blown or if you can’t find the problem, you
should contact an electrician.
The voltage powering the ThermoBar is low,
24 volts, and completely safe. However, the
current is quite high, 6-8 ampere. This
means that you cannot use a really long low-
voltage cable between the transformer and
the ThermoBar. If you do, the voltage will be
too low when it reaches the ThermoBar. Our
standard cable delivered with your
ThermoBar is 2 metres but you can change
this to 10 metres, 20 metres
or 30 metres. NB! Avoid using a longer cable
than you need as this will lead to a lower
water temperature and higher energy use. If
you are going to lengthen a 24-volt cable,
you must to get an electrician to do it. NB!
NEVER join with a plug intended for a 230-
volt cable! Hold the plug (not the cable)
when you pull out the 24-volt cable,
otherwise the cable might get damaged.
Our products are recyclable, which is important for ThermoBars sustainability work. When it
has lived its life, recycle your ThermoBar as plastic.
If you have any questions or need any advice, please do not hesitate to contact us at
ThermoBar.