11
i)
Resolder the wires as identified or marked in Step (e).
j)
Reinstall plastic housing and secure with four screws.
k) While holding the mixing platform to keep it from turn-
ing, secure the platform to the counterweight assem-
bly. If the mixing surface is in good condition, reapply
it to the mixing platform.
l)
Reconnect mixer to power supply.
To Replace Damper Springs:
a) Disconnect mixer from power supply.
b) Peel off the mixing surface disc. Hold the mixing plat-
form to keep from turning and remove the platform
from the counterweight assembly.
c) Turn mixer upside down and remove four screws
securing plastic housing.
d) Turn mixer upright and remove housing.
e) Remove defective damper springs.
f)
Install new damper springs.
g) Reinstall plastic housing and secure with four screws.
h) While holding the mixing platform to keep it from turn-
ing, secure the platform to the counterweight assem-
bly. If the mixing surface is in good condition, reapply
it to the mixing platform.
i)
Reconnect mixer to power supply.
To Replace Mixing Surface Disc:
a) Disconnect mixer from power supply.
b) Peel off old mixing surface disc and clean the bonding
area.