21

OwNER’s mANuAl

Note:

 If your pool heater does not operate for reasons other than those mentioned above, please contact 

Consumer Assistance Center

 (see p.4) to obtain the proper authorization for the warranty to apply.

Ask your electrician to verify your heat pump’s power supply by 
checking over the l1 and l2 or l1, l2 and l3 connections in the 
unit’s service box.

There is no display and the fan is not running,  

but the compressor is running.

while your THERmEAu pool 
heater is in the heating mode, 
a large quantity of warm and 
humid air passes over the  
evaporator and causes con-
densation. It is normal to see 
condensation dripping under  
the heater.

To check if the water really is a 
leak, you must stop the heater 
and leave the pool pump running 
for over 5 hours. If water is still 
coming out of your heater after 
this period, then call your dealer 
for service.

There is water around the unit.

Heat loss is too much for the heater; cover your pool as often as 
you can.

Evaporator restricted due to improper location (see section on 
locating the unit).

Evaporator is dirty.  

Restricted water flow.

Clean it.

Adjust water flow. 

The heater is running but desired water  

temperature cannot be reached.

Summary of Contents for S100

Page 1: ...Owner s Manual PRINTED IN CANADA ...

Page 2: ...onnections 11 Electrical 12 Bonding 12 Bonding and plumbing step by step instructions 12 Electrical Connections 13 Electrical Diagrams 14 Service Analyzer Control 15 Electronic Temp Controls 16 Initial Startup 18 Meaning of Display Codes 19 Troubleshooting 20 Requesting Assistance or Service 22 Maintenance 22 Winterizing 22 Pool Heat Pump Warranty 23 Table of contents ...

Page 3: ...l components are of superior quality which presents you with an effective state of the art technology heat pump In general compared to other types of pool heaters such as gas or oil fired the THERMEAU pool heat pump has a lower heating capacity on a BTU hr basis Therefore it needs to operate for a longer time to accomplish the desired results Occasionally it may be necessary to run the heat pump f...

Page 4: ...rchase date of your device and your dealer s name address and telephone number Model Number_____________________________________________________ Serial Number______________________________________________________ Purchase Date_____________________________________________________ Dealer Name_______________________________________________________ Dealer Address_______________________________________...

Page 5: ... a task CAUTION The CAUTION sign denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in material damage particularly to the product up to the destruction of part or all of the product WARNING The WARNING sign denotes a hazard It calls attention to a procedure practice or the like which if not correctly perfo...

Page 6: ...ION Proper pool chemistry is vital to the life of your heater Pay particular attention to the total alkalinity and TDS It is highly recommended that you have your pool chemistry checked often by an independent pool store Water quality standards that must be strictly observed Description Normal Range Verification pH level 7 2 to 7 8 Once week Chlorine concentration 1 0 to 3 0 ppm Once 2 3 days Tota...

Page 7: ...mps 2 4 A 2 4 A 2 4 A 2 4 A 2 4 A Fan motor HP 1 3 1 3 1 3 1 3 1 3 Fan motor speed 825RPM 825RPM 825RPM 825RPM 825RPM Minimum circuit ampacity 30 A 30 A 40 A 40 A 50 A Maximum fuse 40 A 50 A 60 A 60 A 70 A Refrigerant R 410A R 410A R 410A R 410A R 410A Optimal water flow rate GPM 30 35 40 55 60 Max water flow rate GPM 100 100 100 100 100 Max water temperature 104F 104F 104F 104F 104F Dimensions in...

Page 8: ... PVC Titanium PVC Heating range F C Up to 104 F 40 C Up to 104 F 40 C Up to 104 F 40 C Voltage Hz Ph 208 240 60 1 208 240 60 3 575 600 60 3 Required breaker 60 60 30 Minimum circuit ampacity MCA 47 44 16 8 Plumbing connections 2 2 2 Water Flow GPM 60 to 125 60 to 125 60 to 125 Dimensions in inches H 48 W 33 D 39 H 48 W 33 D 39 H 48 W 33 D 39 Hot Gas Defrost Yes Yes Yes Weight lb 445 375 375 ...

Page 9: ...iciency The unit should be located as close as practical to the existing pool pump and filter to minimize water piping However do not forget to provide a 18 clear ance at the very least all around your heat pump Mount the unit on a sturdy base preferably a concrete slab or a set of blocks The size of the base should not be less than 40 x 40 100 cm x 100 cm All THERMEAU pool heat pump models featur...

Page 10: ...with PVC glue If rigid PVC is not available you can use soft or flexible piping with stainless steel clamps When the piping installation is complete operate the pool pump and check the system for leaks Then check the filter pressure gauge to verify that there isn t any indication of excessive pump head pressure You can also make the connections using high pressure flexible hose but make sure the h...

Page 11: ...s must be done in parallel An equal flow of water to each heat pump is important for optimum operation NOTE It may be necessary to adjust water pressure switch if a unit is installed below the water level Each heat pump allows a maximum flow rate of 125 gpm 473 L min and requires a minimum of 60 gpm 227 L min ...

Page 12: ...tomatic chlorine generator and any other metal or electrical equipment On some older pools this substructure bond wire may not exist In these cases a 6 to 8 foot solid copper rod must be driven into the ground near the equipment All electric and metal components must then be bonded to each other and then to the copper rod WARNING 1 A 1 3 lb check valve must be installed between the heater and any ...

Page 13: ...ng sequence that ll be the FAULT red light that come ON and the compressor won t start If this occurred you have to switch the L1 wire with L2 wire WARNING L3 L2 L2 L1 L1 Ground Ground ON FAULT Electrical Connections The installation of the THERMEAU pool heater should be performed by a cer tified electrician To connect the electricity you must unscrew the four screws of the front panel then slide ...

Page 14: ...14 Owner s manual ...

Page 15: ...s Heating mode Compressor running Heating mode To raise the desired temperature or to change parameters To lower the desired temperature or to change parameters Service Analyzer Control The control panel is factory set to display the temperature in Fahrenheit degrees Fig 5 ...

Page 16: ...ge the spa water temperature set point P S Changes between pool and spa settings LED s on front panel will indicate current mode selected C F Display temperature in Fahrenheit or Celsius Water Temperature Set Point Temperature set point range is OFF and 61 F to 95 F for POL mode For SPA mode set point range is OFF and 61 F to 104 F Pushing the UP arrow or DOWN arrow buttons will prompt the control...

Page 17: ...rature up until spa setting reads 104 3 Set unit to the POL mode 4 Connect remote system with 2 wires to the P S terminal on control board Figure 6 shows you where to connect the 2 wire remote systems to the temperature controller For 3 wire remotes 1 Bring up POL setting and use arrows to select desired pool temperature 2 Bring up SPA setting and use the arrows to select the desired spa tem perat...

Page 18: ...AUFFAGE indicator located on the right see Service Analyzer Control p 15 should be lit At initial startup it is normal for the unit to run 24 hours a day It is also normal to see water dripping from the holes at the base of the unit This is simple condensation Connection to AquaLink Compool Hayward AquaLogic or any other 2 wire remote system with their own thermostat Remove gray jumper from termin...

Page 19: ...ll stop your heater for protection Po Water temperature probe connected to 1 and 2 on electronic board may be disconnected If it is not the probe may be open or defective Pc Water temperature probe is short circuited or may be defective FLo FL3 Possible causes The FIL parameter must always be set to OFF The filter is in backwash position The filter pump is stopped The filter is dirty Shortage of w...

Page 20: ...ndicating FS The fan is running but the compressor is not Pool pump is not running Filter is dirty restricting the water flow Turn the pool pump on Backwash and clean filter The heater is displaying flo and it will not start Heat pump control set to OFF Desired water temperature is reached Main breaker is tripped Raise temperature set point above 60 F 15 C Unit will automatically restart when the ...

Page 21: ...g mode a large quantity of warm and humid air passes over the evaporator and causes con densation It is normal to see condensation dripping under the heater To check if the water really is a leak you must stop the heater and leave the pool pump running for over 5 hours If water is still coming out of your heater after this period then call your dealer for service There is water around the unit Hea...

Page 22: ... problem your heater s complete model and serial number and the purchase date see p 4 This information will help us respond properly to your request Keep a copy of the sales receipt showing the date of purchase Proof of purchase will assure you warranty service Maintenance Dirt can accumulate on the evaporator You can easily remove it by using a water spray without damaging the small aluminum fins...

Page 23: ...All Thermeau Industries inc pool heat pump must be installed according to manufacturer s specifications or the warranty will be null and void All warranty work must be performed by a Thermeau Industries inc authorized service center All warranty work must be approved prior to service center performing the work Any alteration or repair by any person agency or company not authorized by Thermeau Indu...

Page 24: ...ice center All warranty work must be approved prior to service center performing the work This warranty is applicable only if the heat pump has been installed operated and maintained expressly and com pletely in accordance with the owner s manual and the manufacturer s specifica tions Any alteration or repair by any person agency or company not authorized by Thermeau inc will void the warranty The...

Page 25: ...enter All warranty work must be approved prior to service center performing the work This warranty is applicable only if the heat pump has been installed operated and maintained expressly and com pletely in accordance with the owner s manual and the manufacturer s specifica tions Any alteration or repair by any person agency or company not authorized by Thermeau inc will void the warranty Thermeau...

Page 26: ......

Reviews: