Thermal AXAI-06M Installation Manual Download Page 8

 

  

  

Do not install the unit in a place where there is a chance of flammable gas leaks. 

If 

there is a gas leak and gas accumulates in the area surrounding the unit, it could cause an 
explosion.  

  

Perform the drainage/piping work according to the installation instruction. 

 

If there is a defect in the drainage/piping work, water could leak from the unit and household 

goods could get wet and be damaged.  

  

Do not clean the unit when the power is ‘on’. 

 

Always shut ‘off’ the power when cleaning or servicing the unit. If not, it could cause an injury 

due to the high speed running fan or an electrical shock.  

 

 

Do not continue to run the unit when there is something wrong or there is a strange 

smell.  

 

The power supply needs to be shut ‘off’ to stop the unit; otherwise this may cause an 

electrical shock or fire.  

 

 

Be cautious when unpacking and installing the product.  

 

Sharp edges could cause injury. Especially watch the edges and the fins on the heat 

exchanger of the product.  

 

 

Always check for gas (refrigerant) leakage after installation or repair of product.  

Low refrigerant levels may cause failure of the product.  

 

 

The installation of the unit must be level and secure.  

 

To avoid vibration and or water leakage  
  

Do not put your fingers or others into the fan, or evaporator.  

The 

fan runs at high speed, this could cause serious injury.  
  
In  order  to avoid a  hazard due to  inadvertent resetting  of the  thermal cut-out, this 

appliance must not be supplied through an external switching device, such as a timer, or 
connected to a circuit that is regularly switched on and off by the utility.  

This appliance has not been designed for use by persons (including children) with reduced 

physical, sensorial or mental faculties or by persons without any experience or knowledge of 
heating systems, unless they act under the safety and supervision of a responsible person 
or have received prior training concerning the use of the appliance. Children should be 
supervised to ensure that they do not play with the appliance.  

  
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent 

or a similarly qualified person in order to avoid a hazard. The means for disconnection must 
be incorporated in the fixed wiring and have an air gap contact separation of at least 3mm in 
each active(phase)conductors.  

  
  
  
  
  

Summary of Contents for AXAI-06M

Page 1: ...Inverter Air Source Heat Pump Monobloc system Product Data Installation Manual AXAI 06M AXAI 09M AXAI 12M AXAI 15M TABLE OF CONTENT ...

Page 2: ...it External Internal AXAI 06M AXAI 09M 7 The unit External Internal AXAI 12M AXAI 15M 8 Wiring Diagram 9 Electrical Wiring Diagram for the 6 9KW 9 Electrical Wiring Diagram for the 12 15KW 10 Field Wiring 11 WATER PIPE WORK 12 Checking the water circuit 12 Charging water 12 Water Flow Rates 12 INSTALLATION OF THE MAIN UNIT 13 Precautions for selecting the location 13 Installation space 13 Mounting...

Page 3: ...ATION INTRODUCTION This manual This manual includes the necessary information about the unit Please read this manual carefully before you install the product Domestic hot water tank option An optional domestic hot water tank with integrated electrical booster heater can be connected to the unit The domestic hot water tank is available in different sizes Items inside product box Before starting ins...

Page 4: ...AXAI 12M AXAI15M 1 ...

Page 5: ...4 The manual 1 ...

Page 6: ...5 OFN Regulator 26 PPE ie gloves glasses and steal toe protectors SAFETY INSTRUCTIONS To prevent injury to the user other people or property damage the following instructions must be followed Incorrect operation due to ignoring these instructions may cause harm or damage Install the unit only when it complies with local regulations by laws and standards Check the main voltage and frequency This un...

Page 7: ... sure to use a dedicated section If the capacity of the power circuit is insufficient or there is an incomplete electrical circuit it could result in a fire or an electric shock The unit must always have an earthed connection If the power supply is not earthed you may not connect the unit Do not attempt move repair the unit yourself if you are not a LCP installer Improper movement or repair on the...

Page 8: ...frigerant levels may cause failure of the product The installation of the unit must be level and secure To avoid vibration and or water leakage Do not put your fingers or others into the fan or evaporator The fan runs at high speed this could cause serious injury In order to avoid a hazard due to inadvertent resetting of the thermal cut out this appliance must not be supplied through an external s...

Page 9: ...4mm2 shielded heat resistance cables 12KW 15kw used 3 core 6mm2 shielded heat resistance cables An isolator is required as part of the field wiring Power cable to the indoor unit 3 core 2 5mm2 shielded heat resistance cable An isolator is required as part of the field wiring Low voltage inter connecting cable 75mm shielded twisted pair NB all controls cable must be installed 300mm away from mains ...

Page 10: ...9 Cycle diagram AXAI 06M AXAI 09M AXAI 12M AXAI 15M OVERVIEW OF THE UNIT External AXAI 06M AXAI 09M ...

Page 11: ...10 Internal AXAI 06M AXAI 09M ...

Page 12: ...11 External AXAI 12M AXAI 15M Internal AXAI 12M AXAI 15M ...

Page 13: ...12 Wiring Diagram Electrical Wiring Diagram for the 6 9KW ...

Page 14: ...iagram for the 12 15KW NB cable entry either top or bottom of the unit The unit Separated Power supply Model Separated Power supply Rated Current AXAI 06M 2200W 9 6A AXAI 09M 2500W 11 9A AXAI 12M 4200W 14A AXAI 15M 4400W 19A ...

Page 15: ... a dedicated power supply Never use a power supply shared by another appliance Be sure to establish an earth Do not earth the unit to a utility pipe surge absorber or telephone earth Incomplete earth may cause electrical shock Be sure to install an earth leakage protector Failure to do so may cause electrical shock Wiring overview The table below gives a wiring overview of required field wiring AX...

Page 16: ...ake sure the automatic air purge valve is open at least 2 turns 3 Fill with water until the water manometer indicates a pressure of approximately 2 0 bar Remove air in the circuit as much as possible using the air purge valves Air present in the water circuit might cause malfunctioning of the optional backup heater 4 Backup heater Check that the backup heater vessel is filled with water by opening...

Page 17: ...ar a bedroom and the like so that the operation noise will cause no trouble 4 There must be sufficient space for carrying the unit into and out of the site 5 There must be sufficient space for air passage and no obstructions around the air inlet and the air outlet 6 The site must be free from the possibility of flammable gas leakage in a nearby place 7 Install units power cords and inter unit cabl...

Page 18: ...ation drawing It is best to screw in the foundation bolts until their length remains 20mm above the foundation surface NB Wall brackets are not supplied with the unit unless specified an installation guide is supplied within the wall brackets packaging Check before running Check before initial startup Turn off the power before connecting After installation before accessing circuit breaker please c...

Page 19: ...ueezed 7 The refrigerant leak Check whether the machine refrigerant leakage if there is a leak contact your local dealer 8 Power voltage Check the power supply voltage on the screen the supply voltage must be consistent with the nameplate on the machine 9 Air vent valve Make sure the air vent valve is open at least 2 turns 10 The atmospheric valve After checking the atmospheric valve is opened whe...

Page 20: ...input KW 1 34 2 2 2 8 3 52 COP W W 3 74 3 63 3 57 3 55 Power supply V Ph Hz 220 240 1 50 Max power input KW 2 2 3 2 4 4 8 Max current A 9 6 14 18 21 Max leaving water temperature without using backup heater 58 Working temperature range 20 43 Refrigerant circuit Refrigerant Type R410A Compressor Brand Q ty Type TOSHIBA 1 Inverter Rotary TOSHIBA 1 Inverter Twin Rotary Heat exchanger Type High effici...

Page 21: ... weight Kg 98 118 135 160 Noise level dB A 50 53 60 62 NOTES Capacities and power inputs based on the following conditions Heating Water Inlet Outlet temperature 30 35 Outdoor air dry bulb wet bulb temperature 7 6 Cooling Water Inlet Outlet temperature 23 18 Outdoor air dry bulb temperature 35 Domestic Hot Water Water temperature in the tank 40 Outdoor air dry bulb wet bulb temperature 7 6 The rel...

Reviews: