AF Series Generator

OVER 60 YEARS OF STEAM SHOWER INNOVATION

Installation Operation Manual

thermasol.com/solutions

SSA-ACR, SSA-84, SSA-140, SSA-240, SSA-395, SSA-575

Summary of Contents for AF Series

Page 1: ...AF Series Generator OVER 60 YEARS OF STEAM SHOWER INNOVATION Installation Operation Manual thermasol com solutions SSA ACR SSA 84 SSA 140 SSA 240 SSA 395 SSA 575 ...

Page 2: ...SHOULD NEVER BE LOCATED OUTSIDE THE HOME All products must be installed in accordance with installation instructions provided Failure to do so may invalidate warranty at manufacturer s discretion 2018 ThermaSol 2 THERMASOL COM I 800 776 0711 Make sure the walls ceiling and floor materials are suitable for use with steam All penetrations through the vapor barrier of the shower must be completely se...

Page 3: ...A ACR generator for acrylic modules Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details The size of the shower will determine the size of the generator The size of the generator will determine electrical requirements q All the electrical wiring must be done per National Local Electrical Codes q Run 240V Power source to the ...

Page 4: ... up to 50 feet away from steam shower and must be in a dry non combustible well ventilated space with 6 clearance around generator When constructing the ceiling add slope of 1 foot The control cable provided with the generator is 50 feet in length Item 03 6152 050 When locating the control unit place it as far as possible away from the steam head and as close as is practical to where the user will...

Page 5: ...4 drain connection on pan to an approved drain Drain Pan must be installed on all generator installations All plumbing shall be performed by a qualified licensed plumber and in accordance with applicable national and local codes Connect a tee to the existing cold water line Install copper pipe from the tee to create inlet line for unit Install a brass shut off valve on the water inlet line in an a...

Page 6: ...e runs to the back of the control in the the shower location or to the SWM 2 or PDM if present DO NOT pinch nail staple wedge or bind the data cable DO NOT wrap the data cable around steam line or route it in a manner so that the hot steam line could melt the cable Any damage to the control cable will result in the control not working properly Carefully connect the data cable to the generator and ...

Page 7: ...easy installation not included Use 1 2 brass pipe or copper tubing from unit to steamhead rough in fitting as permitted by codes The steam line can run up and then down once or horizontal but never run down and then up If it does a steam trap will be produced at the low point blocking the flow of steam Insulate the steam outlet piping if the piping run exceeds 10 feet or is exposed to cold areas U...

Page 8: ...all or wall above bathtub rim for the steam outlet rough in fitting and install to be flush with the finished wall this housing must be sealed to the wall to not allow vapor or water behind it plumbing must be done from backside of finshed space For new framing Mount and install rough in fitting to be flush with finished wall Connect a 1 2 NPT brass pipe or copper tubing to the steam outlet union ...

Page 9: ...ck and any other options if applicable Registration information on page 12 9 Final Pre Check Before Operation 9 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details THERMASOL COM I 800 776 0711 Once the shower wall is complete and the housing is sealed to the wall remove the protective cap and insert the steamhead into housi...

Page 10: ...eries Generator Installation Instructions Notes 10 Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details THERMASOL COM I 800 776 0711 ...

Page 11: ...F Series Generator Installation Instructions Notes Read warnings on page 2 For illustrative purposes only Consult with qualified professional for steam room construction details THERMASOL COM I 800 776 0711 ...

Page 12: ...echnical Support Department In addition we ll keep you informed about your product and time to time we ll update you about new products and other company announcements Thank you from all of us at ThermaSol and we wish you many relaxing and steamy days ahead We will not sell rent or share your personal information You may also fill out the form on the back side of this page and mail it to 1958 Stea...

Page 13: ...r these warranties must be submitted and resolved by arbitration in Texas EXCLUSIONS These warranties will be terminated by ThermaSol for the following reasons 1 Improper installation such as installation that fails to observe National Local Plumbing and or Electrical codes 2 Use of a residential unit in a non residential or commercial application including a hotel 3 Service to equipment by unauth...

Page 14: ...1958 STEAM WAY ROUND ROCK TX 78665 PHONE 800 776 0711 FAX 800 556 5257 WWW THERMASOL COM 81186 Rev A 3 19 ...