Thermo Scientific NAPCO 6506 Operator'S Manual Download Page 6

1

INTRODUCTION

Your satisfaction and safety are important to

Thermo

 and a complete understanding of this unit

is necessary to attain these objectives.

As the user of this apparatus, you have the
responsibility to understand the proper function
and operational characteristics of your oven. This
instruction manual should be thoroughly read and
all operators given adequate training before
attempting to place this unit in service. Awareness
of the stated cautions and warnings, and
compliance with recommended operating
parameters -- together with maintenance
requirements -- are important for safe and
satisfactory operation. The unit should be used
for its intended application; alterations or
modifications will 

VOID THE WARRANTY.

WARNING

AS A ROUTINE LABORATORY PRECAUTION,
ALWAYS WEAR SAFETY GLASSES WHEN
WORKING WITH THIS APPARATUS.

This product is not intended, nor can it be used,
as a sterile or patient connected device. In
addition, this apparatus is not designed for use in
Class I, II or III locations as defined by the National
Electrical Code.

UNPACKING AND DAMAGE

Save all packing material until unit is put into
service. This merchandise was carefully packed
and thoroughly inspected before leaving our
factory.

Responsibility for safe delivery was assumed by
the carrier upon acceptance of the shipment;
therefore, claims for loss or damage sustained in
transit must be made upon the carrier by the
recipient as follows:

1.

Visible Loss or Damage:

  Note any external

evidence of loss or damage on the freight bill,
or express receipt, and have it signed by the
carrier's agent. Failure to adequately describe
such external evidence of loss or damage may
result in the carrier's refusing to honor your
damage claim. The form required to file such
claim will be supplied by the carrier.

2.

Concealed Loss or Damage:

  Concealed

loss or damage means loss or damage which
does not become apparent until the
merchandise has been unpacked and
inspected. Should either occur, make a written
request for inspection by carrier's agent within
fifteen (15) days of the delivery date; then file
a claim with the carrier since the damage is
the carrier's responsibility.

If you follow the above instructions carefully, we
will guarantee our full support of your claim to be
compensated for loss or concealed damage.

DO NOT -- FOR ANY REASON -- RETURN THIS
UNIT WITHOUT FIRST OBTAINING
AUTHORIZATION. In any correspondence to

Thermo,

 please supply the nameplate data,

including catalog number and serial number.

Summary of Contents for NAPCO 6506

Page 1: ...07 5851 Operator s Manual NAPCO Vacuum Oven Thermo Fisher Scientific 401 Millcreek Road Box 649 Marietta Ohio 45750 USA Phone 740 373 4763 Toll Free 800 438 4851 FAX 740 373 4189 ManualP N3177872 Rev...

Page 2: ...TIFICMAKESNOREPRESENTATIONSOR WARRANTIES WITH RESPECT TO THIS MANUAL IN NO EVENT SHALL THERMO BE LIABLE FOR ANY DAMAGES DIRECT OR INCIDENTAL ARISINGOUTOFORRELATEDTOTHEUSEOFTHIS MANUAL For repair infor...

Page 3: ...9 99 4 05 6 06 9 09 11 10 11 12 Update parts list for new kit s manual manufacturelocation updated elec specs to UL report Corrected 3174760 to 3175318 sw Align correct part numbers in parts list Cor...

Page 4: ...tion and Adjustment 2 Specifications 2 Explanation of Controls 3 Temperature Adjustment 4 Vacuum Operation 4 Periodic Maintenance 5 Door Gasket Compatibility Chart 6 Maintenance of Stainless Steel 7 R...

Page 5: ......

Page 6: ...se was carefully packed and thoroughly inspected before leaving our factory Responsibility for safe delivery was assumed by the carrier upon acceptance of the shipment therefore claims for loss or dam...

Page 7: ...Place shelves in chamber with lip up NOTE HEATERS ARE LOCATED ON BOTTOM OF CHAMBER PLACING AN ITEM DIRECTLY ON THE CHAMBER FLOOR MAY CAUSE OVERHEATING OF THE ITEM Install Thermometer A thermometer wel...

Page 8: ...Indicates chamber vacuum in inches of mercury 6 Hose Connections Used for connecting minimum 1 4 vacuum tubing between oven and vacuum pumping systems or other apparatus 7 Valves Used for evacuating c...

Page 9: ...hes of mercury per cubic foot per 24 hours at 29 to 26 inches of mercury Vacuum Sealing Agents High vacuum silicone grease is often necessary to provide a proper seal at tubing connections valve conne...

Page 10: ...on the right side of the oven is out of alignment it can be adjusted in the same manner 3 Gaskets should be checked periodically for hardening shrinking deterioration or other signs of wear It is advi...

Page 11: ...FAIR VERY GOOD Aldehydes FAIR POOR POOR GOOD Alkalis FAIR GOOD GOOD VERY GOOD Amines POOR POOR GOOD Animal Oils EXCELLENT VERY GOOD GOOD Esters Alkyl Phosphate Skydrol POOR POOR GOOD Esters Aryl Phos...

Page 12: ...leaned regularly with mild soapy water and rinsed with distilled water Always thoroughly dry the chamber after cleaning IMPORTANT IF IT IS NECESSARY TO USE THE FOLLOWING CHEMICALS LIMIT THE EXPOSURE T...

Page 13: ...5 Oxalic Acid 2 to 5 in warm water Swab solution on surface allowing it to remain until rust is loosened Immediately flush with copious amounts of clean water 6 A mixture of 20 nitric acid and 1 5 hy...

Page 14: ...inishes Liquid NuSteel Rub with dry cloth Use small amount of cleaner Use in direction of polish lines on No 4 polished finish May scratch No 2 mill and Nos 7 and 8 polished finishes Paste NuSteel DuB...

Page 15: ...ag 57 Rub with dry cloth Use small amount of cleaner Use in direction of polish lines on No 4 polished finish May scratch No 2 mill and Nos 7 and 8 polished finishes Hard Water Spots and Scale Vinegar...

Page 16: ...5 Door Gasket Silicone 3173927 Door Gasket Buna N 3174683 Door Gasket Viton 3167059 DoorAssembly 3166984 DoorLatchAssembly 3167255 Foot Leveler Kit 3174674 SiliconWindowGasket 3173926 Buna NWindow Gas...

Page 17: ...12 WIRING DIAGRAMS 120 VOLT WIRING DIAGRAM...

Page 18: ...13 240 VOLT WIRING DIAGRAM...

Page 19: ...warranty period The Technical Services Department must give prior approval for return of any components or equipment At Thermo s option all non conforming parts must be returned to Thermo Fisher Scie...

Page 20: ...this warranty Replacement or repair of components parts or equipment under this warranty shall not extend the warranty to either the equipment or to the component part beyond the original warranty pe...

Page 21: ......