background image

 
 
4. 

 Use a 3/16” drill bit to drill 3 starter holes 3/8” deep 
 through the 3 holes in the cabinet and into the windowsill. 

 

 

5. 

Attach cabinet to windowsill with 3 - #10 x 1/2” pan-head 
Phillips screws. 

 

950-0077-revD                                                                        Page 8 of 16                                                                       9 May 2007 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

6. 

Check that air conditioner cabinet is tilted to the outside so  
that water will run to the outside. 

 
__________________________________________________ 

Attach Side Curtains to Window Frame 

__________________________________________________ 
 
1. 

Pull Left-hand curtain out until it fits into window channel. 

        Use a 3/32” drill bit to drill a starter hole through the hole in     
        the curtain housing and into the lower windows sash. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

2. 

Insert one of the #10 x ¾” round-head screws through hole 
and into lower window sash.  

3. 

Insert one of the #10 x ¾” round-head screws through 
threaded hole in top of curtain. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

4. 

Repeat for right-hand curtain. 

 
_______________________________________________________ 

Complete Window Installation 

_______________________________________________________ 
 

1. 

Insert foam seal behind the top of the lower window sash 
and against the glass of the upper window. 

2. 

Place window-lock bracket on top of lower window and 
against upper window sash. 

3. 

Use a 3/32” drill bit to drill a starter hole through the hole in 
the bracket and into the window sash. 

4. 

Attach window-lock bracket to window sash with #10 x ¾” 
round-head screw to secure window in place. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for 420-0011

Page 1: ...WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950 0077 revD Page 1 of 16 9 May 2007 CATALOG NO PRODUCT CODE WAC10115R 420 0011 WAC12230R 420 0013 CATALOG NO PRODUCT CODE WAH8115M 420 0023...

Page 2: ...We have provided many important safety messages in this manual and on your appliance Always read and follow all safety instructions 950 0077 revD Page 2 of 16 9 May 2007 This is the safety alert symbo...

Page 3: ...r will be installed Proper Here Installation is your responsibility Make sure you have everything necessary for correct installation Tools Needed The location should provide Flat Blade and Phillips sc...

Page 4: ...rame Control panel area B Width 22 5 8 57 5 cm plus twice the thickness Of the wood used to build the frame Specific Electrical requirements are listed in the chart below C Wood thickness D Dimension...

Page 5: ...supply cord is ready for operation NOTES The reset button must be pushed for proper operation The power supply cord must be replaced if it fails to trip when the test button is pressed of fails to re...

Page 6: ...out of the cabinet Place the air conditioner on cardboard NOTE Do not lift push pull or remove any expanded polystyrene foam from inside the air conditioner It is NOT packing material Window Installat...

Page 7: ...ain housing into guides as far as it will go 6 Repeat above steps for left hand curtain Attach Foam Adhesive Seal _______________________________________________________ Attach foam adhesive seal alon...

Page 8: ...e hole in the curtain housing and into the lower windows sash 2 Insert one of the 10 x round head screws through hole and into lower window sash 3 Insert one of the 10 x round head screws through thre...

Page 9: ...round wire to cabinet base with ground screw Position ground wire pointing straight up Put excess ground wire between coil and air conditioner cabinet 4 Insert front tabs of front panel into top of ca...

Page 10: ...__ MODE ______________________________________________________ 1 Press MODE until you see the indicator light turn on for the mode you desire 2 Choose Cool Fan Only or Power Saver Cool Cools room You...

Page 11: ...settings 1 Turn off air conditioner 2 Press TIMER Timer indicator light will flash Display will show remaining hours before air conditioner will turn on 3 Press the plus or minus button to change del...

Page 12: ...it 10 seconds Indicator light on air conditioner control panel will remain on To set Timer to turn on air conditioner keeping previous settings 1 Turn off air conditioner 2 Press TIMER Indicator light...

Page 13: ...movement from the fan Clicks from the thermostat cycle Vibrations or noise due to poor wall or window construction A high pitched hum or pulsating noise caused by the modern high efficiency compressor...

Page 14: ...______________________________________________ Air conditioner seems to run too much _______________________________________________________ The current air conditioner replaced an older model The use...

Page 15: ...17 3 52 AIRFLOW CFM MAX 310 306 310 VOLTAGE FREQ 115 VAC 60 HZ 115 VAC 60 HZ 208 230 VAC 60 HZ COOLING AMPS 9 74 11 8 2 HEATING AMPS 12 6 NA NA COOLING WATTS 972 1250 1595 HEATING WATTS 1380 NA NA PL...

Page 16: ...rovides free replacement of defective parts only Labor and replacement parts as a result of normal wear and tear are not covered under this warranty Additional claims are excluded unless required by n...

Reviews: