MicroTouch Control Installation Instructions
THERMASOL.COM
I
800.776.0711
7
6
Operation
Error Codes
The simplified error code reporting
system includes individual codes for
any applicable system fault.
+ –
The number of lit LEDs on the temperature
scale shows the type of error.
1 light
Room Over Temperature Error
2 lights
Reserved for Factory Use
6 lights
Low AC Voltage Error
7 lights
Low Water Error
8 lights
Reserved for Factory Use
9 lights
Reserved for Factory Use
10 lights
Communication Error
Taking a Steam Bath
On your ThermaSol MicroTouch Control, touch and
release the power icon twice to power on. To turn off
the steam unit touch and release the power icon once.
Power on is verified when the control face shows lit LEDs
and turns dark if power is off.
A steam session lasts 45 minutes and is loaded with
previously saved temperature set point.
Setting or Changing the Temperature Set Point
Set the temperature of your ThermaSol steam shower
by using the lit plus
+
or minus
–
symbols, which are
located immediately to the left and to the right of the
power icon. An arc array of lit squares will appear
from left to right.
Increase the temperature by touching
+
symbol
until desired temperature is displayed by the
blue LED lights running clockwise to indicate an
increase in temperature.
Reduce the temperature by touching
–
symbol
and the array of LEDs will begin to turn off.
Power Flush
ThermaSol’s internal diagnostic system will alert you
when a Power Flush cleaning is needed (Maintenance
mode) by LEDs running counterclockwise.
Start a Power Flush cleaning cycle
To start a power flush manually, press and hold the
+
and
–
buttons for 5 seconds while the MicroTouch is
in the on state. To indicate that the unit is in power flush
mode, the array LEDs will flash in a clockwise direction.
A
B
C
Solid Aluminum Body
Bright LED Display
Capacitive Touch Area
Built-in Infrared
Temperature Sensing (ITS)
Temperature
Adju/-
Power On/Off
A
B
C
Maintenance mode indicated
by counter clockwise LEDs
LEDs will blink to show an error
Read warnings on page 3. For illustrative purposes only. Consult with qualified professional for steam room construction details.
PN: 81193_NC 4/16