Thermokon TS1 3Ph 02 Technical Data Manual Download Page 2

2

 

1.

This manual contains instructions, which have to be observed for your personal safety and for the pre-
vention of material damage. The instructions about your personal safety are highlighted with a warning 
triangle labelled with three exclamation marks, hints about material damages are listed with a warning 
triangle and one exclamation mark.

Danger-symbol

Personal injury 

may

 occur, if appropriate safety precautions are 

not taken.

Caution-symbol

Material damages may occur, if appropriate safety precautions are 
not taken into account.

Disposal regulations

The devices contain electrical components and must not be disposed together with house-
hold garbage. The devices for disposal have to be recycled according to local and currently 
valid regulations for electronic waste.

Qualified personnel

The corresponding device/system may only be set up and operated in conjuntion with this documenta-
tion. Commissioning and operation of the device/system may only be performed by 

qualified person-

nel

. Qualified personnel within the meaning of the safety instructions in this documentation are per-

sons with the authority to put electric circuits into operation, provide ground connections and label them 
according to current safety regulations.

The device should only be used in applications described in this document. The reliable and proper use 
of the product depends on appropriate transport, storage, installation and careful commissioning.

2.

Use of the document

This instruction should demonstrate the technical application possibilities of the thyristor controller to 
the engineer in charge.

Target group

The document should assist the user during commissioning. It also helps in case of service and main-
tenance work. It supports the planner and project engineer with the conception of new plants.

Necessary competence

Generic skills in the field of electrical engineering are necessary.

Validity

The present document is valid for the thyristor controller of the type 

. It contains the 

currently valid description of the unit. We reserve the right to attach new descriptions of the devices. 
This involves types and options with modified version status of the technical documents.

Standards and approvals

The  thyristor  controller  of  the  type 

  are  based  on  the  IEC/EN  60947-4-3 

standard.

Important safety instructions

General instructions

TS1 3Ph, TS SP 3Ph

TS1  3Ph,    TS1  SP  3Ph

Disclaimer

It lies within the responsibility of the plant manufacturer of the technical equipment or machine to ensu-
re the proper overall function. The producer can not guarantee all properties of the overall system or 
the machine.

!!!

!

Thermokon Sensortechnik GmbH - Thyristor controller TS1 3Ph, TS1 SP 3Ph

Summary of Contents for TS1 3Ph 02

Page 1: ...1 Explanation phase angle control Ph 4 3 2 Explanation multicycle control SP burst firing control 5 4 5 6 7 Meaning of the clamp connections and LEDs 9 8 9 Survey of the individual types 11 10 Technic...

Page 2: ...tions The device should only be used in applications described in this document The reliable and proper use of the product depends on appropriate transport storage installation and careful commissioni...

Page 3: ...vices are powered internal by the mains voltage Optional can devices with different mains voltage be supplied with an external auxiliary voltage power unit with heat sink and thyristor wiring control...

Page 4: ...chronous motors fan motors or pump motors a phase angle control can be used to control speed and torque Due to the controllability of the positive and negative half wave it is possible to adjust exact...

Page 5: ...T of one second 1s corresponds to 50 full waves Possible application ares are electric heatings heat technology and drying technology Newer models offer combinations of phase angle control and multic...

Page 6: ...functional unit of the entire plant The control electronics of the thyristor controllers are implemented according to valid EMC standards The builder of the plant has to supply the plant with appropri...

Page 7: ...ing measures help to reduce the radiated interference energy Electrical lines between thyristor controller and load can be laid shielded Thereby the shield must not replace the PE line Four wire cable...

Page 8: ...urces Recommended connection The mains connections the connection to the load and the control connections have to be laid in sepa rate cables In order to avoid faults the electronic control connection...

Page 9: ...itch Monitoring LED s Y1Y2 3 4 5 9 8 Thyristor controller TS1 3Ph TS1 SP 3Ph Mains 100 Ua 0 20mA 0 10V ON 100 Ua 0 10V or 0 20mA 0V Activation 2 5kW 10kW alternative controlling Load voltage Ua Mains...

Page 10: ...T1 T2 T3 Y1Y2 3 4 5 9 8 load ohm or inductive Option if external supply voltage is used Thyristor controller TS1 3Ph TS1 SP 3Ph Mains 100 Ua Switch 0 20mA 0 10V ON alternative control Output terminals...

Page 11: ...ins fuse Frame size TS1 3Ph TS1 SP 3Ph H W D 100 mm 100 mm 100 mm 75 mm 75 mm 75 mm 2 mm 33 mm 25 mm Fan Mains Mains Mains 100 Ua 100 Ua 100 Ua PE PE PE Y1 Y1 Y1 Y2 Y2 Y2 3 3 3 4 4 4 5 5 5 9 9 9 8 8 8...

Page 12: ...tion 0 45 C storage 10 70 C LED mains green device is ready for use LED 100 Ua green device has reached full conduction Relais 100 Ua Contact rating 250V AC 3A 24V DC 3A Max load current Phase sequenc...

Reviews: