Thermo Electron Savant SC250 Express Instruction Manual Download Page 3

3

1.0

INTRODUCTION

The Savant SC250 Express centrifugal vacuum concentrator, offers fast, 

reliable batch processing of samples.  It effectively removes a broad range of

aggressive and volatile solvents to concentrate or dry solutes, analytes and

residues while providing complete sample recovery. The heavy-duty Universal

Rotor is optimized for efficient large sample processing while accommodating

various sample handling formats.  

The combination of vacuum, applied to the sample chamber from an external

source, and centrifugal action promotes solvent evaporation without sample

loss due to foaming or bumping.  The evaporation process is accelerated with

the addition of chamber heat to counteract the extreme evaporative cooling of

the samples. The concentration process is completed with the addition of a

vapor condensation trap available separately for virtually 100% solvent 

recovery. This results in a thorough evaporation process in a safe environment

for both the sample and the user.

The compact, industrial strength SC250 Express features:

• 

heavy-duty Universal Rotor for high sample throughput and flexible sample

handling formats; carriers capable of holding interchangeable rotor blocks

for vials and tubes as well as multiple microplates 

ultimate chemical resistance to aggressive solvents with the following 

provisions:

-  rugged stainless steel magnetic drive lubricated with acid-resistant 

grease

- Teflon

®

and Teflon

®

coated materials used exclusively in the vapor path

-  dual valve manifold positioned to reduce solvent vapor exposure

-  dedicated bleed port added to assure unidirectional vapor flow and 

to purge bearings with fresh air

• 

faster evaporation rate with the following enhancements:

- enlarged vacuum port increases cross-section of vapor path

- built-in chamber radiant lamps positioned for optimal evaporation 

temperature of samples in the Universal Rotor

- heated glass cover adds radiant heat to samples and prevents 

condensation of DMSO on cover

microprocessor control of run and heat times offer fully unattended, 

automatic operation

built-in digital vacuum gauge and added sight glass allow continuous 

monitoring of process and system status as well as the visual inspection 

of the rotor movement

Summary of Contents for Savant SC250 Express

Page 1: ...Instruction Manual Savant SC250 Express SpeedVac Concentrator 121 3006 00 Rev B ...

Page 2: ...Connection to vapor trap and vacuum source 6 Section Operation Page 3 0 Operation 7 3 1 Sample Loading 7 3 2 Control Panel 8 9 3 3 Example of a manual run 9 10 3 4 Example of a auto run 10 11 3 5 Other Topics 11 3 6 Specifications 12 3 7 Rotor Rotor Blocks Carriers and Accessories 13 15 Section Warranty Liability Page 4 0 Warranty and Liability 15 Section Appendix Page Appendix 1 Maintenance and S...

Page 3: ...trial strength SC250 Express features heavy duty Universal Rotor for high sample throughput and flexible sample handling formats carriers capable of holding interchangeable rotor blocks for vials and tubes as well as multiple microplates ultimate chemical resistance to aggressive solvents with the following provisions rugged stainless steel magnetic drive lubricated with acid resistant grease Tefl...

Page 4: ...hipping damage against the carrier or its agent Save the shipping carton in the event a return is necessary Set up To assure safe operation and best results read this manual in its entirety before operating the SC250 Express concentrator 1 Savant SC250 Express SpeedVac Concentrator with attached SUMAX400 1 Teflon hose assembly 1 5 I D 1 Teflon tubing 1 2 I D x 4 long 1 Flask cap assembly 2 Clamp N...

Page 5: ...ures from sample solvent and to extend pump life a vapor trap that condenses and traps vapors must be placed in line between the SpeedVac concentrator and vacuum pump We offer integrated universal vacuum systems integrated vapor trap with vacuum pump or component vacuum system vapor trap plus vacuum pump See table 1 for recommended DDA components Call Thermo for the complete line of vacuum pumps a...

Page 6: ...e Universal Rotor UPR 4A onto the assembly SUMAX400 by visually aligning the pin on the drive shaft of the assembly with the groove on the bottom of the rotor 2 Rotate the rotor by hand to ensure alignment of the pin with the groove 3 Secure the rotor assembly by screwing the retaining knob into the drive shaft above the rotor 4 Tighten it firmly but not excessively When using a Thermo standard di...

Page 7: ...ilable from Thermo See Section 3 7 for available Rotor Blocks Always select a rotor or Rotor Block for which the sample tubes fit snugly Contact Thermo Technical Services for help on Rotor Block selection and custom Rotor Block needs 2 Load and balance all 4 carriers UPC 1 or UPC 2 with filled or empty Rotor Blocks When placing Rotor Blocks in the carriers make sure the side of the Rotor Block is ...

Page 8: ...TS UP DOWN Modifies selected parameter 5 VACUUM SET VACUUM CONTROLLER Selects either Level or Ramp in the VAC display Level Allows users to select a pre set vacuum level Once this level is obtained the microprocessor will regulate and maintain this vacuum level The vacuum level can be set from 20 torr to 100 mtorr Ramp The rate at which vacuum is achieved can be set for preventing bumping 5 adjust...

Page 9: ...est 1 lowest 7 Place the sample tubes in the rotor and ensure that the load is balanced Secure rotor with the supplied knob Close cover 8 Pre heat may be selected at this time to warm chamber to 45 C 9 Press the MANUAL RUN button The cover locks and rotor starts turning The decimal point blinks and the RUN TIME display counts up The temperature rises to the set temperature The HEAT TIME will count...

Page 10: ...AT TIME RUN TIME parameters RUN and HEAT TIME can be set from 0 01 to 9 59 hours HEAT TIME also has CCC for continuous use b To set a VACUUM LEVEL press VACUUM SET to illuminate LEVEL up down keys to set vacuum to desired level To select a vacuum ramp rate press Vacuum Set to illuminate RAMP and use the up down keys to set a ramp rate 5 highest 1 lowest 3 Place the sample tubes in rotor so load is...

Page 11: ...cover must be closed before beginning a run If you press Manual Run or Auto Run and the cover is open the display shows lid to remind you to close the cover A user cannot open the cover during a run due to vacuum in the concentrator chamber The cover is locked down at all times during a run and whenever power to the unit is interrupted The cover lock is an additional safety feature that reduces th...

Page 12: ... Teflon coated chemical resistant aluminum casting Includes four built in radiant lamps Cover Heated Glass chemical resistant Drive Stainless steel magnetic coupling drive with acid resistant Teflon bearings Vacuum Level Control 20 to 0 1 torr Vacuum Ramp Setting 1 to 5 5 maximum vacuum RUN and HEAT Timer 1 minute to 9 hours and 59 minutes continuous Temperature Set Range 45 to 80 C in 5 C increme...

Page 13: ...cal 28 x 115 mm 50 ml conical 28 x 115 mm 50 ml conical 28 x 115 mm 50 ml pear shaped flask 100 ml pear shaped flask 100 ml pear shaped flask 250 ml pear shaped flask 500 ml pear shaped flask 100 ml recovery flask 12 x 32 mm 1 dram vial 4 ml 12 x 40 mm vials 20 x 47 mm v vials 1 dram vials 15 x 45 mm 4 ml 20 x 60 mm v vials 18 x 52 mm mini scintillation vials 28 x 60 mm scintillation vials 28 x 60...

Page 14: ...Vial 50 28 x 60 mm scintillation vials UPR 4A Swing out horizontal rotor for holding carriers Carriers UPC 1 Single shelf carriers for Rotor Blocks set of 4 UPC 2 Double shelf carriers for deepwell plates set of 4 UPC 5 Five shelf carriers for microplates set of 4 Rotor Blocks Polypropylene Rotors Blocks Order Number Description RB12 25 52 12 2 dram vials 25 x 52 mm set of 2 RB12 27 60 12 5 dram v...

Page 15: ... radioactivity Under no circumstances shall Thermo be liable for damages due to the improper handling or use of its products Thermo assumes no liability express or implied for your use of this equipment It is the responsibility of the user to dispose of ALL materials in a manner in accordance with all federal state and local regulations 3 7 ROTORS ROTOR BLOCKS CARRIERS and ACCESSORIES cont d Alumi...

Page 16: ...ove the three screws that secure the SUMAX400 place screws in a safe place Remove the SUMAX400 by lifting it straight up using the rotor hold down knob Place the SUMAX400 in a plastic container Rinse the SUMAX400 thoroughly under running tap water to rid of all debris and residue Wipe the inside of the SpeedVac Concentrator with a damp paper towel Wipe the SUMAX400 dry with a paper towel Properly ...

Page 17: ......

Page 18: ...453 9222 Yokohama City Japan International Sales Office Locations Bioscience Technologies Thermo Electron Corporation 866 9 THERMO 866 984 3766 Molecular Biology info molbio thermo com Sample Preparation info sampleprep thermo com New Labs newlabs thermo com Services services biosciencetech thermo com Laboratory Pipetting and Consumables info pipettes thermo com Microplate Instrumentation info mic...

Reviews: