![Thermoplan Black&Whute3 CBT Troubleshooting Manual Download Page 54](http://html1.mh-extra.com/html/thermoplan/blackandwhute3-cbt/blackandwhute3-cbt_troubleshooting-manual_1105911054.webp)
REV-1
6.54
1
A
20
F
25
H
6
C
© 2011 by Thermoplan AG, Änderungen vorbehalten
SECTION 6
Technical manual
Connection settings lower connector:
1
Working Level Probe
8
not set
15
24VDC
22
Gate Triac Steam 1
2
Security Level Probe
9
Pressure Switch Signal
16
not set
23
A2 Triac Steam 1
3
GND
10
Pressure Switch 5VDC
17
not set
24
Gate Triac Steam 2
4
not set
11
not set
18
not set
25
A2 Triac Steam 2
5
not set
12
Mixing / tea valve
19
not set
6
not set
13
Steam valve
20
L
7
not set
14
Filling valve
21
N
Rapid test TS module
Connection settings upper connector:
A
L2
C
N
E
not set
G
not set
B
not set
D
GND
F
L3
H
N
8.5
Quick test Steam module
8
Steam module