MAINTENANCE

5.1  

Maintenance table

Use the table in this booklet to record performed

maintenance after each winter season.

5.2  

General

Use the table in this booklet to record performed

maintenance after each winter season.

When the convector heater is to be stored for a

longer period of time:

1.  Switch on the convector heater for three

     minutes. This will protect the fuel pump

     against corrosion.

2.  Make sure the burner head is free from dust

     and deposit.

     A dirty heater head will cause insufficient

     combustion, resulting in the development of

     soot and carbon monoxide and causing

     damage to the burner room.

3.  Close the valve of the fuel supply.

4. Disconnect the power plug.

 

Warning

 

Switch off power during maintenance!

 Hot

 

Do not touch the flue and air outlet!

 

Wait until the flue and the air outlet have

 

cooled down sufficiently before carrying

 

out any maintenance.

5.3  

V-belts (Fig. 7 )

Impression

V-belt tension

13 mm

32,2 N

1. Remove the upper and lower side panels (A).

2. Lower the motor (B) by turning the adjusting

nuts (C).

3. Remove the old V-belts (D).

Install new V-belts in reverse order.

 

Caution

 

Tension the V-belts according to the

 table.

Description yearly check.

Who

Check the fuel pump for leakage, corrosion and dirt.

User

Check the general condition of the pump, fans, ignition, photocell, burner, electrical 

installation and heat exchanger.

Dealer

Check the fuel lines for blockages, corrosion and leakage.

User

Check the fan of the burner for corrosion and dirt.

User

Check the fan for corrosion and dirt.

User

Clean the filters of the fuel pump and the magnet valve.

Dealer

Check the photocell for signs of damage. Make sure the photocell is free from 

dust and deposit.

User

Check the settings of the electrodes.

Dealer

Check the nozzle for dust, etc.

User

Clean the heat exchanger.

Dealer

Clean the inlet/outlet.

User

Check the V-belts.

User

Check the torque of the armatures. The torque value should be 60 Nm.

User

Summary of Contents for IMAC 4000 OIL US

Page 1: ...IMAC 4000 OIL US USER MANUAL...

Page 2: ...2 40 020 950 rev 01 2019 IMAC 4000 US A B C D E F G H I J K O P Q R 1 2 3 4...

Page 3: ...3 40 020 950 rev 01 2019 IMAC 4000 US 6 5 7...

Page 4: ...4 40 020 950 rev 01 2019 IMAC 4000 US Language English 5...

Page 5: ...nty regulations Environment Note The convector heater is made of various metals and synthetic materials The heater also contains electronic parts which must be treated as electronic waste Please conta...

Page 6: ...ignited by the spark between the electrodes The light of the flame that is created will activate the photocell This photocell checks whether a good combustion is brought about In case of poor or no c...

Page 7: ...ches stinging eyes Dizziness disorientation Difficulty breathing feels of being suffocated Proper ventilation air exchange OSHA 29 CFR 1926 57 to support combustion and maintain acceptable air quality...

Page 8: ...nimum distance is 1 m 5 Ensure that the heated air is allowed to flow freely The minimum distance between the outlet and any obstacle is 5 m 6 Check the ventilation surface per kW a surface area of 25...

Page 9: ...ly before carrying out any maintenance 5 3 V belts Fig 7 Impression V belt tension 13 mm 32 2 N 1 Remove the upper and lower side panels A 2 Lower the motor B by turning the adjusting nuts C 3 Remove...

Page 10: ...ect the air flow Reset the convector heater User 9 The combination thermostat is defective Replace the combination thermostat Dealer 10 The frequency controller is in disorder Reset the frequency cont...

Page 11: ...nt and the amount of soot Dealer 26 The settings of the nozzle holder and or the forcer plate are incorrect or dirty Correct the settings of the nozzle holder and the forcer plate Clean the nozzle and...

Page 12: ...es will not close Close the cock see fig 8 B User Contact your dealer Dealer The convector heater stops 35 An overheating problem has occurred in the convector heater Reduce the resistance at the outl...

Page 13: ...ion Check the temperature resistance of the hose used Contact your dealer for information about the maximum length of the exhaust hoses bends manifolds and hose clamps The maximum static pressure in t...

Page 14: ...14 40 020 950 rev 01 2019 IMAC 4000 OIL US English Date Description Maintenance or Failure Action by A...

Page 15: ...15 40 020 950 rev 01 2019 English IMAC 4000 OIL US Date Description Maintenance or Failure Action by...

Page 16: ...16 40 020 950 rev 01 2019 IMAC 4000 OIL US English IMAC 4000 A Fuel filter 41 520 031 B Nozzle C Electrodes block D Set of V belts 41 740 318 2xSPA 2240LW B...

Page 17: ...18 000 24 000 24 000 CFM 10 595 14 715 14 715 Max pressure Pa 400 1000 700 Warm air T C 44 31 43 F 111 88 109 Current A 18 29 29 Nozzle SLW USG hr 6 00 60 S Fan thermostat C 35 F 95 Burner thermostat...

Page 18: ...18 40 020 950 rev 01 2019 IMAC 4000 US...

Page 19: ...care but Thermobile Industries B V cannot be held liable for possible errors in the information or the consequences thereof The information provided herein may not be reproduced and or published in an...

Page 20: ...NDUSTRIES BV Konijnenberg 80 4825 BD Breda Nederland Postbus 3312 4800 DH Breda Nederland Bedrijfsnummer 3502 T 31 0 76 587 34 50 F 31 0 76 587 27 89 info thermobile com www thermobile com 40 020 950...

Reviews: