background image

Ordering Information 

Sarasota FD960 

Thermo Fisher Scientific 

Sarasota FD910, FD950, & FD960 User Guide     

A-7

 

Table A–8. 

Sarasota FD960 instrument spares

 

P/N 

Description 

21/107 

Cleaning brush 

ZR20-0117/B 

Box seal ring 

Table A–9. 

Sarasota FD960 installation accessories

 

P/N 

Description 

ZB/MTL/D1 

For use with smart headmounted electronics option with pressure transducer input (set of 3 barriers): 

2x MTL728/28V-300 ohm for density meter power supply and pressure transducer loop power 
1x MTL787S/28V-300 ohm + diode return to power HART signal loop 4–20 mA 

ZB/MTL/D2 

(CM515) 

For use with frequency output option with connection to Sarasota CM515 (set of 3 barriers): 

1x MTL787S/28V-300 ohm + diode return to power density meter 
2x MTL755 dual channel 3V-10 ohm ac barriers 

ZB/MTL/D3 

For use with smart headmounted electronics option without pressure transducer input (set of 2 barriers): 

1x MTL728/28V-300 ohm for density meter power supply 
1x MTL787S/28V-300 ohm + diode return to power HART signal loop 4–20 mA 

ISO/P+F/GH 

Isolation barriers for use with smart headmounted electronics option without pressure transducer input 
(set of 2 barriers): 

1x KFD2-STC3-Ex1 for HART signal loop 4–20 mA 
1x KFD2-SD-Ex1.48 for density meter power; should be used when no earth ground is available or in 
some countries or locations when the device is used in Zone 0 hazardous area 

ISO/MTL 

Isolation barriers for use with smart headmounted electronics option without pressure transducer input 
(set of 2 barriers): 

1x MTL5541 for HART signal loop 4–20 mA 
1 x MTL5525 for density meter power; should be used when no earth ground is available or in some 
countries or locations when the device is used in Zone 0 hazardous area 

Summary of Contents for Sarasota FD910

Page 1: ...Part of Thermo Fisher Scientific Sarasota FD910 FD950 FD960 Liquid Density Meters User Guide P N HB 9135 Revision J...

Page 2: ......

Page 3: ...Sarasota FD910 FD950 FD960 Liquid Density Meters User Guide P N HB 9135 Revision J...

Page 4: ......

Page 5: ...er countries All other trademarks are the property of Thermo Fisher Scientific Inc and its subsidiaries Thermo Fisher Scientific Thermo Fisher makes every effort to ensure the accuracy and completenes...

Page 6: ...This page intentionally left blank...

Page 7: ...and contact information changes Updated specifications Applied standardized format B 01 2007 Revised per ECO 5425 C 09 2007 Revised per ECO 5979 D 04 2008 Revised per ECO 6284 E 03 2009 Revised per EC...

Page 8: ...This page intentionally left blank...

Page 9: ...Pressure Compensation Density Calculation 1 3 Installation 2 1 Mechanical Considerations 2 1 Electrical Considerations 2 2 Hazardous Area Installations 2 2 Marking 2 3 ATEX 2 3 CSA 2 4 Electrical Dat...

Page 10: ...Fisher Scientific Ordering Information A 1 Sarasota FD910 A 1 Sarasota FD950 A 4 Sarasota FD960 A 6 Specifications B 1 Drawings C 1 Health Safety Clearance Form D 1 Toxic Hazardous Substances Tables...

Page 11: ...er in which the substance is applied Read the data sheet applicable to the substance Obey the local orders and instructions Warning Remove all power from the unit before making any connections Electro...

Page 12: ...This page intentionally left blank...

Page 13: ...pharmaceutical industries Ni Span C wetted parts gives the Sarasota FD960 a low temperature coefficient making it the ideal instrument for fiscal or custody transfer applications Typical applications...

Page 14: ...cs a density converter or flow computer to measure line density the density of the fluid inside the density meter The line density can then be used to calculate other variables such as density at refe...

Page 15: ...erefore the resonant frequency The period output from the density meter Period 1 Frequency is used to calculate the density of product within the meter using the transducer calibration data and the st...

Page 16: ...kg m3 C lb ft 3 F TEMPCO temperature coefficient of spool in sec C sec F PRESCO pressure coefficient of the transducer in sec bar sec psi t measured period in sec T measured fixed line temperature in...

Page 17: ...ypass systems above the pipeline but in practice the bypass system is best installed to one side of the main pipeline In addition to mounting orientation the following must be considered prior to inst...

Page 18: ...Zener barriers For intrinsically safe installations zener barriers or galvanic isolators must be used In these cases cable capacitance resistance and inductance must be within the statutory limits or...

Page 19: ...n cases of location in Zone 0 ATEX Category 1 where impact abrasion or other mechanical forces may be expected appropriate methods of protection must be used The Sarasota FD910 FD950 and FD960 density...

Page 20: ...sity meters are marked for use in hazardous areas in accordance with CSA The flameproof option is marked as shown in the label below Figure 2 4 F option At the amplifier terminals 1 2 Ui 30 V li 100 m...

Page 21: ...Installation Hazardous Area Installations Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide 2 5 Flameproof option Vi max 28 Vdc li max 60 mA Pmax 2 0 W CSA...

Page 22: ...This page intentionally left blank...

Page 23: ...ectly installed and grounded earthed where appropriate 1 Connect the density meter to its signal converter or use a suitable bench power supply set to 13 24 Vdc 2 Switch on the power supply and check...

Page 24: ...on that follows Resistance across W and Y Meas1 Resistance across Z and X Meas2 Resistance across X and Y Meas3 Refer to Table 3 1 for resistance and corresponding temperatures By simultaneously measu...

Page 25: ...ponents high pressure pycnometry will be required This is a specialized technique beyond the scope of this manual The sample must be taken from the line carefully at a rate that will not significantly...

Page 26: ...ube This ensures that all bubbles are wiped from the tubes 2 Allow the temperature to stabilize Then record the density reading and temperature obtained Compare the density value with the water data i...

Page 27: ...been designed so that in general no maintenance is required Maintenance is limited to periodically checking the accuracy of the meter via sample fluids checking the PRT output and cleaning the meter I...

Page 28: ...directly Process Instruments 12320 Cardinal Meadow Dr Suite150 Sugar Land TX 77478 USA 1 800 437 7979 Unit 702 715 7 F Tower West Yonghe Plaza No 28 Andingmen East Street Beijing 100007 CHINA 86 10 8...

Page 29: ...nsult Thermo Fisher H Smart headmounted electronics Provides HART compatible 4 20 mA output and for use of optional local display accepts 4 20 mA input from pressure transducer for pressure compensati...

Page 30: ...available with smart headmounted electronics option M Wetted parts traceability to EN 10204 Type 3 1 N NACE Conformance All wetted parts suitable for sour gas service NACE specification MR 01 75 T Tra...

Page 31: ...CM515 set of 3 barriers 1x MTL787S 28V 300 ohm diode return to power density meter 2x MTL755 dual channel 3V 10 ohm ac barriers ZB MTL D3 For use with smart headmounted electronics option without pre...

Page 32: ...16 5 Hastelloy C276 Class 150 lb RF flanges F2 1 ANSI B16 5 Hastelloy C276 Class 300 lb RF flanges A2 1 ANSI B16 5 Hastelloy C276 Class 600 lb RF flanges D BS4504 PN40 Hastelloy C276 DN25 RF flanges F...

Page 33: ...quency output option with connection to Sarasota CM515 set of 3 barriers 1x MTL787S 28V 300 ohm diode return to power density meter 2x MTL755 dual channel 3V 10 ohm ac barriers ZB MTL D3 For use with...

Page 34: ...5 316L SS Class 300 lb RF flanges F1 1 ANSI B16 5 Class 300 DUPLEX flanges1 A0 1 ANSI B16 5 316L SS Class 600 lb RF flanges A1 1 ANSI B16 5 Class 600 DUPLEX flanges1 D BS4504 PN40 DN25 213L SS RF fla...

Page 35: ...m ac barriers ZB MTL D3 For use with smart headmounted electronics option without pressure transducer input set of 2 barriers 1x MTL728 28V 300 ohm for density meter power supply 1x MTL787S 28V 300 oh...

Page 36: ...This page intentionally left blank...

Page 37: ...ensity range 0 2100 kg m3 0 131 1 lb ft 3 Installation No instrument or pipework supports required Standard Vertical installation Optional Horizontal installation Pressure effect corrected 0 003 kg m3...

Page 38: ...4 wire PT100 H option headmounted electronics Analog 4 20 mA related to density or density derived variable HART protocol Power supply F option frequency output 13 28 Vdc 10 mA average peak 18 mA H o...

Page 39: ...ility Compliant EN 61326 1997 Pressure Equipment Direct 97 23 EC Category III Low Voltage Directive Compliant Safe area use As standard BS EN ISO 15156 NACE MR0175 Conformance Sarasota FD910 and FD950...

Page 40: ...This page intentionally left blank...

Page 41: ...y excluded Therefore the drawings within this guide may not be exact duplicates of the original drawings Note Drawings in this manual are included for reference only and may not be the current version...

Page 42: ...Drawings C 2 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 1 Installation drawing horizontal methods sheet 1 of 1...

Page 43: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 3 Figure C 2 Installation drawing vertical methods sheet 1 of 1...

Page 44: ...Drawings C 4 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 3 AD_5037 Dimensional drawing sheet 1 of 1...

Page 45: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 5 Figure C 4 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 1 of 9...

Page 46: ...Drawings C 6 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 5 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 2 of 9...

Page 47: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 7 Figure C 6 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 3 of 9...

Page 48: ...Drawings C 8 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 7 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 4 of 9...

Page 49: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 9 Figure C 8 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 5 of 9...

Page 50: ...Drawings C 10 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 9 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 6 of 9...

Page 51: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 11 Figure C 10 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 7 of 9...

Page 52: ...Drawings C 12 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific Figure C 11 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 8 of 9...

Page 53: ...Drawings Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide C 13 Figure C 12 AD_6502 Wiring diagrams barrier non hazardous safe area options for Sarasota density meters sheet 9 of 9...

Page 54: ...This page intentionally left blank...

Page 55: ...Sarasota FD910 FD950 FD960 User Guide D 1 Appendix D Health Safety Clearance Form The Health Safety COSHH Clearance form can be found on the following page Failure to return this form may result in t...

Page 56: ...contact with the equipment must be declared Chemical names list all Precautions to be taken when handling these substances list all Action to be taken in the event of human contact or spillage Additio...

Page 57: ...ic Sarasota FD910 FD950 FD960 User Guide E 1 Appendix E Toxic Hazardous Substances Tables The English and Chinese versions of the Toxic Hazardous Substances tables for the density meters can be found...

Page 58: ...Toxic Hazardous Substances Tables E 2 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific...

Page 59: ...Toxic Hazardous Substances Tables Thermo Fisher Scientific Sarasota FD910 FD950 FD960 User Guide E 3...

Page 60: ...Toxic Hazardous Substances Tables E 4 Sarasota FD910 FD950 FD960 User Guide Thermo Fisher Scientific...

Page 61: ...Thermo Fisher Scientific 81 Wyman Street P O Box 9046 Waltham Massachusetts 02454 9046 United States www thermofisher com...

Reviews: