background image

TITAN 1280 USER MANUAL

16

NO.

Name

Type

Description

76

EXT_SYNC

Input

Input (3.3V)

Reserved (off by default)

57

LVDS_D4P

Output LVDS (2.5V)

Data signal

59

LVDS_D4N

Data signal

61

LVDS_D3N

Data signal

63

LVDS_D3P

Data signal

65

LVDS_D2P

Data signal

67

LVDS_D2N

Data signal

69

LVDS_D1N

Data signal

71

LVDS_D1P

Data signal

75

LVDS_CLKP

Clock signal

77

LVDS_CLKN

Clock signal

5, 6, 7, 

8, 19, 

20, 40, 

41, 55, 

58, 68, 

70, 73, 

79, 80

GND

Power

Ground of power

 3

Note:

1. 

Typical value of power supply is 4 V DC; here refers to the voltage value of the thermal camera 

connector, power setup time (10% ~ 90%) < 4 mS, peak current > 1.0 A, ripple and noise < 40 

mVp-p. All these requirements shall be met when the power supply reaches to the connector 

on the core.

2. 

All the TX and RX of serial communication interfaces refer to the thermal camera’s sending 

and receiving.

3. 

GND and VGND are shorted internally.

Summary of Contents for TITAN 1280

Page 1: ...SWITCHING THE UNIT ON IMPORTANT SAFETY INFORMATION INSIDE Shown with a 25 mm lens Thermal Camera cores fall under US Federal Law and Export Control Specifications subject to change without notice 855 W Cardinal Dr Suite A Beaumont TX 77705 Phone 409 861 0788 Toll Free 866 861 0788 ...

Page 2: ...TITAN 1280 USER MANUAL 2 Revision History 04 2022 001 Document created ...

Page 3: ...ations 11 Lens Options and Model Numbers 13 5 1 Titan 1280 13 Structure 14 6 1 Pin Layout 14 6 2 Pin Connector Interface Description 14 Digital Video 19 7 1 Digital Video 19 7 1 1 LVCMOS 14 bit or 10 bit 19 7 1 2 LVDS_H 20 7 1 3 BT 1120 21 7 1 4 BT 656 21 7 1 5 CDS_2 21 7 1 5 1 External Sync 22 7 1 5 2 Internal Sync 22 7 2 Data Processing 23 Temperature Measurement Functions 24 8 1 Measurement Too...

Page 4: ...TITAN 1280 USER MANUAL 4 10 4 Storage 27 About Thermal Camera 28 11 ...

Page 5: ...written permission of Thermal Camera The documentation must not in whole or part be copied photocopied reproduced translated or transmitted to any electronic medium or machine readable form without prior consent in writing from Thermal Camera Names and marks appearing on the products herein are either registered trademarks or trademarks of Thermal Camera and or its subsidiaries All other trademark...

Page 6: ...heeled bin symbol indicates that waste electrical and electronic equipment should not be discarded together with unseparated household waste but must be collected separately All local authorities have established collection schemes under which residents can dispose of equipment at a recycling center or other collection points or WEEE will be collected directly from households More detailed informa...

Page 7: ...d features multiple image output interfaces The Titan 1280 offers comprehensive analysis functions and can serve a wide range of temperature measurement applications Environment of use industrial and petrochemical buildings electrical plants security rooms science labs environmental conservatories among others You agree that this product is for civilian use only and shall not use applications that...

Page 8: ...TITAN 1280 USER MANUAL 8 2 9 Training To read about infrared training visit https infraredtraininginstitute com ...

Page 9: ...ly the device may be damaged Do not put holes in the device with objects Damage to the device may occur Do not hit the device with a hammer or apply strong impacts or electric shocks to it Damage to the device may occur Do not put the device in or near a fire stove or other high temperature locations Damage or ignition of the device may occur Do not put the device in direct sunlight or other high ...

Page 10: ...nough for the condensation to evaporate Keep device out of reach of children This product is a precise electronic device that must be handled with care during use storage and transportation to prevent dangerous actions such as the device being hit by external force or falling from heights Transport During transportation and storage the original packaging box must be used Storage If you do not use ...

Page 11: ...tion Over voltage Under voltage Reverse Connection Startup Time 15s Weight without lens 150 g 5 29 oz 3 g 0 11 oz Zoom 1 0X 4 0X continuous zoom Interface RS 232 UART 3 3 V Extension Board Cameralink LVDS USB3 0 Video Digital 14 bit or 16 bit LVCMOS LVDS 4 Video Mirror Horizontal Vertical Diagonal 6 Image Polarity White hot or black hot Image Processing Digital filter Imaging denoising Detail enha...

Page 12: ...g voltage is 4V DC Expansion components support 5V 24V DC 3 This function is only available in analog video and digital BT 656 4 10 bit or 14 bit LVCMOS digital video is only available in Hirose 80 Pin Interface 5 The data format of analog video is PAL D 6 These functions are supported in analog video BT 1120 BT 656 and LVDS DRC_Color ...

Page 13: ... 5 1 Titan 1280 Titan 1280 Lens Options Model No Focal Length F Focus Type FOV HxV IFOV ICITitan1280P X 44 19 mm 1 0 Athermal 44 x35 8 0 630 mrad ICITitan1280P X 50 17 mm 1 0 Athermal 50 x40 0 710 mrad ICITitan1280P X 32 25 mm 1 0 Athermal 32 x27 0 500 mrad ICITitan1280P X 16 50 mm 1 0 Athermal 16 x13 5 0 250 mrad ICITitan1280P X 05 150 mm 1 0 Athermal 5 x3 7 0 070 mrad X calibration type Industri...

Page 14: ...on between the thermal camera and user expansion boards Among the digital video interfaces BT 656 and BT 1120 reuse interfaces of 10 bit or 14 it LVCMOS digital video LVDS digital video has independent interfaces 6 Structure 6 2 Pin Connector Interface Description CONTINUES PLEASE READ AND UNDERSTAND THE TABLES BEFORE SWITCHING THE UNIT ON NO Name Type Description 1 2 3 4 Power Supply Power Power ...

Page 15: ...DV14 Data 37 Line_Valid Digital video Line valid signal Line valid signal 38 Frame_Valid Frame valid signal Frame valid signal 39 Clock Clock signal Clock signal 42 MOTOR_FP Input Motor interface 3 3V Reserved 44 MOTOR_FN Reserved 46 MOTOR_ZP Reserved 48 MOTOR_ZN Reserved 50 MOTOR_SDA Reserved 52 MOTOR_SCL Reserved 43 GPIO2 Input Output Input Output 3 3V Reserved 45 GPIO3 Reserved 47 GPIO4 Reserve...

Page 16: ...ock signal 77 LVDS_CLKN Clock signal 5 6 7 8 19 20 40 41 55 58 68 70 73 79 80 GND Power Ground of power 3 Note 1 Typical value of power supply is 4 V DC here refers to the voltage value of the thermal camera connector power setup time 10 90 4 mS peak current 1 0 A ripple and noise 40 mVp p All these requirements shall be met when the power supply reaches to the connector on the core 2 All the TX a...

Page 17: ...rmats which are 14 bits and 10 bits When original data RAW or temperature data TMP is selected the data has 14 bits which are DV 13 0 among them DV0 is LSB and DV13 is MSB When data after image processing DRC is selected the data has 10 bits which are DV 9 0 among them DV0 is LSB DV9 is MSB LVCMOS digital video can be enabled or disabled through control command Original data RAW temperature data T...

Page 18: ...cessing DRC DRC_Gray DRC_Color can be selected When the original data RAW and temperature data TMP are selected function of polarity selection digital zoom digital detail enhancement digital filter and imaging denoising and temperature display are not supportable When data after image processing DRC is selected function of digital zoom and temperature display are not supportable LVDS_H Clock Frequ...

Page 19: ...s The first part is image data in YUV422 format the higher 8 bits data defines luminance the lower 8 bits data defines chrominance supporting color palette mapping the followed part is temperature data only 14 bits are valid bits write 0 to the highest 2 bits There are two kinds of sync for CDS_2 external sync and internal sync The data is synchronized by Vsync signals and Hsync signals for extern...

Page 20: ...data includes 640x2 1280 clocks N 640 each frame includes 512 lines M 512 The data is synchronized by Vsync signals and Hsync signals for external sync The data is synchronized by adding sync codes for internal sync One Frame Data Format of CD_2 Video Invalid line reference number EAV 0xB6B6 Blanking 0x1080 Invalid line reference number SAV 0xABAB Invalid data 0x1080 Valid line reference number EA...

Page 21: ...TITAN 1280 USER MANUAL 21 CDS_2 video includes internal sync and external sync see the following image for the sequence format of CDS_2 video with one line valid data 7 2 Data Processing ...

Page 22: ... In the full frame and area temperature measurement modes the maximum temperature minimum temperature center temperature and average temperature can be displayed Analysis can be enabled or disabled The area size and position can be adjusted through PC software Up to 12 areas or lines are supported in the area temperature measurement mode Users can also configure temperature correction data through...

Page 23: ...n 7 1 1 LVCMOS and Section 7 1 2 LVDS_H for the data format The temperature is in Kelvin format There are two different kinds of data calculation format for which the user can consult the detailed usage or switch method The two different data calculation formats are as follows Format 1 Value T x10 Format 2 Value T x10 7000 0 Value 7300 T x15 3300 7301 Value 16383 ...

Page 24: ...on Power supply 5 V 24 V DC typical voltage 12 V DC USB Type C Cameralink USB Type C Cameralink connector Coming Soon Power supply 5 V 24 V DC typical voltage 12 V DC USB Type C USB Type C Coming Soon Power supply 5 V 24 V DC typical voltage 12 V DC LVDS H RS232 Samtec TFM 115 02 L D WT Coming Soon Power supply 5 V 24 V DC typical voltage 12 V DC Cameralink RS232 RS422 Samtec TFM 115 02 L DH 9 Use...

Page 25: ...place the cloth and repeat operation 10 2 Disinfecting the Camera Surface Do not use corrosive cleaning solutions on the optical glass components Do not get the electronics wet It is recommended to disinfect the camera surface regularly with a non corrosive sanitizing product Follow the directions provided by the manufacturer of the cleaning solution Adhere to the sanitation protocols and cleaning...

Page 26: ...tists inspectors and operators in space power companies medical pulp and paper food industry research and development and various process industries Thank you for your dedicated and continued support Thermal Camera 855 W Cardinal Dr Suite A Beaumont TX 77705 Phone 409 861 0788 Toll Free 866 861 0788 International 409 861 0788 Customer Support support thermalcamera com Website www thermalcamera com...

Reviews: