Do not cross the product onto itself.
-
Ensure good contact between the product
and the surface of the component to be
heated. Do not overlap.
-
Do not use for any other purpose than
intended.
-
Ensure that the drum has an open vent to
prevent pressure build up inside
-
Do not use with materials that may react in
an unknown or potentially dangerous
manner when heated
-
Do not use on plastic or other non-metallic
surface. The surface to be heated should be
free from all burrs and sharp edges, weld
spatter, rust, oil, paint, etc.
-
If spillage occurs, unplug the heater and
allow it to cooling. As soon as the drum
heater is cool, clean the area with a solvent
suitable for removing the substance. Do not
allow the material to bake onto the drum
heater.
-
Prior to each use, please check for suspected
damage on heater
Product Design
The products consist of resistance heating wires
which are embedded in polymer insulation
material. The outer layers can be of polymer and
glass-fiber fabric materials. Along the short side
the products are equipped with metal sheets
including hooks for installation with metal
springs or other types of fixations. The products
are designed with an integrated thermostat to
control and maintain the heating power output.
The desired temperature can be regulated via an
external knob on a junction box mounted onto
the surface of the product. The products are
equipped with power supply leads ready for
termination. It is important to determine the
right size of the product. It should be chosen so
it results in no overlapping or shortage when
installed.
For your individual application or product
selection assistance please contact us.
(see last page for contact information)
Product examples
Installation
1.
The product is placed or laid around the
drum to be heated and fastened using
suitable metal springs or other types of
fixations.
2.
The object surface has to be dry and clean
(grease free). It must not be coated!
3.
Ensure that the product is not excessively
stressed or strained during installation.
4.
When installing the product, make sure that
it is in close and even contact with the entire
surface of the object to be heated.
Contactless sections will lead to overheating,
lack
of
performance
and
possible
destruction. When embedded in insulating
material the effects are even more likely to
occur.
5.
The product must never overlap when it is
placed or laid, otherwise the incurring
inadmissible excess temperatures will defect
or destroy it. (see Diagram 1)
6.
The product must not be placed or laid over
sharp edges, corners or burrs. Non-
observance of this provision may lead to
damage of the product.
7.
Ensure that the stated ingress protection (IP
rating) is suitable for the environment of use.
For example, fabric insulated products are of
low IP rating and should only be operated in