Viewing Prompt and

Display Screens

1. Press the ON key to 
turn the unit ON.
2. Press the SELECT key 
repeatedly to show the 
prompt and display 
screens.
The prompt and display screens will appear in the order shown 
below:

[ALr]

 Alarm codes if present. If no codes exist this

screen will not appear.

[CYCLS] 

CYCLE SENTRY or Continuous mode 

prompt screen. [YES] - CYCLE SENTRY; 
[no] = Continuous

[dIS]*

 Discharge air temperature as measured by 

the discharge temperature sensor.

[coL]* 

Evaporator coil temperate as measured by 

the evaporator coil temperature sensor.

[tLH]

 Total amount of time in hours the unit has been 

turned ON with the keypad On key (if enabled).

[EnH]

 Total amount of time in hours the diesel 

engine has run.

[ELH]

 Total amount of time in hours the electric 

motor has run (on units equipped with 
Electric Standby).

[Hr4] 

Total accumulated hours on hourmeter 4 

(if enabled).

[Hr5]

 Total accumulated hours on hourmeter 5 

(if enabled).

[Hr6]

 Total accumulated hours on hourmeter 6 

(if enabled).

[oIL]*

 Diesel engine oil pressure.

[Ent]*

 Diesel engine coolant temperature.

[rPn]*

 Diesel engine RPM.

[bAt]*

 Battery voltage of the unit battery.

[bLIt]

 Backlight select (allows the driver to select 

high or low backlight illumination level).

[dFI] 

Initial defrost interval.

[ddr]

 Defrost duration.

*Each prompt or display screen will remain on the display for 
about 10 seconds. If no other key is pressed, the display will 
then return to the Standard Display of box temperature and 
setpoint.

Viewing and Clearing       

Alarm Codes

1. Press the ON key to 
turn the unit ON.
2. If the ALARM icon is 
present, one or more 
alarms have been 
detected.

To View Alarm Codes

1. Press the SELECT key to show the Alarm display screen. 
If more than one alarm code exists, each will be displayed for 
several seconds. The alarm code shown here is alarm code 66-
Low Engine Oil Level.

To Clear Alarm Codes

1. Correct the cause of the alarm code.
2. Press the SELECT key to display the alarm code.
3. Press the ENTER key to clear the alarm code.
If more than one alarm code is present, the ENTER key must 
be pressed to clear each alarm code individually.

Consult the operating manual for your Thermo King unit to view 
the complete list of possible alarm codes and their definitions. 
Consult unit operating, maintenance and parts manuals for 
additional information on unit operation and maintenance.

The µP-T Microprocessor is used on:

KD-II Smart Reefer Truck units

RD-II Smart Reefer Truck units

TD-II Smart Reefer Truck units

MD Smart Reefer Truck units

TS Smart Reefer Truck units

µP-T

Remote 

Control

Operating

Guide

Keypad/Display Descriptions

Selecting CYCLE-SENTRY or Continuous Mode

Starting the Engine

Initiating a Manual Defrost Cycle

Viewing Prompt and Display Screens

Viewing and Clearing Alarm Codes

TK 50772 - PC Rev 1, 04-08 © Thermo King Corporation

CAUTION: This is a quick reference guide. 
Always refer to the operating manual for detailed 
instructions.