INSTALLATION
3-8
Manual 0-2868
Adapter
(Supplied With
Power Supply)
Pilot Lead
Torch Lead
Assembly
Negative/Plasma
Lead
Adapter Connector
Pilot Lead
Stud
Negative/Plasma
Lead Connection
A-02829
Control (PIP) Circuit
Connectors
Shield Connectors
Torch Lead Connections
6. Place the lug on the Pilot Control Wire onto the
stud and secure with the nut and washer removed
in the above Step.
7. Tighten the Strain Relief onto the Torch Leads.
8. Check the torch for proper parts assembly.
CAUTION
The torch parts must correspond with the type of
operation. Refer to the appropriate torch manual
for proper parts selection.
D. Remote Pendant Control (Optional)
In machine type operations the Power Supply has an
Adapter with a cable connector supplied at each end
of the Adapter. One end is connected at the factory
to the mating connector on the Power Supply Bulk-
head area. The other end allows connection of a Re-
mote Pendant. The remote pendant lead connector
allows connection to a remote pendant or CNC cable
while using Control (PIP) Circuit connections in the
Torch Assembly.
Connect the remote pendant control cable to the con-
nector provided on the Adapter from the Power Sup-
ply.
NOTE
Refer to Appendix 3, Torch Control Cable Wiring
Diagram For Mechanized Systems, for detailed
schematic of the Adapter.
2
3
4
12
14
13
Torch Control
Cable Connector
Remote Pendant
Cable Connector
PIP
Circuit
Control
3
4
12
14
13
A-03102
Remote Pendant Connector Diagram