![Thermal AXAI-06M Installation Manual Download Page 17](http://html.mh-extra.com/html/thermal/axai-06m/axai-06m_installation-manual_1103121017.webp)
16
12kw
2.06m³ /h
15kw
2.6m³ /h
INSTALLATION OF THE MAIN UNIT Installation guidelines Precautions for selecting the
location
WARNING
MAKE SURE TO PROVIDE FOR ADEQUATE MEASURES IN ORDER TO PREVENT
THAT THE OUTDOOR UNIT WILL BE USED AS A SHELTER BY SMALL ANIMALS.
SMALL ANIMALS MAKING CONTACT WITH ELECTRICAL PARTS CAN CAUSE
POSSIBLE MALFUNCTIONS, SMOKE OR FIRE. PLEASE KEEP THE AREA AROUND
THE UNIT CLEAN.
1. Choose a place solid enough to bear the weight and vibration of the unit, where the
operation noise will not be amplified.
2. Choose a location where the hot air discharged from the unit or the operation noise will
not cause a nuisance to the neighbors of the user.
3. Avoid places near a bedroom and the like, so that the operation noise will cause no
trouble.
4. There must be sufficient space for carrying the unit into and out of the site.
5. There must be sufficient space for air passage and no obstructions around the air inlet
and the air outlet.
6. The site must be free from the possibility of flammable gas leakage in a nearby place.
7. Install units, power cords and inter-unit cables at least 3m away from television and radio
sets. This is to prevent interference to images and sounds.
8. Depending on radio wave conditions, electromagnetic interference can still occur even if
installed more that 3m away.
9. In coastal areas or other places with salty atmosphere of sulfate gas, corrosion may
shorten the life of the outdoor unit.
10. The water will flows out of the unit when in defrost, do not place anything under the unit
which must be kept dry.
Installation space