Figure 3

Power Cord

L1

L2

EARTH

The distance between two brackets and power supply (see 

Figure 1

) are different with dif-

ferent models, please read the following list first before installation.

Model

L2

L1

Power supply

HS1500NA

24”(60 cm)

10”(25 cm)

110-120V~, 60Hz, with power plug

HS1800NA

27”(70 cm)

10”(25 cm)

110-120V~, 60Hz, with power plug

HS2400NA

40”(100 cm)

10”(25 cm)

220-240V~, 60Hz, without power plug

HS3000NA

48”(120 cm)

12”(30 cm)

220-240V~, 60Hz, without power plug

Figure 1

Attach part (A) of the bracket to a wall or ceiling in such a way that it can support the appli-
ance’s weight.

Figure 2

Attach part (B) of the bracket to the device using the screws and angle brackets supplied in 
the parts (C)(D).

Figure 3

Determine the desired angle for the device. Attach the two parts (A)(B) of the bracket to 
each other using the screws supplied in the pack (C). Then connect power cord with power 
supply.

Never route the power supply cable along the heating surface.

5 USER INSTRUCTIONS

The device’s heating surface gets extremely hot. Never touch the appliance when 

it is switched on.
After use, always allow the device to cool down for at least 30 minutes before 

touching it.
Do not turn on the device when objects are present underneath it within a dis-

tance of 40”(100 cm).

Remove all the packing materials before turning on the heater.

manual thermoflow far infrared heater -en & fr.indd   6

2019/11/12   17:14

Summary of Contents for HS1500NA

Page 1: ...nt Heater Radiateur infrarouge lointain lectrique User manual Manuel de l utilisateur Troubleshooting Warranty Information Information sur le d pannage et la garantie P N 2329088 V 02 2019 11 manual t...

Page 2: ...SHOOTING 8 TECHNICAL SPECIFICATIONS 9 WARRANTY CONDITIONS 9 0 TABLE DES MATI RES TABLE DES MATI RES 2 INTRODUCTION 10 MESURES DE S CURIT 10 EMBALLAGE 11 INSTRUCTIONS DE MONTAGE 11 INSTRUCTION SUR SON...

Page 3: ...val of lime and water scale deposits may only be car ried out by a licensed contractor The applicable regulations and local laws must always be observed Symbols The following symbols are used in these...

Page 4: ...Internal modifications to the product may cause problems if this work is not carried out by authorized and qualified technical persons The warranty only applies if the product has not been modified i...

Page 5: ...away from the ceiling Do not place combustible materials in the vicinity of the device Installation The device should be installed in accordance with the drawings below Any other installa tion positio...

Page 6: ...ach part B of the bracket to the device using the screws and angle brackets supplied in the parts C D Figure 3 Determine the desired angle for the device Attach the two parts A B of the bracket to eac...

Page 7: ...ndicator F Blue 2 hours automatic shutdown timer LED indicator G Blue 4 hours automatic shutdown timer LED indicator The infrared remote control has two buttons and a light as shown in the figure belo...

Page 8: ...to switch off the power or pull out the plug Always switch off the device after use Note The red LED indicator light turns off when the device is turned off This does not mean that the appliance has c...

Page 9: ...sage or operating conditions or defective maintenance or repair work Duration The warranty shall be valid for 24 months The warranty period shall commence on the day on which the product is purchased...

Page 10: ...de calcaire et d eau ne peuvent tre effectu s que par un entrepreneur agr La r glementation en vigueur et les lois locales doivent toujours tre respect es Symboles Les symboles suivants sont utilis s...

Page 11: ...oncteur dans votre panneau lectrique Des modifications internes au produit peuvent cau ser des probl mes si ce travail n est pas effectu par des personnes autoris es et qualifi es La garantie ne s app...

Page 12: ...ins 10 cm 4 du plafond Ne placez pas de mat riaux combustibles proximit de l appareil Installation L appareil doit tre install conform ment aux sch mas ci dessous Toute autre position d installation p...

Page 13: ...appareil en utilisant les vis C et les querres D fournies Figure 3 D terminer l angle d sir pour l appareil Fixez les deux parties du support A B l une l autre l aide des vis C fournies dans l emball...

Page 14: ...E Bleu Arr t automatique apr s 1 heure Indicateur DEL F Bleu Arr t automatique apr s 2 heures Indicateur DEL G Bleu Arr t automatique apr s 4 heures Indicateur DEL La t l commande infrarouge a deux b...

Page 15: ...lectionn e 1 2 ou 4 heures Si vous souhaitez teindre l appareil avant la fin de la dur e d finie vous devez appuyer sur le bouton B Un interrupteur 250V 16A doit tre install la prise de courant Lorsq...

Page 16: ...100x205x1310mm 100x205x1600mm 100x205x1915mm Poids net 11 0 lb 5 0 kg 13 23 lb 6 0 kg 15 4 lb 7 0 kg 19 8 lb 9 0kg Poids net 13 3 lb 6 0 kg 15 43 lb 7 0 kg 17 6 lb 8 0 kg 22 0 lb 10 0kg 9 CONDITIONS D...

Page 17: ...vement de produits d fectueux ou l installation de produits r par s ou nouveaux Invalidit de la garantie Toute tentative de r paration effectu e par un client ou une tierce partie non autoris e par Th...

Page 18: ...18 manual thermoflow far infrared heater en fr indd 18 2019 11 12 17 14...

Page 19: ...19 manual thermoflow far infrared heater en fr indd 19 2019 11 12 17 14...

Page 20: ...SUMEC Machinery Electric Co Ltd manual thermoflow far infrared heater en fr indd 20 2019 11 12 17 14...

Reviews: