Refrigeration Service Operations (Rev. 04/03)
83
gen before using. NEVER USE EQUIPMENT THAT MAY
BE CONTAMINATED WITH AUTOMOTIVE TYPE
POLYALKYLENE GLYCOL (PAG) OILS.
System Clean-up
Existing clean up devices such as suction line filters and
compressor oil filters may be used if they are thoroughly
cleaned and new filter elements are installed. All standard
compressor oils must be removed from clean-up devices to
prevent contamination of R-134a and R-404A systems.
Dangerous contamination will result if other refrigerants or
standard oils are introduced to R-134a or R-404A systems.
NOTE: For additional information on parts and supplies,
consult your local Thermo King dealer and Thermo King
Tool Catalog TK No. 5955.
Refrigerant Recovery
Present systems can be adapted to the recovery of R-134a
and R-404A but should be dedicated to the recovery of
these refrigerants. Consult the manufacturer of your recov-
ery equipment for details.
Summary of Contents for 088669
Page 4: ......
Page 8: ......
Page 12: ...Safety Precautions Rev 04 03 iv PUB126...
Page 13: ...Safety Precautions Rev 04 03 v aea105...
Page 14: ......
Page 28: ...Unit Description Rev 04 03 14 Rear View Curbside RD II SR Evaporator aea105...
Page 32: ...Unit Description Rev 04 03 18 Power Receptacle Box RD II SR 50 aea102...
Page 76: ...Refrigeration Maintenance Rev 04 03 62...
Page 77: ...Refrigeration Maintenance Rev 04 03 63...
Page 81: ...Refrigeration Maintenance Rev 04 03 67...
Page 103: ...89 Hilliard Clutch Maintenance Clutch Assembly...
Page 106: ...Hilliard Clutch Maintenance Rev 04 03 92 12 Install retaining ring Clutch Torque Values...
Page 125: ...111 Cool Cycle RD II SR with TherMax Heating...
Page 126: ...112 Condenser Cycle RD II SR with TherMax Heating...
Page 127: ...113 Heat and Defrost Cycle RD II SR with TherMax Heating...
Page 129: ...115...
Page 130: ...116...
Page 131: ...117...
Page 132: ...118...
Page 133: ...119...
Page 134: ...120...
Page 135: ...121...
Page 136: ...122...