Introduction

Welcome to a more comfortable, efficient way of heating your living spaces during cold weather!
ThermaWave Polar is the most complete and advanced space heating system on the market. It heats using a 
cutting-edge PTC (Positive Thermal Coefficient) element that heats the air efficiently without drying it out. It 
purifies your air with PCO technology that features a high power germicidal UVC bulb. This bulb, in conjunction 
with a catalyst, creates a purifying plasma that reduces mold, bacteria, and viruses (even on surfaces) so the 
months spent with doors and windows closed no longer means months spent in a stuffy indoor environment.
Polar is designed to provide years of trouble-free service when used and maintained according to this Owner’s 
Manual. The pages of this manual will guide you through proper operation, cleaning the filter, and replacing the 
PCO Cell as necessary.
Thank you for purchasing ThermaWave Polar by GreenTech Environmental.

Records

Purchase Date: __________________________________________________________________________
Model Number: __________________________________________________________________________
Serial Number: __________________________________________________________________________
Distributor Name: ________________________________________________________________________
Distributor Phone: ________________________________________________________________________

Features

PTC Infrared Heating Element
PCO Air Purification Technology
LCD Display
Unit Control Panel
Control Remote
Quiet Mode
Overheat Safety Shut Off
Tip-Over Safety Shut Off

 Benefits

Clean, Economical, and Safe Heating

Even Distribution of Heat from Floor to Ceiling

Does not Burn or Dry Out Air

Low Operating & Maintenance Cost

Efficient PCO Purification for Pure, Clean, Heated Air

Summary of Contents for Polar

Page 1: ...Polar Owner s Manual 3 4 5 6 7 8 10 11 Introduction Specifications Control Panel Remote Unit Diagrams Unit Setup Operation Maintaining the Unit Safety info Warnings Warranty Information ...

Page 2: ......

Page 3: ...ou through proper operation cleaning the filter and replacing the PCO Cell as necessary Thank you for purchasing ThermaWave Polar by GreenTech Environmental Records Purchase Date ___________________________________________________________________________ Model Number ___________________________________________________________________________ Serial Number __________________________________________...

Page 4: ...e Hot Air Outlet Specifications Voltage 120V 60Hz Power up to 1500 watts Heat Output 5200BTU Remote Battery CR2025 Temperature Control Range 60 90 Degrees Fahrenheit Heating Element Infrared Positive Thermal Coefficient PTC Element Air Filter Lifetime Washable Air Purifier Photo Catalytic Oxidation PCO Cell Display LCD Coverage Up to 1000 ft2 Dimensions 13 25 x 15 5 x 17 25 WxDxH Weight 26 6 lbs C...

Page 5: ...5 PURIFIER QUIET TIMER HEATER POWER COOLER WARMER PURIFIER QUIET TIMER Control Panel Remote Control Diagrams ...

Page 6: ...Copyright 2010 GreenTech Environmental All Rights Reserved 6 Unit Front Diagram Unit Rear Diagram ...

Page 7: ...er Mode on or off press the PURIFIER CONTROL button Set the desired temperature using the TEMPERATURE CONTROL buttons You may select a temperature from 60 to 90 degrees Fahrenheit Purifier Mode Toggle the Purifier Mode on or off at any time that the unit is turned on by pressing the PURIFIER CONTROL button Timer Function Set the TIMER FUNCTION by pressing the TIMER CONTROL button to activate it Pr...

Page 8: ...ification feature Check your HUMIDIFIER TRAY daily using the window in the HUMIDIFIER TANK CHAMBER DOOR Cleaning the Filter The filter should be cleaned every 30 days or more often if you find that the filter is collecting visible particulate 1 Unplug the POWER CORD from the outlet 2 Remove the FILTER ASSEMBLY SCREW using a screwdriver Place the screw aside where you will not misplace it 3 Allow t...

Page 9: ...GreenTech Environmental Authorized Distributor If your distributor is not available please visit www GreenTechEnv com to contact us regarding ordering a PCO Cell directly 1 Remove the FILTER ASSEMBLY by following steps 1 through 3 of Cleaning the Filter 2 Unplug the old PCO Cell by disengaging the electrical adapter in the lower right hand region of the rear of the unit 3 Unscrew the Thumbscrews a...

Page 10: ...milar attributes 6 Do not insert any foreign objects into the vent as this may cause an electric shock or damage the heater itself 7 Do not change the heater s wiring or design as it will void the warranty and could cause injury 8 Always unplug heater when not in use 9 Turn heater off before removing plug from outlet 10 Do not place cord under any kind of covering such as carpet rugs or similar ar...

Page 11: ...epaired or replaced part of unit shall be warranted to the original purchaser only for the length of the unexpired portion of the original warranty For the location of the nearest GreenTech Environmental Authorized Service Center or for other service information please visit us online at www GreenTechEnv com service Before any product is sent for service the customer should contact the GreenTech E...

Page 12: ...Version 1 ...

Reviews: