GHP

Summary of Contents for FA60 Series

Page 1: ...ury and properTy loSS or daMage FroM The hazardS oF Fire exploSion Burn aSphyxiaTion CarBon Monoxide poiSoning and or eleCTriCal ShoCk only perSonS who Can underSTand and Follow The inSTruCTionS Shoul...

Page 2: ......

Page 3: ...ing MaTerialS paper or CardBoard a SaFe diSTanCe away FroM The heaTer aS reCoMMended By The inSTruCTionS never uSe The heaTer in SpaCeS whiCh do or May ConTain volaTile or airBorne CoMBuSTiBleS or pro...

Page 4: ...esult in poisoning or death 3 Other standards govern the use of fuel gases and heat producing products in speciic applications your local authority can advise you about these IMPORTANT read ThiS uSer...

Page 5: ...A NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 The minimum and maximum inlet pressures to the regulator from the gas tank are 5 psi and bottle pressure respectively use only th...

Page 6: ...125 Series Only Parts Required 4 Screws ST3 5x10 and 2 Cord wrap attachments place the cord wrap attachment as shown then use phillips screwdriver to tighten the screws and secure the cord wrap attach...

Page 7: ...ssed gas Cylinder valve outlets and inlet Connections A safety relief valve having direct communications with the vapor space of the tank An arrangement of vapor withdrawal The propane LP gas pressure...

Page 8: ...knob fully clockwise Ensure that the cylinder is fully upright for vapor withdrawl see size capacity page 6 2 Connect hose to heater inlet Tighten irmly using a wrench You must use the regulator suppl...

Page 9: ...at all times The hose assembly should be visually inspected prior to each use of the heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to t...

Page 10: ...hose before performing any Mainte nance functions Unplug the unit from the 120V receptacle 2 Keep unit clean and keep the inside of the torpedo housing debris free 3 Have unit checked by a qualiied te...

Page 11: ...ower to heater 1 Check current to electric outlet If voltage is correct electrical connec7on is made check power cord and extension cord for 2 Fan blade contacts inside of heater housing 2 Be sure tha...

Page 12: ...aMs 100K 125K 150K Models only 100K 125K 150KS lo modelos 100K 125K 150K Les mod les Seulement PROPANE CONSTRUCTION HEATER LPFA125 Series Models Only LPFA 125 Series S lo Modelos LPFA125 S ries Les mo...

Page 13: ...12 PROPANE CONSTRUCTION HEATER rePlaceMent Parts list MODELS RMC FA60 Series LPFA125 Series...

Page 14: ...6 15 GUARD FAN BLACK 1 2304828 2304939 16 MOTOR BRKT 1 2304937 2304938 17 VALVE GAS 1 5051233 5051235 18 PRESSURE SWITCH 1 N A 2305976 19 VALVE BRKT 1 2304624 2304624 20 BASE ASSY BLACK 1 2304923 2304...

Page 15: ...long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or excl...

Page 16: ...register your warranty on the internet at www ghpgroupinc com Complete the entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here GHP Group Inc...