Record the maintenance details in table A in the
appendix of this manual.
7
SPARE PARTS
Before use we advise you to have spare parts in
store, see table B in the appendix of this manual.
8
TECHNICAL INFORMATION
•
See for technical specifications table C in the
appendix of this manual.
9
INSTALLING ACCESSORIES
9.1
Flue (Fig. 4)
The convector heater has a flue connection.
1.
Slide a flue (B) over the connection (C).
2.
Place a rain cover (A) on the end of the flue.
9.2
Diameter of the flue
/i
9.3
Air hose
An air hose may be connected to the exhaust
opening of the convector heater in order to blow
hot air at a large distance from the convector
heater.
Contact your dealer for information about the
maximum length of the exhaust hoses, bends,
manifolds and hose clamps.
9.4
Diameters of exhaust hoses
/i
The convector
heater cannot be
switched off.
34
The magnet valve or valves will
not close.
Close the cock, see fig. 8 (B).
User
Contact your dealer.
Dealer
The convector
heater stops.
35
An overheating problem has
occurred in the convector heater.
Reduce the resistance at the
outlet.
User
Reset the thermostat.
User
Contact the dealer if the error is
repeated.
Dealer
The convector
heater stops
burning. The reset
button lights up.
36
The fuel-supply line or the fuel
filter is leaking.
Check and replace if necessary. User
37
The protective grill of the air inlet
is dirty or clogged.
Clean the grill.
User
38
The heat exchanger is blocked.
Clean the heat exchanger.
Dealer
The convector
heater is producing
white smoke.
39
There is air in the fuel system.
Check the fuel-supply line for
leakage.
User
Burner
malfunction: the
indicator light (red)
is on.
40
There is no fuel.
Check whether there is fuel in
the tank.
User
The photocell is dirty.
Clean the photocell.
User
The photocell is defective.
Replace the photocell.
Dealer
The frequency
controller has a
fault: the indicator
light (red) is on.
41
The motor of the main fan has a
problem.
Reset the frequency controller:
press the button, see fig. 7 (G).
User
Contact the dealer if the error is
repeated.
Dealer
Fault
Cause
Solution
Action
Caution
The flue must be pointed upwards. Do
not let the flue point sideways. An angle
of 45° is acceptable; the length of the
flue should be at least 1000 mm.
Flue (external)
IMAC 4000
Diameter
300 mm
Caution
Check the temperature resistance of the
hose used.
Three-way outlet
IMAC 4000
Diameter
500 mm
Summary of Contents for IMAC 4000
Page 4: ...4 40 020 949 rev 05 2011 IMAC Nederlands 5 English 14 Deutsch 23 Fran ais 33 Espa ol 42 52...
Page 53: ...IMAC 40 020 949 rev 05 2011 53 1 1 1 1 2 2 A B 1 3 3 A B C D E 1 4 1 5 2 2 1 2...
Page 58: ...58 40 020 949 rev 05 2011 IMAC V 6 6 1 i V 1 2 7 I 3 4 5 6 7 8 9 10 7 G 11 12 13 9...
Page 59: ...IMAC 40 020 949 rev 05 2011 59 14 15 16 17 18 8 19 20 21 22 23 24 9 25 2 26...
Page 62: ...62 40 020 949 rev 05 2011 IMAC 10 E www thermobile nl...
Page 68: ...68 40 020 949 rev 05 2011 IMAC...