INTRODUCTION 

 

Thank you for selecting this product from the large range of products manufactured in 
Australia by Thermoline Scientific. 
 
The materials incorporated in this design have been carefully selected for their 
durability, technical performance, and practicability, the resultant product is one we 
are proud of.

 

 
 

THE MANUAL 

 
Please familiarise yourself with the information contained in this manual before using 
the equipment. 
 
Ensure that the manual is kept safe but accessible for current and future operators to 
refer to.

 

 
 

UNPACKING 
 

Remove the equipment from the packing material, check that it is complete. 
Assemble the components and inspect for damage. 
 
Retain the packaging materials until the equipment has been thoroughly tested. 
 
Notify the detail of any damage without delay to your supplier, or Thermoline 
Scientific.

 

 
 

LOCATION 
 

Place the equipment in on a firm level surface. Confirm that the power supply is 
suitable for this equipment, refer to the rating plate for details. To control temperature 
effectively, the equipment should be located in a stable ambient. 
When in position unscrew the two (2) adjustable feet (located at the front of the 
cabinet) until they just lift the castors from the floor. 
 
 

 

 

 

 

 

WARNING: 

Ensure that the electrical 

 

 

 

 

 

 

outlet is earthed and is of the correct 

 

 

 

 

 

 

voltage and is capable of carrying the 

 

 

 

 

 

 

stated current load.

 

 
 

INTENDED USE 
 

This equipment is used to provide a mild temperature controlled environment for use 
in microbiology, immunology, culture departments, stability, storage of veterinary 
samples, education and many more.

 

 
 
 
 
 
 

Summary of Contents for TI-1000F

Page 1: ...ty Ltd T A Thermoline Scientific ABN 80 000 859 129 10 12 Ross Place Wetherill Park N S W 2164 Australia P O Box 6862 Wetherill Park Delivery Centre N S W 1851 Australia Phone 02 9604 3911 Internation...

Page 2: ...e is a Possibility of damage to the Equipment To maintain safe operation of this equipment be aware of the ALERT BOXES located throughout these operating instructions CONTENTS SAFETY INFORMATION 2 ALE...

Page 3: ...he packaging materials until the equipment has been thoroughly tested Notify the detail of any damage without delay to your supplier or Thermoline Scientific LOCATION Place the equipment in on a firm...

Page 4: ...ing conditions The door s close on a magnetic gasket and are further secured with positive action door latch es The external is powder coated steel The desired operating temperature is set at the temp...

Page 5: ...eel is under most conditions extremely resistant to corrosion This is in part due to the addition of chromium and nickel to the steel and the formation of a durable chromium oxide at the surface durin...

Page 6: ...ues to trip it may indicate an electrical fault exists Switch Off the power and consult a qualified technician TEMPERATURE CONTROLLER SENSOR This is a Eurotherm 3216 PID control with digital temperatu...

Page 7: ...ment as fire or explosion may result This cabinet contains components that may ignite such materials WARNING 2 Do not introduce water into this equipment as the excessive vapour may result in prematur...

Page 8: ...ntroller shifting the input value of the sensor This correction value is first entered when the equipment is under test at the factory Further small adjustments can be made by the operator to compensa...

Page 9: ...t value with few exceptions is between 0 5 and 1 5 The need to use a value outside this range should be carefully considered If in doubt return the value to zero and recalculate the offset value The s...

Page 10: ...able to accept the 4 20mA signals representing 0 0 to 100 0 C and 0 to 100 RH Maximum load to be applied to the analogue output is 500 ohms Pin connections for retransmission socket ALARMS No volt al...

Page 11: ...imply contact Thermoline Scientific If warranty service is required Thermoline Scientific will endeavour to have an authorised service organisation carry out the work if there is an available agent ho...

Page 12: ...y by Any defect in material or workmanship of or any other defect whatsoever in or unsuitability for any purpose of the goods or any part of the goods or default or negligence on the part of Thermolin...

Reviews: