13 Month Limited Warranty

for United States and

Canada

This Thermo Scientific product is warranted to be free of defects in materials and workmanship for 13 months
from the first to occur of (i) the date the product is sold by the manufacturer or (ii) the date the product is
purchased by the original retail customer (the “Commencement Date”). Except as expressly stated above, the
MANUFACTURER MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, WITH RESPECT TO THE
PRODUCTS AND EXPRESSLY DISCLAIMS ANY AND ALL WARRANTIES, INCLUDING BUT NOT LIMITED
TO, WARRANTIES OF DESIGN, MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE. 

An authorized representative of the manufacturer must perform all warranty inspections. In the event of a defect 
covered by the warranty, we shall, as our sole obligation and exclusive remedy, provide free replacement parts 
to remedy the defective product. In addition, for products sold within the continental United States or Canada, 
the manufacturer shall provide free labor to repair the products with the replacement parts. 

The warranty provided hereunder shall be null and void and without further force or effect if there is any (i) repair 
made to the product by a party other than the manufacturer or its duly authorized service representative, (ii) 
misuse (including use inconsistent with written operating instructions for the product), mishandling, 
contamination, overheating, modification or alteration of the product by any customer or third party or (iii) use of 
replacement parts that are obtained from a party who is not an authorized dealer of Thermo Scientific products. 

Heating elements, because of their susceptibility to overheating and contamination, must be returned to the 
factory and if, upon inspection, it is concluded that failure is due to factors other than excessive high temperature
or contamination, the manufacturer will provide warranty replacement. As a condition to the return of any 
product, or any constituent part thereof, to the factory, it shall be sent prepaid and a prior written authorization 
from the manufacturer assigning a Return Materials Number to the product or part shall be obtained. 

IN NO EVENT SHALL THE MANUFACTURER BE LIABLE TO ANY PARTY FOR ANY DIRECT, INDIRECT, 
SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, OR FOR ANY DAMAGES RESULTING FROM 
LOSS OF USE OR PROFITS, ANTICIPATED OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH
THE SALE, USE OR PERFORMANCE OF ANY PRODUCTS, WHETHER SUCH CLAIM IS BASED ON 
CONTRACT, TORT (INCLUDING NEGLIGENCE), ANY THEORY OF STRICT LIABILITY OR REGULATORY 
ACTION. 

For the name of the authorized Thermo Scientific product dealer nearest you or any additional information, 
contact us. 

www.thermofisher.com 1-866-9-THERMO

1

6

Summary of Contents for 25LCEETSA

Page 1: ...Refrigerators and Freezers Installation and Operation Manual 327202H01 Rev B 25LCEETSA...

Page 2: ...2015 Thermo Fisher Scientific All rights reserved...

Page 3: ...tics 5 Temperature Ranges 5 Electrical Requirements 5 Environmental Operating Conditions 5 Installation 6 Location 6 Wiring 6 Leveling 6 Door Seal 6 Rearranging the Shelves 7 Operation 11 Changing the...

Page 4: ...Freezer The model features Large Capacity approximately 16 3 cu ft in the refrigerator compartment 6 9 cu ft in the freezer compartment Cooling by forced air circulation Automatic defrost Separate fre...

Page 5: ...immediately hazardous situation which if not avoided may result in minor to moderate injury No Symbol CAUTION Without Safety Alert Symbol indicates a situation that may result in property damage Shoc...

Page 6: ...ators 1 C to 12 C Freezers 12 C to 20 C These are not considered medical devices and have therefore not been registered with a medical device regulatory body e g FDA that is it has not been evaluated...

Page 7: ...the packing materials and immediately report the damage to the carrier Do not return goods to the manufacturer without written authorization When submitting a claim for shipping damage request that t...

Page 8: ...s 10 60 Hz 11 6 Amps Environmental Operating Conditions POLLUTION DEGREE 2 INSTALLATION CATEGORY II ALTITUDE 2000 Meters MSL Mean Sea Level HUMIDITY 80 maximum non condensing ELECTRICAL SUPPLY 120V 60...

Page 9: ...ull the paper strip from the outside You should feel some resistance 4 Repeat this test at 4 inch intervals around the door If the door does not seal properly replace the gasket 5 Check the freezer do...

Page 10: ...e 1 Remove all items from the shelf 2 Tilt the shelf up at the front 3 Lift the shelf up at the back and bring the shelf out To Replace 1 While tilting the shelf up insert the top hook at the back of...

Page 11: ...locate Slide in the bin just above the molded door supports and push down The bin will lock in place The snugger helps prevent tipping spilling or sliding of small items stored on the door shelf Grip...

Page 12: ...Lift the basket so that it is out of all 6 slide bracket tabs 4 Tilt the basket and lift out of the drawer When replacing the deep full width basket Tilt the basket back and lower it down into the dr...

Page 13: ...he slide When replacing the basket make sure that the wire tabs and wire hooks on the sides of the basket go into the slots in the top of the upper basket slides NOTE Always be sure to fully close thi...

Page 14: ...move it now The temperature control can be adjusted between 0 to 9 0 being OFF and 9 being the coldest temperatures by tapping the colder and warmer buttons on the temperature control Setting either o...

Page 15: ...o significant frost build up in the freezer compartment An automatic 45 minute defrosting period is initiated every 12 hours of compressor run time During a defrost period a thermostat will turn the d...

Page 16: ...he light shield grasp the shield at the back and pull out to release the tabs at the back 3 Rotate the shield down and then forward to release the tabs at the front of the shield 4 After replacing wit...

Page 17: ...n scratch and weaken the paint finish Cleaning the inside To help prevent odours leave an open box of baking soda in the refrigerator and freezer compartments Unplug the refrigerator before cleaning I...

Page 18: ...e door seal Warm product recently loaded in unit Allow ample time to recover from loading warm product Power supply Check for proper voltage to the unit If there is no voltage to the unit call an elec...

Page 19: ...presentative ii misuse including use inconsistent with written operating instructions for the product mishandling contamination overheating modification or alteration of the product by any customer or...

Page 20: ...gfallen finden Sie unter www thermo com Conformit WEEE Questo prodotto deve rispondere alla direttiva dell Unione Europea 2002 96EC in merito ai Rifiuti degli Apparecchi Elettrici ed Elettronici WEEE...

Page 21: ...can be found on the dataplate attached to the equipment If available please provide the date purchased the source of purchase manufacturer or specific agent rep organization and purchase order number...

Page 22: ...Thermo Fisher Scientific Inc 275 Aiken Road Asheville NC 28804 United States www thermofisher com 327202H01 Rev B...