SuperCooler VI can cool within the temperature range 17°C - 30°C.
Switch on SuperCooler VI and press the function button until the icon for cooling is activated. The display shows the temperature that the unit
will cool down to. Use the arrow buttons to adjust the temperature. Cooling and the fan will both start immediately once the cooling function
has been activated.
When cooling, the speed of the fan can be regulated. The fan has three speeds, which is set by pressing the set speed button until the icon for
the desired speed is activated. If you select the automatic speed regulation, the speed on the fan is set in relation to how much the temperature
should be lowered in the room.
Once the room has reached the desired temperature, the compressor in SuperCooler VI will stop, thereby stopping the unit from cooling. The fan
will continue to run at the selected speed. If the fan is set to automatic speed regulation, the speed of the fan will drop to the lowest speed. The
compressor will start up again once the actual temperature exceeds the set temperature.
NOTE: If SuperCooler VI stops cooling and the display shows fault code E4, this means the water tanks need emptying. Follow the guidelines in
the section MAINTENANCE AND CLEANING on page 62.
HEATING
SuperCooler VI can heat within the temperature range 15°C - 25°C.
Switch on SuperCooler VI and press the function button until the icon for heating is activated. The display shows the temperature that the unit
will heat up to. Use the arrow buttons to adjust the temperature. When heating is activated, the heating function and the fan will start up im-
mediately.
NOTE: The fan will always run at the highest speed when heating and cannot be adjusted.
Once the room has reached the desired temperature, the condenser in SuperCooler VI will stop, thereby stopping the unit from heating and stop-
ping the fan. The condenser and the fan will start up again once the actual temperature goes under the set temperature.
NOTE: If a drain is not installed, the water tank in SuperCooler VI will fill up during heating. If the water tank is full, SuperCooler VI will stop heat-
ing and the display will show fault code E4. Follow the guidelines in the section MAINTENANCE AND CLEANING on page 62 for how to empty
the tank.
DEHUMIDIFYING
Switch on SuperCooler VI and press the function key until the letters DH are shown in the display and the icon for dehumidifying is activated.
Dehumidifying will start the moment the function is activated.
In order to achieve an optimal heating level it is recommended that
a drain hose is mounted to the drain for dehumidifying and heating.