Appendix 1 SCREEN FLOW DIAGRAMS, Page A1-6
Thermo Fisher Scientific
APPENDIX 1 LCD SCREENS
A1.2 Screen types and identities
A1.2.1 Screen type
Screens are classified according to their function as follows:
MENU
Offers selection of lower order screens
GATEWAY
Access screens for station or channel setup
ENTRY/EDIT
Data is entered or edited via these screens
RESULTS
Displays status or results measured or calculated by flowmeter
WAVEFORM Displays
ultrasonic
waveforms
The screen type is indicated for each display screen and is shown on the Screen
Organisation Chart above.
A1.2.2 Screen identities
•
The flowmeter start up screen has no number and is the STATION HOME screen
•
Each configured channel (minimum 1, maximum 4) has a CHANNEL HOME screen
•
All menu, entry/edit, results and waveform screen numbers associated with the
station setup are prefixed ‘S’ and those associated with the channel setup are
prefixed ‘C’.
•
All screens associated with the station setup can return directly to the STATION
HOME screen via the Station soft key
•
All screens associated with each channel setup can return directly to the appropriate
CHANNEL HOME screen via the appropriate Channel soft key
•
Screens below the HOME screens have a unique identification number in the top left
corner that corresponds to the Screen Organisation Chart and Index.
•
Sample screens for each display are presented in numerical order. Note: 2 digit
screen numbers are a sub-set of single digit screen numbers. Similarly, 3 digit screen
numbers are a sub-set of 2 digit screen numbers (eg C2; C21; C211)
•
Station setup should precede channel setup
A1.2.3 Soft key function
The 4 keys immediately beneath the screen display have a function which varies according to
the screen. The active ‘soft key’ function is indicated on the screen immediately above the
corresponding key.
Soft key functions include:
Station
returns user to STATION HOME screen
Channel1
returns user to CHANNEL 1 HOME screen
Channel2
(if configured) returns user to CHANNEL 2 HOME screen. Similarly
for Channel 3 and 4
Text On and Text Off (only available for alphanumeric data entry/edit) turns alphanumeric
mode on and off
Clone
function available as a short cut when path configurations are similar
Rebuild
to confirm entry/modification of path configurations