CUTMASTER 40MM
Manual 0-5084
OPERATION
4-1
SECTION 4 SYSTEM:
OPERATION
4.01 Front Panel Controls / Features
See Illustration for numbering Identification
1. Output Current Control
Sets the desired output current. Output settings up
to 60 Amps may be used for drag cutting (with the
torch tip contacting the workpiece) or higher for
standoff cutting.
2. Function Control
Function Control Knob, Used to select between the
different operating modes.
SET
Used to purge the air through the unit
and torch and leads and to adjust gas pressure.
RUN
Used for general cutting operations
RAPID AUTO RESTART
Allows for faster
restarting of the Pilot Arc for uninterrupted cutting.
LATCH
Used for longer hand held cuts.
Once a cutting arc is established, the torch switch can
be released. The cutting arc will remain ON until the
torch is lifted away from the work piece, the torch
leaves the edge of the work piece the torch switch
is activated again or if one of the system interlocks
is activated.
3. ON OFF Power Switch
ON / OFF
Switch controls input power to the
power supply. Up is ON, down is OFF.
4. Air/Gas Pressure Control
The Pressure
+
Control is used in the "SET"
mode to adjust the air/gas pressure. Pull the knob
out to adjust and push in to lock.
5.
AC Indicator
Steady light indicates power supply is ready for
operation. Blinking light indicates unit is in pro-
tective interlock mode. Shut unit OFF, shut OFF or
disconnect input power, correct the fault, and restart
the unit. Refer to Section 5 for details.
A
+
PSI
BAR
MAX
MAX
MIN
MIN
!
1
2
3
4
5 6 7 8 9
Art# A-07886
MIN
MAX
10
6.
Temp Indicator
Indicator is normally OFF. Indicator is ON when
internal temperature exceeds normal limits. Let the
unit cool before continuing operation.
7.
Gas Indicator
Indicator is ON when minimum input gas pressure
for power supply operation is present. Minimum
pressure for power supply operation is not sufficient
for torch operation.
8.
DC Indicator
Indicator is ON when DC output circuit is active.
9.
!
Fault Error Indicator
Indicator is ON when Fault circuit is active. See sec-
tion 5 for explanations of fault lights.
Summary of Contents for CutMaster 40MM
Page 6: ...This Page Intentionally Blank...
Page 24: ...CUTMASTER 40MM INTRODUCTION Manual 0 5084 2T 4 This Page Intentionally Blank...
Page 28: ...CUTMASTER 40MM INSTALLATION Manual 0 5084 3 4 This Page Intentionally Blank...
Page 34: ...CUTMASTER 40MM OPERATION Manual 0 5084 4 4 This Page Intentionally Blank...
Page 43: ...CUTMASTER 40MM Manual 0 5084 OPERATION 4T 9 This Page Intentionally Blank...
Page 56: ...CUTMASTER 40MM OPERATION Manual 0 5084 4T 22 This Page Intentionally Blank...
Page 69: ...CUTMASTER 40MM Manual 0 5084 PARTS LIST 6 3 7 5 6 3 4 2 Art A 07993_AB 1 8...
Page 71: ...CUTMASTER 40MM Manual 0 5084 PARTS LIST 6 5 A 07994_AB 1 4 2 3 5 6 7 8 9 10 12 11 10 13...
Page 74: ...CUTMASTER 40MM PARTS LIST Manual 0 5084 6 8 This Page Intentionally Blank...
Page 79: ...CUTMASTER 40MM Manual 0 5084 APPENDIX A 5 This Page Intentionally Blank...
Page 83: ...This Page Intentionally Blank...