SECTION 6
Technical manual
6.1
Error messages Hydraulic module
6
Hydraulic module
Error no. / picture
Text
Cause
Fix
TX0101
NTC coffeeboiler open
Problem with NTC in coffee boiler
Check NTC and if necessary
exchange
TX0115
Flow error
Too low water flow
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
TX0116
Overtime error
Product is not dispensed correctly
because of too low water flow
1. Dispense product again
2. Check flowmeter
3. Check pump
TX0125
Waterflow error
No water pressure or flowmeter
defective
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
TX0141
NTC coffee boiler short-circuit
NTC on coffee boiler had a short
circuit
Change NTC on coffee boiler
TX0151
No waterflow detected
No water pressure or flowmeter
defective
1. Open mains water connection
2. Empty grounds drawer
3. Perform rinse
4. Check flowmeter
5. Check pump
TX0154
Milk pump: no pulse
Milk pump not recognised
TX0155
Water pump: no pulse
Milk pump not recognised
TX0161
Please wait
Machine rinses
Wait until rinse is finished
TX0201
Cold start rinse
Please press rinse key
Rinse for start- and warm-up of
machine
Press rinse key