THERMOCOAX Isopad IDR-SM Series Operating Instructions Manual Download Page 6

 

__________________________________________________________________________________ 

6 | 

P a g e - S e i t e

 

 

-

 

Do not cross the product onto itself. 

-

 

Ensure  good  contact  between  the  product 
and  the  surface  of  the  component  to  be 
heated. Do not overlap. 

-

 

Do  not  use  for  any  other  purpose  than 
intended. 

-

 

Ensure  that  the  drum  has  an  open  vent  to 
prevent pressure build up inside 

-

 

Do not use with materials that may react  in 
an  unknown  or  potentially  dangerous 
manner when heated 

-

 

Do  not  use  on  plastic  or  other  non-metallic 
surface. The surface to be heated should be 
free  from  all  burrs  and  sharp  edges,  weld 
spatter, rust, oil, paint, etc. 

-

 

If  spillage  occurs,  unplug  the  heater  and 
allow  it  to  cooling.  As  soon  as  the  drum 
heater is cool, clean the area with a solvent 
suitable for removing the substance. Do not 
allow  the  material  to  bake  onto  the  drum 
heater. 

-

 

Prior to each use, please check for suspected 
damage on heater  

Product Design 

 
The products consist of resistance heating wires 
which  are  embedded  in  polymer  insulation 
material. The outer layers can be of polymer and 
glass-fiber fabric materials. Along the short side 
the  products  are  equipped  with  metal  sheets 
including  hooks  for  installation  with  metal 
springs or other types of fixations. The products 
are  designed  with  an  integrated  thermostat  to 
control and maintain the heating power output. 
The desired temperature can be regulated via an 
external  knob  on  a  junction  box  mounted  onto 
the  surface  of  the  product.  The  products  are 
equipped  with  power  supply  leads  ready  for 
termination.  It  is  important  to  determine  the 
right size of the product. It should be chosen so 
it  results  in  no  overlapping  or  shortage  when 
installed. 
For your individual application or product 
selection assistance please contact us.  
(see last page for contact information) 
 
 

     

 

 

     Product examples 

 

Installation 

 
1.

 

The  product  is  placed  or  laid  around  the 
drum  to  be  heated  and  fastened  using 
suitable  metal  springs  or  other  types  of 
fixations.  

2.

 

The  object  surface  has  to  be  dry  and  clean 
(grease free). It must not be coated! 

3.

 

Ensure  that  the  product  is  not  excessively 
stressed or strained during installation. 

4.

 

When installing the product, make sure that 
it is in close and even contact with the entire 
surface  of  the  object  to  be  heated. 
Contactless sections will lead to overheating, 
lack 

of 

performance 

and 

possible 

destruction.  When  embedded  in  insulating 
material  the  effects  are  even  more  likely  to 
occur. 

5.

 

The  product  must  never  overlap  when  it  is 
placed  or  laid,  otherwise  the  incurring 
inadmissible excess temperatures will defect 
or destroy it. (see Diagram 1) 

6.

 

The product must not be placed or laid over 
sharp  edges,  corners  or  burrs.  Non-
observance  of  this  provision  may  lead  to 
damage of the product. 

7.

 

Ensure that the stated ingress protection (IP 
rating) is suitable for the environment of use. 
For example, fabric insulated products are of 
low IP rating and should only be operated in 
dry areas. 

Summary of Contents for Isopad IDR-SM Series

Page 1: ...1235 OMH58614B R12 0 OPERATING INSTRUCTIONS BEDIENUNGSANLEITUNG SILICONE DRUM HEATING BANDS SILIKON FASSHEIZB NDER SERIES SERIE IDR SM AUSF HRUNG VERSION B...

Page 2: ...llation 6 Operation 8 Maintenance and Safety 8 Malfunction and Excessive Strain 9 Heated Media 9 Technical Data 11 DEUTSCH 12 Allgemeine Sicherheitshinweise 12 Allgemeine Produkt Informationen 13 Weit...

Page 3: ...ance with any applicable specification _____________________________________________________________________________________________________ Haftungsauschluss Wichtig Alle Angaben einschlie lich der A...

Page 4: ...rent breaker ELCB or RCD has to be installed for protection purpose This ELCB should represent a tripping current of 30mA To guard against electric shock the products have to be maintained and service...

Page 5: ...tand temperature however depends on the specific operating conditions It may be influenced by the heat conductivity of the materials and media to be heated as well as by the throughput the ambient tem...

Page 6: ...ture can be regulated via an external knob on a junction box mounted onto the surface of the product The products are equipped with power supply leads ready for termination It is important to determin...

Page 7: ...the drum heater tight against the drum see Diagram 2 Diagram 1 An Example of Proper and Improper Installation Diagram 2 Spring Assembly Warning Do not use the terminal cap as a handhold when pulling...

Page 8: ...hen connecting the product the requirements of the standards listed below in General Safety Instructions and Additional Safety Instructions have to be observed The maximum operating and withstand temp...

Page 9: ...ve to be implemented and equipment authorized by the manufacturer When returned please always confirm decontamination status in written form and support this information directly with the returned pro...

Page 10: ...ymbol indicates that the product should be disposed of separately to regular industrial domestic waste It is your responsibility to use this product and other electrical and electronic products only o...

Page 11: ...ilicone Outer Sheath Glass fiber reinforced silicone Dimensions Ordering Information ItemType IDR SM 25 IDR SM 23 IDR SM 15 IDR SM 13 ItemNumber 791428 000 631912 000 118374 000 450166 000 Drum Size t...

Page 12: ...n ELEKTRISCHES BETRIEBSMITTEL Das Produkt ist ein elektrisches Betriebsmittel Um Gefahren durch elektrischen Strom vorzubeugen darf es nur ber einen Fehlerstrom Schutzschalter mit einem Ausl sestrom v...

Page 13: ...ebauten Thermostaten unterschiedlichen Betriebsspannungen unterschiedlichen Leistungsparametern Sie werden zum Aufheizen Temperaturhalten und Ausgleichen von W rmeverlusten an F ssern der Gr sse 110L...

Page 14: ...e keine Kunststoffe oder nicht metallische Oberfl chen Die Oberfl che muss frei von Graten und scharfen Kanten Schwei spritzern Rost l farbe ect sein Falls es zum Auslaufen berlaufen kommen sollte sch...

Page 15: ...hten Sie darauf das die angegebene Schutzart IP Schutzart geeignet f r die Einsatzumgebung ist Zum Beispiel sind gewebe isolierte Produkte mit einer niedrigen Schutzart eingestuft und sollten deshalb...

Page 16: ...r Stellen Sie die gew nschte Temperatur mit dem Drehschalter an der Regeleinheit ein Bild 3 Stellknopf Die maximal zul ssige Temperatur f r den Silikonwerkstoff betr gt 218 C im Dauerbetrieb kurzzeiti...

Page 17: ...turregel und Begrenzungs einrichtungen zu berpr fen und zu dokumentieren Produkte bei denen die Heizleiter sichtbar sind wurden berhitzt Sie sind sofort au er Betrieb zu nehmen und d rfen nicht mehr v...

Page 18: ...sche Richtlinie 2002 95 EC und das deutsche Produktsicherheitsgesetz verlangen dass technische Ausr stung die direkt am oder mit dem Produkt und oder an der Verpackung mit diesem Symbol versehen ist n...

Page 19: ...on Aussenmantel Glasfaserverst rktes Silikon Abmessungen Bestellinformationen Typ IDR SM 25 IDR SM 23 IDR SM 15 IDR SM 13 Artikelnummer 791428 000 631912 000 118374 000 450166 000 Fassgr sse typ 205L...

Page 20: ...__________________________________________________________________________________ 20 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Page 21: ...__________________________________________________________________________________ 21 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Page 22: ...__________________________________________________________________________________ 22 P a g e S e i t e Notes Notizen __________________________________________________________________________________...

Page 23: ...nforme aux norme s ou aux documents normatifs suivants Terms of the Directive s and Approval Data Bestimmungen der Richtlinie und Zulassungsdaten Prescription de la directive et donnees de reference a...

Page 24: ...2012 THERMOCOAX ISOPAD 1235 OMH58614B R12 0 Thermocoax Isopad GmbH Englerstrasse 11 D 69126 Heidelberg Germany Tel 49 0 6221 3043 0 Fax 49 0 6221 3043 956 Mail to isopad info thermocoax com Web www t...

Reviews: