2
1
2
4
3
5
9
10
Item Quantity
Description
1
1
RTV Tube
2
1
Power Connection Boot
3
2
Conductor Wire Pins
4
1
Braid Wire Pin
5
1
Ground Sleeve
6
1
End Cap
7
1
Tape Strip (PETK-3-ZT only)
8
1
Grommet (PETK-3-ZT only)
9
1
End Termination Caution Label
1
2
6
4
3
8
5
7
9
8
12
Item Quantity
Description
1
1
Expediter Assembly
Support Cap with O-Ring
Threaded Grommet Compressor
Grommet
Support Base with O-Ring
2
1
Junction Box Lid
3
1
Junction Box Base with O-Ring & M25 Dust Cap
4
1
Nut
5
1
Banding
6
1
Thermostat w/ Terminal Blocks
(Refer to terminal speci
fi
cations for maximum allowable wire size)
Thermostat Type Control Range
ZT-C-100 0
°
C to +100
°
C
ZT-C-200 0
°
C to +200
°
C
ZT-C-300 0
°
C to +300
°
C
ZT-C-500 20
°
C to +500
°
C
7
1
Capillary Armouring w/ Glands
8
1
Junction Box Cord
9
1
Blind Plug
10
1
Bracket
11
3
Screws
12
3
Washers
Ter
minato
r Z
T
IP66
-45
°
C
Ta
+
55
°
C
For
use
as an adjustable co
ntro
l th
erm
os
ta
t
wi
th
The
rmon heating
ca
ble
s
ys
te
m
s
II 2 G & D E
Ex ed I
I C T5
0539
DEMKO 02A
TEX132552X
Order Separately . . .
IEK Insulation Entry Kit (per cable)
IEK-SXL: for RSX, VSX,
IEK-SXM for BSX
IEK-SXS
for KSX, HTSX
IEK-HPT
for HPT, FP
11
7
190mm
50mm
155mm
200mm
1
7
2
5
II 2
G
D E
x db e
b IIC T5-T6, Ex tb IIIC T
100
°C-
T8
5°
C,
F
M
1
0A
TE
X
0
0
5
8
X
IEC
Ex F
MG 1
0.0022X
Ex db
eb I
IC T
5-T
6,
Ex
tb
II
IC
T
1
0
0
°C
-T
8
5
°C
PN 27656
Te
rm
inator Z
T
Fo
r u
se
as
an
adj
ustable
control/lim
iter t
her
m
os
tat
IP
6
6
-6
0°
C
≤
Ta
≤
+50
°C T5, 100°C; -60°C
≤
Ta
≤
+4
0°
C
T6
, 8
5
°C
6
205mm
Terminator
TM
ZT-P-WP
INSTALLATION PROCEDURES
Kit Contents . . .
The following installation procedures are suggested
guidelines for the installation of the Terminator ZT-P-WP Kit.
Receiving, Storing and Handling . . .
1. Inspect materials for damage incurred during shipping.
2. Report damages to the carrier for settlement.
3. Identify parts against the packing list to ensure the
proper type and quantity has been received.
4. Store in a dry location.
Dimensions . . .
Order Separately . . .
PETK Power and End Termination Kits (per cable)
PETK-1
for RSX, VSX, BSX
PETK-2
for KSX, HTSX
PETK-3-ECM
for HPT, FP
Warnings . . .
• Due to the risk of electrical shock, arcing and
fi
re caused
by product damage or improper usage, installation or
maintenance, a ground-fault protection device is required.
• Installation must comply with Thermon requirements
(including form PN 50207U for Ex systems) and be installed
in accordance with the regulations as per the norm EN IEC
60079-14 for hazardous areas (where applicable), or any
other applicable national and local codes.
• Component approvals and performance ratings are based
on the use of Thermon speci
fi
ed parts only.
• De-energize all power sources before opening enclosure.
• Avoid electrostatic charge. Clean only with a damp cloth.
• Keep ends of heating cable and kit components dry before
and during installation.
• Minimum bending radius of heating cable is 32 mm (except
HPT is 57 mm and FP is 19 mm).
• Individuals installing these products are responsible for
complying with all applicable safety and health guidelines.
Proper Personal Protective Equipment (PPE) should be
utilized during installation. Contact Thermon if you have any
additional questions.
• Consult the manufacturer for dimensional information on the
fl
ameproof joints for repair.
Certifi cations/Approvals . . .
1725 II 2 GD Ex db eb IIC T5-T6, Ex tb IIIC T100°C-T85°C FM10ATEX0058X
IP66; -60°C
≤
Ta
≤
+55°C T6, 85°C 16 Amps Max
-60°C
≤
Ta
≤
+50°C T5, 100°C 25 Amps Max
Ordinary & Hazardous Locations
FMG 10.0022X Ex db eb IIC T5-T6, Ex tb IIIC T100°C-T85°C
Tools Required . . .
Terminator-LN-Tool
(order separately)
3 mm
8 mm
28 mm