Thermo Scientific Thermo Fisher 3900 Series Operating And Maintenance Manual Download Page 18

Section 6 

Maintenance 

 

 

Page 6-1 

 

 

Warning 

Prior to any maintenance or service on this unit, disconnect the 

power cord from power source. Before reattaching  unit to its power source, 
be sure all volatile and flammable cleaners are evaporated and dry. 

 

Avertissement 

Avant d'effectuer toute maintenance ou entretien de cet 

appareil, débrancher  le cordon secteur de la source d'alimentation. Avant 
de reconnecter l'appareil sur le secteur, s'assurer que tous les produits de 
nettoyage  volatiles et inflammables sont complètement  évaporés. 

 
 

The design of the chamber is such that periodic maintenance  is kept to a 
minimum. No lubrication or adjustments of components is needed. 

 

Note 

The unit chamber should be cleaned and disinfected prior to use. 

 

6.1 Cleaning: Periodic cleaning is required. To clean the incubator, 
perform the following steps: 

 

6.1.1. Remove all of the interior parts, if assembled. 

 

6.1.2. Clean the incubator with a mild soap and water solution, 
including all corners. 

 
 

Caution 

DO  NOT  USE spray cleaners that might leak through openings 

and cracks and get on electrical components, or that may contain solvents 
that will harm coatings. DO  NOT  USE chlorine-based  bleaches or 
abrasives, as they will damage  the painted interior. 

 
 

6.1.3. Rinse with distilled water and wipe dry with a soft cloth. 

 

6.1.4. Caution should be used when cleaning around the temperature 
sensors to prevent possible damage to the sensors. 

 

6.2 Disinfecting: Disinfect the incubator on a regular  basis. To disinfect 
the incubator, perform the following steps. 

 

6.2.1. Remove all of the interior parts, if assembled. 

Summary of Contents for Thermo Fisher 3900 Series

Page 1: ...User Manual Thermo Fisher Model 3900 Series Bod Fly Incubators Operating and Maintenance Manual 7003900 January 2013...

Page 2: ...volatile or combustible materials are being heated These units have been tested to the requirements of CAN CSA C22 2 No 61010 1 second edition including Amendment 1 or a later version of the same stan...

Page 3: ...nce must be performed by qualified service personnel Material in this manual is for information purposes only The contents and the product it describes are subject to change without notice Thermo Fish...

Page 4: ...Temperature Protection Signale un d passement de temp rature Indicates AC Power Rep re secteur AC I Indicates the power is ON I Rep re de la position MARCHE de l interrupteur d alimentation O O Indica...

Page 5: ...Preface iv...

Page 6: ...Storing Offset Value for Day Cycle in Memory 4 6 Calibration Offsets for Day Cycle 4 6 Storing Offset Value for Night Cycle in Memory 4 7 Calibration Offsets for Night Cycle 4 7 Settingthe Real Time...

Page 7: ...es and instructions in this manual may be dangerous and illegal General Safety Considerations Your incubator and its recommended accessories have been designed and tested to meet strict safety require...

Page 8: ...e data plate at the rear of the unit Do not modify the power cord provided with the unit If the plug does not fit an outlet have a proper outlet installed by a qualified electrician Avoid damaging the...

Page 9: ...er 2 2 Inspect for concealed loss or damage on the unit itself both interior and exterior If necessary the carrier will arrange for official inspection to substantiate your claim 2 3 Return Shipment S...

Page 10: ...prevent loss of product due to overloading or circuit failure Note Electrical supply to the unit must conform to all national and local electrical codes 3 2 Location When selecting a site for the inc...

Page 11: ...d bottom hooks into the provided slots on the sides of the chamber 3 6 Install Shelf Mounts and Shelves Install shelf mounts from the corner top and bottom hooks into the shelf standard in the chamber...

Page 12: ...e material contained within If temperature rises to the OTL set point the OTL takes control of the peltier unit and prevents the temperature within the incubator from rising further until the problem...

Page 13: ...ual Process Temperature Display Process Setpoint Display Output 1 Active Heating Element On 20 0C 20 0 1 2 3 EZ1 EZ2 Up Arrow Key Down Arrow Key Output 2 Active Output 3 Active Easy Zone Advance Key L...

Page 14: ...Event output 2 Event Timer Factory installed timer internal gLbL Global menu HoUr Hour of day night i CA Calibration offset JC Jump Count JL Jump Loop JS Jump Step Min Minutes SoAH Soak oPEr Operatio...

Page 15: ...LE WILL RUN THE LAST THREE STEPS ARE ENTERING THE NIGHT CYCLE START TIME IN HOURS AND MINUTES AND THE SET POINT WHICH THE NIGHT CYCLE WILL RUN BELOW ARE INSTRUCTIONS ON HOW TO SCROLL THROUGH THE 8 STE...

Page 16: ...ic thermometer neither are supplied with your incubator in the center of the chamber Placing the reference thermometer in the chamber at this stage of operation will allow for calibrating the control...

Page 17: ...s been made allow the unit temperature to stabilize before verifying the reference thermometer matches the setpoint Adjust again if necessary 5 5 Setting the Set Over Limit Temperature Control To set...

Page 18: ...r should be cleaned and disinfected prior to use s 6 1 Cleaning Periodic cleaning is required To clean the incubator perform the following steps 6 1 1 Remove all of the interior parts if assembled 6 1...

Page 19: ...infectants available that are non corrosive and non abrasive and suitable for use on painted surfaces Contact your local Site Safety Officer for detailed information for the proper disinfectants suita...

Page 20: ...ify power cord is properly connected there is no loose or disconnected wiring and all control console devices are firmly seated Do not attempt to access the electrical compartment area unless you are...

Page 21: ...er temperature unstable 1 0 1 may be normal 2 Are the internal and external fans working 3 Is ambient room temperature rapidly changing either door opening or room airflow from heaters or air conditio...

Page 22: ...14 9660510 9660514 9660510 9660514 9660510 Over Temperature Thermostat OTL 1750813 1750813 1750813 1750813 Pilot Light Green 4650554 4650554 4650554 4650554 Pilot Light Red 4650553 4650553 4650553 465...

Page 23: ...its 25 5 x 24 0 x 18 5 in 64 77 x 60 96 x 46 99 cm both units 25 5 x 24 0 x 54 5 in 64 77 x 60 96 x 138 43cm both units 25 5 x 24 0 x 54 5 in 64 77 x 60 96 x 138 43cm both units Capacity 6 55 cubic fe...

Page 24: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G R...

Page 25: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G R...

Page 26: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Page 27: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660514 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Page 28: ...R SWITCH 7850571 LED LIGHT BAR 2 3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 1...

Page 29: ...3 4 1 T1 S1 R1 T1 S1 R1 X1 W1 Y1 W Y L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RE...

Page 30: ...2 L3 K3 J3 L4 K4 98 99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YEL...

Page 31: ...99 CF CD CE B5 D6 D5 WATLOW PM 9660510 RTD SENSOR 6600520 2 3 4 1 2 3 4 1 2 3 4 1 A B C D BROWN BROWN BLUE RED 14G RED 18G BLACK 18G BLACK 14G RED 22G RED 22G BLACK22G BLACK22G YELLOW ORANGE SSR RELA...

Page 32: ...Thermo Fisher Scientific 401 Millcreek Road Marietta Ohio 45750 United States www thermofisher com...

Reviews: