Warranty Information 
 

Thermal Edge products are warranted to be free of defects in workmanship, materials and components. 
The warranty period applies from date of shipment for one year.  

The above warranty applies when the equipment is operated under the following conditions:  

 

Ambient temperature not in excess of performance rating in norma l atmosphere or as stated on 
product nameplate 

 

Voltage variation no greater than ± 10% from nameplate rating 

 

Maximum cooling load no higher than air conditioner nameplate rating  

 

Waiting five minutes before restarting air conditioner after intentional or ac cidental shutoff 

 

Compliance to all other installation, maintenance and oper ating instructions, as supplied 

Thermal Edge cannot assume responsibility for misapplication of its products or the erroneous selection of 
an inappropriate product by a non-authorized Thermal Edge representative. Our applications engineers 
will gladly assist in the selection of the proper product provided all required details of the application are 
furnished. 

Thermal Edge assumes no liability beyond the repair or replacement of its o wn product. This Warranty 
does not cover: 

 

Labor or reimbursement of labor for evaluation, removal, installation, repair, or cost of any 
warranted part, except at the Thermal Edge factory in Dallas, Texas 

 

Use of equipment for other than its designed purpose or operating conditions 

 

Operation in harsh, oily, corrosive or other abnormal environmental conditions, without the proper 
filtration, sealing, protective coatings and/or weather protection  

 

Damage to hermetic system resulting from continuous operation wit h dirty or clogged air filters or 
improper or negligent maintenance 

 

Use of refrigerant other than designated 

 

Customer modification or abuse 

 

Shipping damage or other accident 

 

Repair or service by unauthorized personnel. 

Cracked or broken hermetic tubing or brazed joints caused by shipping damage or mishandling are  not 
covered under the Warranty.  Claims for shipping damage are the responsibility of the Consignee. Timely 
claims must be filed with the freight carrier. 

The purchaser assumes the responsibility of grounding the unit and installing it in accordance with local 
electrical and safety codes, as well as the 2008 National Electric Code (NEC) and OSHA. 

THIS WARRANTY CONSTITUTES THE ENTIRE WARRANTY WITH RESPECT TO THE PRODUCT AND 
IS IN LIEU OF ALL OTHERS, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY OF 
MERCHANTABILITY AND WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE AND IN NO 
EVENT IS THERMAL EDGE RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY NATURE 
WHATSOEVER. 

Summary of Contents for CS011 Series

Page 1: ...User Technical Manual CS011 D48 Series Rev 1 2...

Page 2: ...nt of Confidentiality The Manual and other materials contain proprietary information comprising Thermal Edge Inc s trade secrets Please maintain the confidentiality of all proprietary information duri...

Page 3: ...4 Moving the Air Conditioner 5 Unit Label 5 Operation 6 Preliminary Testing 6 Mounting the Air Conditioner 7 Unit Specifications 8 Options 10 System Faults 13 Digital Temperature Controller Programmi...

Page 4: ...ecting the Equipment Thermal Edge air conditioning equipment is designed manufactured and packed to prevent damage from normal handling shock and vibration during shipment It is necessary to inspect y...

Page 5: ...s without damaging the compressor See Mounting the Air Conditioner for more information If air conditioner is to be shipped or transported at any time pack in original packaging and strap to pallet to...

Page 6: ...Condensate Removal System that changes the excess humidity liquid into a vapor which is then vented to the atmosphere In the event of excess water vapor when the enclosure door has been left open the...

Page 7: ...less than a 3 clearance for the supply air to one of the coils without affecting performance Mount the air conditioner high on the enclosure in order to cool the hot air at the top of the enclosure P...

Page 8: ...ovides electrical and refrigeration specifications for the CS011 D48 Series Air Conditioners CS011 Series Nominal Capacity Rating 1 000 BTUH Standard Maximum Ambient 125 F Unit Weight 30 lbs 120VAC Mo...

Page 9: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 1 2 9 P a g e THIS PAGE IS INTENTIONALLY LEFT BL...

Page 10: ...oint Default Settings 105 F Dry Contact High Temperature Alarm Set Point 2 F Recovery Differential 3min Temperature Alarm Delay At the default settings the Dry Contact initial conditions are normally...

Page 11: ...the Digital Temperature Controller Programming section for details on all default settings Open Door Kill Switch This option provides you with an adjustable and mountable safety switch for your elect...

Page 12: ...drogen sulfide chlorine etc Condenser and evaporator coils are available with electrostatically applied epoxy coating to prevent corrosion Three options are available to protect the air conditioner fr...

Page 13: ...time delay A thermal overload protects the compressor against faults In the event that the snowflake status LED is not flashing on the display and the compressor is not running an internal fault may...

Page 14: ...ey to display its value 4 Use the UP or DOWN arrow key to change its value 5 Press SET to store the new value and move to the following parameter To exit Press SET UP arrow keys or wait 15 seconds wit...

Page 15: ...min start up delay No Output 2 HA2 Condenser High Temperature Alarm P2 145 F for 3 minutes Compressor Off 2 LA2 Condenser Low Temperature Alarm P2 50 F for 3 minutes No Output 2 CA Evaporator Coil Al...

Page 16: ...e high efficiency long life sealed ball bearing fans engineered for optimum performance that require no maintenance Keep fan blades clean for optimal performance Fans are removable and attached by plu...

Page 17: ...e Qty 2 Thermal Expansion Value TXV 32025 1 Compressor 31659 1 Gasket Installation Kit 71410 CS01 Evaporator Fan 41002 2 1 Condenser Fan 41002 2 1 Note Qty 2 Safety Information Unit is carefully desig...

Page 18: ...on position ON OFF Toggle Switch then Retry Verify input power meets voltage requirements as shown in the UL label YES If problem is still present contact technical support Unit Overheats Insufficient...

Page 19: ...sor Use meter 3 Check for faulty evaporator fan 3 Measure Temperature at Evaporator Verify Heat Load Requirements Is unit capacity adequate for internal head load Possible low refrigerant Is compresso...

Page 20: ...ind controller CA YES NO Check Low Pressure Switch Connections and Verify Pressure switch is closed Use meter 3 P1 or P2 NO YES Check probe connections potential faulty probe LA LA2 HA HA2 YES Refer t...

Page 21: ...g e Physical Dimensions Water overflow excessive Check drain is it plugged YES NO Clean condensate pan and drain add 1 tbsp bleach to upper pan monthly to kill mold Is Air Conditioner sealed against...

Page 22: ...Hurd Drive Irving Texas 75038 972 580 0200 888 580 0202 Fax 972 580 0277 URL www thermal edge com Email support thermal edge com SP ENG 211 D48 02 Rev 1 2 22 P a g e THIS PAGE IS INTENTIONALLY LEFT B...

Page 23: ...al edge com SP ENG 211 D48 02 Rev 1 2 23 P a g e Electrical Schematics System Schematic Digital Controller Schematic Note Schematics apply to all voltages optional accessories wiring not provided in t...

Page 24: ...wn product This Warranty does not cover Labor or reimbursement of labor for evaluation removal installation repair or cost of any warranted part except at the Thermal Edge factory in Dallas Texas Use...

Page 25: ...d address Shipping method Pack unit in a suitable packing for shipment preferably the original packaging if available If suitable packing is not available arrange for packaging to be shipped to you Ai...

Page 26: ...om the left connect the wires by inserting them into the lower receptacles located on the front of connector in the following order NOTE If using stranded wires it may be difficult to insert into the...

Reviews: