DIMENSIONS AND MAXIMUM TEMPERATURE

 

Ext.  Ext.  Ext.  Int.  Int.  Int. Max.  Max. 

 

Width 

Depth 

Height 

Width 

Depth  Height  Oper.  Oper. Temp 

 

inches  inches inches inches inches inches Temp  Dry 

Well 

 

       

°F 

°F

742 HW-CT

  31.750  33.00 13.125  – 

– 

– 

– 

211

744 HW-CT

 60.125  33.00 13.125 – 

–  –  – 

211

WEIGHT

 

Net Shipping 

 

Weight Weight 

Model 

lbs lbs

742 HW-CT

 110  200

744 HW-CT

 215  310

SPECIFICATIONS

INTRODUCTION

GENERAL

Thermodyne cabinets are produced with quality 
workmanship and materials. Proper installation, 
operation and maintenance will result in many 
years of satisfactory performance. It is suggested 
that you thoroughly read this manual in its entirety 

and carefully follow all of the instructions provided. 
The cabinets described in this manual are 
programmable for the desired holding temperature. 
The factory setting is 185° F unless otherwise 
specified.

TOP VIEW

ELECTRICAL

REAR VIEW

FRONT VIEW

SIDE VIEW

DRAIN

60

1

8

13

1

8

EXTERIOR WIDTH

EXTERIOR

HEIGHT

33

EXTERIOR DEPTH

11

8

9

1

2

Figure 1: Outline Dimensional Drawing, 744HW-CT Tabletop

Summary of Contents for 742HW-CT

Page 1: ...additional information on Thermodyne Foodservice Products Inc or to locate an authorized parts and service provider in your area visit our website at www tdyne com Please visit our website to Registe...

Page 2: ...connecting the unit to the electrical supply verify that the electrical connection agrees with the specifications on the data plate Failure to comply with this procedure can cause property damage inju...

Page 3: ...property damage injury or death Do not use or store gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance Failure to comply can cause property damage injury or d...

Page 4: ...PECIFICATIONS 7 OPERATION 8 STARTUP 8 Temperature Controller Set Up Procedures 8 Keypad Operation 8 Set Up 9 To Toggle Between F and C Readout 9 Preheating 9 CLEANING AND MAINTENANCE 10 Electrical LOC...

Page 5: ...produced with quality workmanship and materials Proper installation operation and maintenance will result in many years of satisfactory performance It is suggested that you thoroughly read this manua...

Page 6: ...he product is damaged 1 Save all packing material 2 Contact Thermodyne Customer Service Representatives immediately 3 Receiver must call the carrier to schedule aninspectionofthedamagedmerchandise wit...

Page 7: ...ctrical cord and plug are located at the right rear of the unit The minimum clearance for proper air circulation on back should be 4 and 2 on at least one side Allow adequate access space for operatin...

Page 8: ...messagesindicatingcommunication and auto tuning errors 5 Re set the dwell timer function 6 Enter the manual control menu if the sensor has failed STARTUP The oven cabinet and hot wells are hot Use car...

Page 9: ...level in the Heater or Reservoir Tanks To Toggle Between F and C Readout 1 Press the Scroll key 2 3 times until the upper display reads unit 2 Press the Up or Down key to choose Preheating Preheat th...

Page 10: ...ly to ensure the long life of the equipment Routine cleaning will also lessen stainless steel abrasion STAINLESS STEEL CARE Cleaning Stainless steel contains 70 80 iron which will rust if not properly...

Page 11: ...emove heat tint follow the routine cleaning procedure Stubborn heat tint will require heavy duty cleaning Toreduceheattint limittheexposureofequipment to excessive heat DRAINING WATER FROM HOT WELLS 1...

Page 12: ...due to low water level cut out 2 Water level probe defective 3 System leak 1 Main heater tanks low on water Add water and determine cause of water loss 2 Repair or replace 3 Repair leak Heater s not...

Page 13: ...RD TERMINALS 120 208 240 VOLT SUPPLY 2100W HEATER 2100W HEATER 2100W HEATER SURFACE HEATERS WELL 80 TO 260 VOLTS IN TEMPCO B41 1 2 1 2 1 2 1 2 1 2 3 3 2 1 3 2 1 TE1 TE2 TE3 TE4 TE5 TE7 TE6 TC TC POWER...

Page 14: ...Inc is limited specifically to the aforementioned No additional guarantees or warranty expressed or implied to include without limitation warranties of Fitness or Merchantability with respect toThermo...

Page 15: ...15...

Page 16: ......