background image

Part No. 12430.Rev.1   June 2021   Printed in Canada

XB Series

CE Explosion-Proof Convection Panel Heater

Installation, Operation, & Maintenance Instructions

Special Notes

The following special notices highlight important 
information in the installation and maintenance sections. 
Each serves a special purpose and is displayed in the format 
shown:

This symbol indicates a potentially hazardous situation, 
which, if not avoided, can result in personal injury or 
damage to the equipment.

This symbol indicates a potentially hazardous 
situation, which, if not avoided, may be a shock 
hazard.
This symbol indicates an imminently hazardous 

situation, which, if not avoided, could result in death or 
serious injury.

CAUTION

CAUTION

WARNING

ISO 9001

Depening on the particular model ordered, the heater is suitable for the following 

areas:
II 2G EX db IIC T3 or T4, Gb

-60°C ≤ Tamb ≤ 40°C

Summary of Contents for Norseman XB Series

Page 1: ...ormat shown This symbol indicates a potentially hazardous situation which if not avoided can result in personal injury or damage to the equipment This symbol indicates a potentially hazardous situatio...

Page 2: ...A Pre installation 3 B Installation 3 B 1 General Requiprements 3 B 2 Wall Mounting 4 B 3 Floor Mounting 4 B 4 Thermostat Installation 5 C Wiring 5 D Replacement Thermostats 6 E Start up 6 F Maintenan...

Page 3: ...ch depending on the model could weigh up to 45 kg 100 lbs Otherwise use the brackets supplied to stand the heater on the floor 2 Do not recess the Norseman XB CE heater into the wall Use of the bracke...

Page 4: ...d lock washers Figure 4 Figure 4 Attach heater to mounting brackets B 3 Floor Mounting Step 1 Position heater face down on the floor with terminal box towards the wall Figure 5 page 4 Figure 5 Floor m...

Page 5: ...d in kit number XTKW04483CE Follow the instructions supplied with the kit C WIRING 1 Whenever hazardous materials are present ensure that the terminal housing covers are secure before powering the hea...

Page 6: ...E The thermostat temperature range is 18 to 40 C 0 to 100 F with an operating differential of 3 to 4 C 5 to 7 F 2 Install the terminal box cover and tighten securely 3 Check to ensure that all plugs s...

Page 7: ...administration F MAINTENANCE 1 Periodically inspect the heater installation to ensure that all connections fittings plugs screws covers etc are tight and free of corrosion 2 Check the extrusions of th...

Page 8: ...applies to paint finishes except for manufacturing defects apparent within 30 days from the date of installation The Company neither assumes nor authorizes any person to assume for it any other oblig...

Reviews: