21
OwNER’s mANuAl
Note:
If your pool heater does not operate for reasons other than those mentioned above, please contact
Consumer Assistance Center
(see p.4) to obtain the proper authorization for the warranty to apply.
Ask your electrician to verify your heat pump’s power supply by
checking over the l1 and l2 or l1, l2 and l3 connections in the
unit’s service box.
There is no display and the fan is not running,
but the compressor is running.
while your THERmEAu pool
heater is in the heating mode,
a large quantity of warm and
humid air passes over the
evaporator and causes con-
densation. It is normal to see
condensation dripping under
the heater.
To check if the water really is a
leak, you must stop the heater
and leave the pool pump running
for over 5 hours. If water is still
coming out of your heater after
this period, then call your dealer
for service.
There is water around the unit.
Heat loss is too much for the heater; cover your pool as often as
you can.
Evaporator restricted due to improper location (see section on
locating the unit).
Evaporator is dirty.
Restricted water flow.
Clean it.
Adjust water flow.
The heater is running but desired water
temperature cannot be reached.