background image

5

4" X 4"

Model Number

HP130915

HP130910-33

HP130914

Overall Dimensions in. (cm)

Width

5.0” (12.7 cm)

5.0” (12.7 cm)

5.0” (12.7 cm)

Height

3.6" (9.7 cm)

3.6" (9.7 cm)

3.6" (9.7 cm)

Depth

10.0" (25.4 cm)

10.0" (25.4 cm)

10.0" (25.4 cm)

Weight lbs (kg)

7.0 lbs (3.2 kg)

7.0 lbs (3.2 kg)

7.0 lbs (3.2 kg)

Top Plate

Width

4.25" (10.8 cm)

4.25" (10.8 cm)

4.25" (10.8 cm)

Height

1.0" (2.5 cm)

1.0" (2.5 cm)

1.0" (2.5 cm)

Depth

4.25" (10.8 cm)

4.25" (10.8 cm)

4.25" (10.8 cm)

Electrical Ratings

Volts

120

220-240

100

Amps

3.2

1.7

3.8

Watts

385

420

385

Freq.

60

50/60

50/60

Phase

1

1

1

Max. Temp. °F (°C)

1004°F (540°C)

1004°F (540°C)

1004°F (540°C)

7" X 7"

Model Number

HP131225

HP131220-33HP131224

Overall Dimensions in. (cm)

Width

8.2” (20.8 cm)

8.2” (20.8 cm)

8.2” (20.8 cm)

Height

3.8” (9.7 cm)

3.8” (9.7 cm)

3.8” (9.7 cm)

Depth

13.0” (33.0 cm)

13.0” (33.0 cm)

13.0” (33.0 cm)

Weight lbs (kg)

11.0 lbs (5.0 kg)

11.0 lbs (5.0 kg)

11.0 lbs (5.0 kg)

Top Plate

Width

7.25” (18.4 cm)

7.25” (18.4 cm)

7.25” (18.4 cm)

Height

1.0" (2.5 cm)

1.0" (2.5 cm)

1.0" (2.5 cm)

Depth

7.25” (18.4 cm)

7.25” (18.4 cm)

7.25” (18.4 cm)

Electrical Ratings

Volts

120

220-240

100

Amps

8.8

4.8

10.7

Watts

1060

1150

1070

Freq.

60

50/60 50/60

Phase

1

1

1

Max. Temp. °F (°C)

1004°F (540°C)

1004°F (540°C)

1004°F (540°C)

10" X 10"

Model Number

HP131535

HP131530-33HP131534

Overall Dimensions in. (cm)

Width

11.38” (28.9 cm)

11.38” (28.9 cm)

11.38” (28.9 cm)

Height

4.0” (10.2 cm)

4.0” (10.2 cm)

4.0” (10.2 cm)

Depth

16.25” (41.3 cm)

16.25” (41.3 cm)

16.25” (41.3 cm)

Weight lbs (kg)

13.75 lbs. (6.24 kg)

13.75 lbs. (6.24 kg)

13.75 lbs. (6.24 kg)

Top Plate

Width

10.5” (26.7 cm)

10.5” (26.7 cm)

10.5” (26.7 cm)

Height

1.0" (2.5 cm)

1.0" (2.5 cm)

1.0" (2.5 cm)

Depth

10.5" (26.7 cm)

10.5" (26.7 cm)

10.5" (26.7 cm)

Electrical Ratings

Volts

120

220-240

100

Amps

11.7

6.4

11.2

Watts

1410

1530

1125

Freq.

60

50/60 50/60

Phase

1

1

1

Max. Temp. °F (°C)

750°F (400°C)

750°F (400°C)

750°F (400°C)

Specifications

Summary of Contents for Cimarec HP130910-33

Page 1: ... PARTS LIST Model Top Plate Size Voltage HP130914 4x4 100 HP130915 4x4 120 HP130910 33 4x4 220 240 HP131224 7x7 100 HP131225 7x7 120 HP131220 33 7x7 220 240 HP131534 10x10 100 HP131535 10x10 120 HP131530 33 10x10 220 240 1 LT1312X1 10 28 09 ...

Page 2: ...Installation 10 Unpacking 10 Installation 10 Operation 11 Setting the Temperature 11 To Achieve Fast Heat Up of Large Volumes 11 Heating Small Volumes 12 Heating Metal Vessels and Sand Baths 12 Maintenance 13 General Cleaning Instructions 13 Troubleshooting 14 Error Codes 14 Exploded Views 15 Wiring Diagram 21 Replacement Parts 22 Accessories 22 Ordering Procedures 23 Warranty 24 2 Table of Conten...

Page 3: ...ld reach lev els in excess of the maximum temperature This manual contains important operating and safety information The user must carefully read and under stand the contents of this manual prior to the use of this equipment Warnings To avoid electrical shock always 1 Use a properly grounded electrical outlet of correct voltage and current handling capacity 2 Disconnect from the power supply prio...

Page 4: ...f cord is repeatedly loos ened it is recommended to purchase the cord retaining clip part number AY1313X1 or AY1313X2 listed in the Replacement Parts sec tion of this manual 7 Do not remove or modify grounded power plug Use only properly grounded outlets to avoid shock hazard 8 Use appropriate hand and eye protection when handling hazardous chemicals 9 Gross weight of items placed on top of hot pl...

Page 5: ... Weight lbs kg 11 0 lbs 5 0 kg 11 0 lbs 5 0 kg 11 0 lbs 5 0 kg Top Plate Width 7 25 18 4 cm 7 25 18 4 cm 7 25 18 4 cm Height 1 0 2 5 cm 1 0 2 5 cm 1 0 2 5 cm Depth 7 25 18 4 cm 7 25 18 4 cm 7 25 18 4 cm Electrical Ratings Volts 120 220 240 100 Amps 8 8 4 8 10 7 Watts 1060 1150 1070 Freq 60 50 6050 60 Phase 1 1 1 Max Temp F C 1004 F 540 C 1004 F 540 C 1004 F 540 C 10 X 10 Model Number HP131535 HP13...

Page 6: ...the average actual temperature of a 5 0 C 2 diameter of setting area at the center of the top plate setpoint 100 C Top plate temperature was verified with an infrared camera mounted approx 26 above the center of the top plate surface temperature accuracy at the edges of the top plate may vary from the stated accuracy Top Plate Size Max Recommended Flask Size Max Weight on Top Plate 4 x 4 1 liter 1...

Page 7: ...uations and flicker EN 61326 1 Electrical equipment for measurement control and laboratory use Part I General Requirements Safety EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part I General Requirements EN 61010 2 010 Part II Particular requirements for laboratory equipment for the heating of materials per the provisions of the Electromagnetic ...

Page 8: ...d the 5 C through 400 C models on the 10 x 10 models The temperature is controlled at the plate surface by an internal sensor The top plate on the Cimarec units is solid ceramic and is suitable for use with glass or metal vessels Your Cimarec hot plate may be used for general purpose heating applications including sample preparation heat ing reagents melting paraffin warming resinous chemi cals co...

Page 9: ...C depending on the model The top plate surface temper atures are calibrated and verified at the factory using the latest in infrared temperature measurement The measurements are made with an infrared camera mounted approximately 26 above the top surface of the hot plate If the temperature measurement of the ceramic top is made with measurement devices other than infrared the error of the measuring...

Page 10: ...e following items are included in the shipment Cimarec Hot Plate Cord Adapter 100V models only Knob Operator s Manual If any of these items are missing from the carton contact customer service Installation Set the unit on a flat stable surface at least 12 away from combustible materials and plug the cordset into a proper ly grounded electrical outlet of correct voltage and current handling capacit...

Page 11: ...nate between HOT and OFF and the HOT TOP light will flash until the top surface has cooled to 50 C Nothing will be displayed on the screen when the unit has been cooled down and the knob is turned to OFF To Achieve Fast Heat up of Large Volumes If you are heating larger volumes faster heating can be achieved by turning the heat control knob to maximum temperature until the solution starts to heat ...

Page 12: ... life of the hot plate OPERATION Note The solution temperature is approxi mately 25 cooler than the hot plate surface temperature Note If you allow the top plate to reach the maximum temperature of 540 C while preheating and then turn the control down to a setpoint less than 200 C the temperature of the top will drop rapidly to 200 C Because of the natu ral cooling characteristics of ceramic the t...

Page 13: ...General Cleaning Instructions Wipe exterior surfaces with lightly dampened cloth con taining mild soap solution 13 Maintenance ...

Page 14: ...etect Cause Solution E01 Thermocouple Thermocouple not connected Replace element Call Tech Service out of range assembly attached to thermocouple Thermocouple open circuit E02 Excessive heat up time Thermocouple short circuit Remove short Call Tech Service Failure of element Replace element assembly attached to thermocouple Failure of element circuit Replace Element Replace Control Board ...

Page 15: ...15 Exploded Views 4x4 Exploded View 5 6 7 1 2 220 240V Models Only 9 8 9 11 Optional Accessory Ref A 10 12 4 3 ...

Page 16: ...16 EXPLODED VIEWS 13 15 Note routing of leads and thermocouple 16 Number located this side 17 14 4x4 Exploded View Top Plate ...

Page 17: ...17 EXPLODED VIEWS 4 5 6 7 1 2 220 240V Models Only 8 9 Optional Accessory Ref A 10 3 12 11 7x7 Exploded View ...

Page 18: ...18 EXPLODED VIEWS 13 15 Note routing of leads and thermocouple 16 Number located this side 17 14 7x7 Exploded View Top Plate ...

Page 19: ...4 3 5 6 7 1 2 220 240V Models Only 8 9 11 Optional Accessory Ref A 10 12 19 EXPLODED VIEWS 10x10 Exploded View ...

Page 20: ...20 10x10 Exploded View Top Plate 13 15 Note routing of leads and thermocouple 16 Number located this side 17 ...

Page 21: ...21 Wiring Diagram 21 ...

Page 22: ... AY1313X1 Retaining Clip 100V 120V 12 AY1313X2 AY1313X2 AY1313X2 Retaining Clip 220 240V 13 JNX33 JNX35 Lower Insulation 14 JNX34 JNX36 JNX38 Upper Insulation 15 ELX41 ELX44 ELX47 Heating Element 120V w thermocouple 15 ELX42 ELX45 ELX48 Heating Element 100V w thermocouple 15 ELX43 ELX46 ELX49 Heating Element 220 240V w thermocouple 16 540 0033 710 0117 719 0073 Ceramic Top 17 EL1310X1 EL1313X1 EL1...

Page 23: ...c dealer from whom you purchased this unit or can be obtained promptly from the factory When service or replacement parts are needed we ask that you check first with your dealer If the dealer cannot handle your request then contact our Customer Service Department at 563 556 2241 or 800 553 0039 Prior to returning any materials please contact our Customer Service Department for a Return Materials A...

Page 24: ...suse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or third party or iii use of replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific prod ucts Heating elements because of their susceptibility to overheating and contaminati...

Reviews: