5
Settings and adjustments
The installer carries out the basic settings of the heat pump at installation. A number of settings and adjust-
ments that you can carry out yourself are described below.
N
Before changing the control computer’s set-
tings, first find out what these changes mean.
Make a note of the default setting.
5.1
Setting operating mode
COMPRESSOR
OPERAT.
AUX. HEATER
HOT WATER
AUTO
1. Open the menu OPERAT. in the INFORMATION menu. The asterisk
shows the current selection
2. Mark new mode using + or – button.
3. Press the right button once to confirm the choice.
4. Press the left button twice.
The following operating modes can be selected:
Operating
mode
Meaning
(OFF)
The installation is fully switched off. This mode is also used to acknowledge and reset
alarms.
AUTO
The heat pump automatically controls the compressor operation and auxiliary heater (if in-
stalled and activated in the system).
COMPRESSOR
The control system is controlled so that only the outdoor unit (compressor) is allowed to
operate. In this operating mode there won't be any auxiliary heating backup, if there's a
need for it and also peak heating charging (anti-legionella function) of the hot water will
not run because the auxiliary heater is not used.
AUX. HEATER
The control system only permits the auxiliary heater to be in operation (if installed and acti-
vated in the system).
HOT WATER
In this mode the heat pump only produces hot water. No heat is supplied for space heat-
ing.
Warning
If any operation mode other than AUTO or
AUX. HEATER is to be used during the winter
season, the water in the heating system must
be drained. Otherwise any alarms triggered
that will cause the outdoor unit to stop might
lead to freezing damage to the system.