l autorit des utilisateurs op rant sur l quipement REMARQUE Cet quipement a t test e...

Page 14: ...vice client par t l phone ou e mail pour savoir comment emballer et retourner le produit ThermoPro Cette garantie vous donne des droits sp cifiques l gaux et certains droits suppl mentaires selon l ta...

Reviews: