APPENDIX
J3-1
36 VAC to ON/OFF Switch
J3-2
36 VAC from ON/OFF Switch to Logic/Gate PC Board
J3-3
36 VAC to ON/OFF Switch
J3-4
36 VAC from ON/OFF Switch to Logic/Gate PC Board
J3-5
Logic Low - From RUN/SET/LATCH Switch on Front Panel (RUN)
J3-6
PCB Common
J3-7
+10 vdc to Front Panel Current Control Pot J14-1
J3-8
From Front Panel Current Control Pot Wiper J14-2
J3-9
To Current Control Pot J14-3 (Return)
J3-10
Unreg18 VDC to Front Panel (J14-4)
J3-11
Logic Low for AC Indicator on Front Panel (J14-5)
J3-12
Logic Low for GAS Indicator on Front Panel (J14-6)
J3-13
Logic Low for TEMP Indicator on Front Panel (J14-7)
J3-14
Logic Low for DC Indicator on Front Panel (J14-8)
J3-15
Not Used
J3-16
Logic Low - From RUN/SET/LATCH Switch on Front Panel (LATCH)
J5-1
36 VAC to CD PC Board (J11-1)
J5-2
36VAC Centertap to CD PC Board (J11-2)
J5-3
36 VAC to CD PC Board (J11-3)
J5-4
Logic Low CD Enable Signal to CD PC Board (J11-4)
J5-5
CD Enable Return to CD PC Board (J11-5)
J5-6
Unreg18 vdc to PCR Relay
J5-7
Logic Low PCR Signal to PCR Relay
J5-8
Logic Low Torch Switch Input from Pilot/Output PCB (J13-1)
J5-9
Torch Switch Return to Pilot/Output PC Board (J13-2)
J5-10
Logic Low - OK-To-Move Signal to Pilot/Output PC Board (J13-3)
J5-11
Unreg18 VDC for OK-To-Move (CSR) Relay on Pilot/Output PC Board (J13-4)
J5-12
PS + from Pilot/Outut PCB to sense Positive Output Voltage
J5-13
Not Used
J5-14
From Pilot/Output PC Board to Sense Drag Cutting (Tip)
J5-15
Not Used
J5-16
PS - From Pilot/Output PC Board to Sense negative DC Output Voltage
J10-1
Logic Low - MC1 Contactor to Input PC Board (J16-1)
J10-2
Unreg18 VDC to Input PC Board for K11 Relay on Input PCB
J17-1
Logic Low - CSR Signal from Current Sensor
J17-2
Return for CSR Signal
J17-3
+12 VDC to Current Sensor
TP1
Logic Ground
TP2
Unreg18 VDC
TP3
Unreg18 VDC
TP4
Not Used
TP5
+12 VDC
TP6
+12 VDC
TP7
Drag Circuit Disable (jumper to TP1)
TP8
Negative Voltage Sensing - jumper to TP1 to override
TP20
Logic Low Primary Overcurrent Shutdown (momentary)
TP26
Logic Low CSR input
TP22
Current Demand Signal
TP25
Gate Drive Signal A
TP24
Gate Drive Signal B
LED Description
D1
Start
D2
CD Enable
D20
CSR
D36
Drag On
D39
Pilot
D45
PWM Enabled
Summary of Contents for PakMaster 50 XL Plus
Page 1: ...Manual No 0 2745 August 12 1999 Service Manual A 02464 Air Plasma Cutting Power Supply...
Page 3: ...Record Serial Numbers For Warranty Purposes...
Page 4: ......
Page 16: ...SECTION 2 INTRODUCTION 10 Manual 0 2745...
Page 34: ...SECTION 4 SERVICE TROUBLESHOOTING 28 Manual 0 2745...
Page 44: ...SECTION 5 REPLACEMENT PROCEDURES 38 Manual 0 2745...
Page 73: ...Manual 0 2745 67 APPENDIX A 02503 OK OK TO MOVE 8 11 99...
Page 74: ...APPENDIX 68 Manual 0 2745...