5. The transformer is connected to the power 
source with a regular 230-volt cable that has 
a plug that fits any regular wall socket. 
Splice together with another cable if too 
short to make the length right. Make sure 
any joins are waterproof.  Use a residual-
current circuit breaker in the wall socket if 
the system doesn't have a central residual-
current circuit breaker.  
6. Only the ThermoBar and the low-voltage 
cable should be inside the horses' enclosure. 
7. Make sure the 24-volt plug is pushed all 
the way into the black socket on the 
ThermoBar. 

8. Connect the 230-volt cable to a regular, 
earthed power source. 
9. Fill the trough with water. 
10. 

Don’t let the ThermoBar stand empty in 

cold temperatures as this will cause the 
thermostat to turn the foil heater on. This will 
not damage the trough but it can cause the 
plastic to bulge and buckle a little, and is a 
waste of energy. 
11. The trough can be used all year round, 
even in the summer months, when it is a 
good idea to place it in the shade 

– this will 

help it keep water cool and fresh for even 
longer. 

 

Water temperature 

If you fill your ThermoBar with zero-degree 
water, the heated water will not reach the 
surface until the water at the bottom of the 
trough has reached about 4°C. This can take 
a couple of hours, and if the temperature is 
cold enough a film of ice can form on the 
surface in this time. For this reason, avoid 
filling your ThermoBar with ice-cold water 

when it is really cold. Your ThermoBar has a 
thermostat that turns the foil heater off 
automatically once the water has reached a 
good drinking temperature. 
If you take your horses inside overnight and 
it is very cold, it is a good idea to fill the 
trough in the evening and cover it with an 
insulated lid. Horses like to have a warm 
drink in the mornings, just like we do. 

 

Care  

• It is important to protect the ThermoBar 
from your horses 

– make sure they cannot 

stand in it or damage the inner base with 
their hooves. If the trough is empty and it is 
cold outside, this can cause damage to the 
thermostat. 
• The guarantee is not valid for ThermoBars 
that have evidence of hoof damage inside. 
• The best way of avoiding this is to make 
sure the trough always has water in it when 
it is out in the paddock. 
• It is best if the ThermoBar is not connected 
to electricity if it is standing empty for a 
longer period as the thermostat will last for 
longer. 
Use a soft dish brush or cloth to clean the 
ThermoBar. Avoid scratching the surface of 

the trough and use a good-quality gentle 
cleaning agent. We recommend Hippofix.  
Our carefully selected plastic is tough, can 
handle cold temperatures and is 4-7mm 
thick.  The plastic is soft which means that 
bulges can form in the base or inside walls, 
but this is normal and 

doesn’t affect the 

trough’s functionality. The thermostat that 
regulates the water temperature is in the 
middle of the base of the trough. If it is cold 
and the trough is empty, the thermostat will 
switch the heating system on and heat up 
the trough unnecessarily. As long as the 
trough is empty there is nothing to worry 
about, but it is important that nothing but 
water is ever put in a ThermoBar. 
Never put hay, plastic or any other material 
in the trough. Do NOT use a ThermoBar to 
soak or heat feed! 

 

Electricity safety. 

There is a LED light by the power socket on 
the ThermoBar where the low-voltage cable 
connects. It lights up when power is 
connected to the trough. 

It doesn’t show if 

the thermostat has switched the foil heater 
on or off, however. If the light is not on, 
power is not reaching the trough. It is 

possible that the fuse in the transformer has 
blown. It is a 400 mA fuse that is positioned 
under the cover. These fuses can be found 
at most hardware stores and petrol stations. 
If this doesn’t help, check the fuse for the 
socket that the transformer is connected to. 
If the residual-current circuit breaker has 