4.2
Software selection/Set unit ID
Software selection:
Set unit ID:
At first boot and after reset of the unit in field:
Select Application and press right arrow
>
Application
System
Communication
Time/Date
OK
c
First page/Main window:
Select Menu (right)
Tank
Hot Water
TWC / WCS
0.0
0.0
ºC
ºC
Menu
>
OK
c
Select the correct application (up/down, then right)
>
EM_Cooling
EM_Shunt
EM_Pool
EM_TWC_WCS
OK
c
Select Installation and press right arrow
WCS
Manual test
Installation
OK
OK
>
OK
c
Activate the selected application (OK, then up/down, then OK). The unit will
then immediately restart and run the selected application
Title:
EM_TWC_WCS
Activate: No
OK
c
Installation:
Change Unit ID (OK, then up/down, then OK)
Installation
Unit ID: 0
OK
OK
OK
c
▪
TWC/WCS must be stated as ID: 1
Shunt 2/3 must be stated as ID: 2
Shunt 4/5 must be stated as ID: 3
Cooling/Cooling2 must be stated as ID: 4
Pool must be stated as ID: 5
Legacy control must be stated as ID: 8-15
Set as ID: 0 if it is not to be connected with the heat pump. Then press left twice to get to the main window.
RESET
An incorrect application selection can be changed by resetting the internal memory with the power on. On the right hand side of the
unit there is a small hole. Use the end of a paperclip or similar to press the reset button in the hole.
Installation Guide
Expansion module 1
Thermia Värmepumpar
VQILV502
21
Summary of Contents for Expansion module 1
Page 1: ...Installation Guide Expansion module 1 C OK ...
Page 24: ...Installation Guide Expansion module 1 VQILV502 Thermia Värmepumpar 24 ...
Page 25: ...Installation Guide Expansion module 1 Thermia Värmepumpar VQILV502 25 ...
Page 26: ...Installation Guide Expansion module 1 VQILV502 Thermia Värmepumpar 26 ...
Page 27: ...Installation Guide Expansion module 1 Thermia Värmepumpar VQILV502 27 ...