Manual 0-2888
5-1
SERVICE
SECTION 5:
SERVICE
5.01 General Maintenance
A. Each Use
Check torch consumables for wear, replace if necessary.
WARNING
Shut off power before inspecting or removing torch parts.
NOTE
When operating the torch in a normal condition, a
small amount of gas vents through the gap between the
shield cup and torch handle. Do not attempt to over
tighten the shield cup as irreparable damage to internal
components may result.
Art # A-03409
Large O-Ring,
Cat. No. 8-3487
Small O-Ring,
Cat. No. 8-3486
Electrode, Cat. No. 9-8215
Start Cartridge,
Cat. No. 9-8213
30Amp Cutting Tip, Cat. No. 9-8206
Shield Cup, Cat. No. 9-8218
Worn Electrode
Worn Tip