Installation Guide

Diplomat Inverter Mini

INQG0102

Thermia AB

32

Summary of Contents for MBH 200

Page 1: ...Installation Guide Diplomat Inverter Mini www thermia com...

Page 2: ...anty if these instructions are not adhered to during installation or service The English language is used for the original instructions Other languages are a translation of the original instructions D...

Page 3: ...brine 13 5 1 Brine connection alternatives 13 5 2 General information for brine connection 14 5 3 Alternative 1 left 15 5 4 Alternative 2 right 16 5 5 Alternative 3 top 17 6 Sensors and power supply 1...

Page 4: ...r that there are risks involved with ac tions to be taken The symbols are displayed to the left of the text and two different symbols are used to indicate the degree of danger Warning Risk of personal...

Page 5: ...contamination shall always be avoided In areas where there are exceptional water conditions with regards to hard water a softening filter may be necessary to use install The softening filter softens...

Page 6: ...1 6 Overview image 3a Hot water Heating system Power Brine Installation Guide Diplomat Inverter Mini INQG0102 Thermia AB 6...

Page 7: ...ne lines 1 and 2 can be connected on either the left or right hand sides or to the two knock out holes on the top 2 2 Diplomat Duo Inverter Mini 455 598 40 10 1450 10 1360 379 686 701 75 726 118 1 2 4...

Page 8: ...Recommended location 3 1 Transportation The heat pump must not be transported lying down Max 45 Maximum tilt 45 Diplomat Inverter Mini Diplomat Duo Inverter Mini 169kg 127kg Installation Guide Diplom...

Page 9: ...a bedroom The surrounding walls can amplify the sound from the heat pump 1930 mm 1550 mm 0 C OK 40 C 300 mm 300 mm 300 mm 10 mm 600 mm x4 1 2 3 Adjust the heat pump using the adjustable feet so that...

Page 10: ...condensation may drain from the condensation hole in the bottom of the heat pump preferably a concrete floor When placed on a wooden floor the floor should be reinforced to hold the weight of the heat...

Page 11: ...nge valve 80 Shut off valve 81 Filling valve 85 Venting valve 86 Safety valve Max 3 bar heat pump recommended 1 5 bar 87 Safety valve 9 bar hot water 91 Dirt strainer with shut off valve DN 25 113 Exp...

Page 12: ...alve 80 Shut off valve 81 Filling valve 85 Venting valve 86 Safety valve Max 3 bar heat pump recommended 1 5 bar 87 Safety valve 9 bar hot water 88 Valve pipe cold water 91 Dirt strainer with shut off...

Page 13: ...ion brine 5 1 Brine connection alternatives 1 Left knock out 2 Right knock out 3 Top knock out 1 2 3 Equipment set up for installing Filler cock Installation Guide Diplomat Inverter Mini Thermia AB IN...

Page 14: ...the 32 mm mark When the coupling is correctly placed the pipe will be visible at the curve of the coupling To disassemble 1 Push the plastic ring 2 Pull the pieces apart 1 2 Insulate the brine pipe a...

Page 15: ...es 3 Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out See picture below 4 Press the pipes on to the connections i...

Page 16: ...pes on to the connections in the heat pump See picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are brine in and brine out The...

Page 17: ...the pipes 3 Press the pipes on to the connections in the heat pump See picture below Install the insulated pipes from the inside of the heat pump and out Pay attention to which one of the pipes are b...

Page 18: ...llation can commence 6 2 Outdoor sensor 50 m 0 75 mm2 50 120 m 1 5 mm2 2 3x H H 220nMBB2 M404 C BM SLM 4n7MBK4 4n7MBK4 HIGH VOLTAGE HIGH VOLTAGE HIGH VOLTAGE 1 Improper placement 2 Proper place ment 6...

Page 19: ...culation pump L3 Inverter compressor Fuse size 400V 3N 50 Hz FUSE C CURVE 6kW 13A 13A 13A 16A 1 5 7kW 2kW 4kW Minimum recommended fuse size Maximum operating current of compressor 12 A at 230V nominal...

Page 20: ...rea but requires that the jumpers fitted in the terminals are re moved See connection picture To remove jumpers use a flat screw driver and remove the 2 red jumpers fitted on the terminal block before...

Page 21: ...lock before connecting the heat pump to the grid To get 2 4 6 kw inbuilt auxiliary heater power insert the attached white wire according to installation picture 1 2 3 kw without white wire inserted fo...

Page 22: ...part of 94 C Dirt strainer with shut off valve part of 94 D External container E External pump Filling and bleeding the water heater and heating system 1 Fill the water heater with cold water by openi...

Page 23: ...of the test close manual test Parameter Meaning Circulation pump 0 stop circulation pump 1 start circulation pump Brine pump 0 stop brine pump 1 start brine pump Circulation pump 0 compressor stopped...

Page 24: ...immersion heater 5 Make the desired changes 6 Confirm settings by pressing For steps kW and fuse sizes see electrical installation chapter 8 2 4 Underfloor heating or radiator system Important If the...

Page 25: ...open comfort adjustment Shows that the comfort adjustment window is active Shows that the heat curve window is inactive Press on the symbol to open heat curve settings Shows that the heat curve windo...

Page 26: ...wise the floor might get damaged 8 2 7 Adjusting the indoor temperature Comfort adjustment to change temperature On the start screen comfort adjustment of the indoor temperature may be done very easil...

Page 27: ...activated deactivated temporarily 8 3 Online The heat pump is factory prepared for monitoring and as an additional service being operated remotely via internet Thermia Online In order to use the Therm...

Page 28: ...ect changes made on the respective page Factory reset Resets values on the current menu page to default values Press Confirm change button to confirm or Discard change button to cancel Will only affec...

Page 29: ...nu is active inactive Alarm reset Reset all alarms Operating view icons Operating mode Off All functions off Components inside are still energized Restart Restarts the heat pumps control system Some c...

Page 30: ...the symbol to open heating settings view Heat curve view icons Radiator heating Indicates that radiator heating is active and underfloor heating is deactivated Sets default heat curve value to 40 C U...

Page 31: ...essor active Placed in the top bar of the display Hot tap water active Placed in the top bar of the display Pool heating active Placed in the top bar of the display Idle mode The heat pump has no acti...

Page 32: ...Installation Guide Diplomat Inverter Mini INQG0102 Thermia AB 32...

Page 33: ...Installation Guide Diplomat Inverter Mini Thermia AB INQG0102 33...

Page 34: ...Installation Guide Diplomat Inverter Mini INQG0102 Thermia AB 34...

Page 35: ...Installation Guide Diplomat Inverter Mini Thermia AB INQG0102 35...

Page 36: ...ed material Thermia reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes bein...