![Thermoplan Black&White3 CT Installation, Initial Start-Up, Safety Download Page 7](http://html1.mh-extra.com/html/thermoplan/blackandwhite3-ct/blackandwhite3-ct_installation-initial-start-up-safety_1105908007.webp)
2.7
REV-5
SECTION 2
© 2015 by Thermoplan AG, Subject to change
Technical Manual
Installation refrigerator UT (under counter)
Connection parts set
1
2
3
1
2
3
1x 123.966 Milk hose undercounter ø6/4x1700mm
1x 123.969 FEP pipe ø4/2x2700mm
1x 118.035 Connect. cable ext. CTM-UT-RF BW2/BW3
... the other end of the tube to the
connector at the bottom back of
the coffee machine.
Plug-in the connection cable (part
3) at the bottom back of the refri-
gerator and ...
This drawing shows how the tubes
and the cable are plugged correctly to
connect a BW3.
Connect the FEP pipe (part 2) at
the bottom back of the refrigerator
and ...
Connect the milk hose (part 1, see
set above) to the available elbow
connector on the left side of the
refrigerator and ...
... the other end of the pipe to the
connector at the bottom of the
coffee machine.
Adjust the milk rinse times in the service
menu according to the tube lengths used.
Recommended settings for milk hose length of 1700mm:
Rinsetime after milkproduct
2.5 sec
Rinsetime after milkbeverage hot 6.0 sec
Milksucktime after milkrinse
9.0 sec
Coldmilksucktime
6.0 sec
... the other end of the cable at
the bottom back of the coffee
machine.
1
4
7
2
5
3
6
1
1
1
2
2
2
3
3
3
BW3-RF-UT
BW3-CTM
BW3-CTMC