![Thermal Arc ARCMASTER 200 TS Service Manual Download Page 26](http://html1.mh-extra.com/html/thermal-arc/arcmaster-200-ts/arcmaster-200-ts_service-manual_1103173026.webp)
200TS
4
OPERATOR CONTROL
4 – 2
3.
Positive Terminal:
Welding current flows from the Power Source
via heavy duty Dinse type terminal (25 mm)
It is essential, however, that the male plug
is inserted and turned securely to achieve a
sound electrical connection.
4.
Negative Terminal:
Welding current flows from the Power Source
via heavy duty Dinse type terminal (25 mm)
It is essential, however, that the male plug
is inserted and turned securely to achieve a
sound electrical connection.
CAUTION
Loose welding terminal connections can cause
overheating and result in the male plug being fused
in the bayonet terminal.
5.
Torch/Gas Terminal:
Torch/Gas Terminal is an all-in-one design of
the Gas Outlet and the Negative Terminal. Gas
Outlet is a BSP-3/8 inch female gas fitting.
6.
ON/OFF Switch:
This switch connects the Primary supply volt-
age to the inverter when in the ON position.
This enables the Power Supply.
WARNING
When the welder is connected to the Primary sup-
ply voltage, the internal electrical components
may
be at 240V potential with respect to earth.
7.
Input Cable:
The input cable connects the Primary supply
voltage to the equipment.
8.
Gas Inlet:
The Gas Inlet is BSP-3/8 inch female gas fit-
ting.
2
Weld Process selection for
200TS
Table 4-2: Weld Process selection verses Weld Mode for
200TS
Weld Mode
Weld Process
Selection
STICK MIG
LIFT
TIG
Description
Yes Yes Yes
2T operation in
TIG Modes using
remote devices to
control contactor &
current
No
Yes Yes
4T operation in
TIG Modes with
crater fill using a
remote contactor
device to control
sequence.
No
Yes Yes
4T operation in
TIG Modes with
repeat operation
and crater fill using
a remote contactor
device.
No
Yes No
2T operation spot
welding in HF TIG
using a remote
contactor device.
No
Yes Yes
Pulse operation in
TIG Modes
STD
SLOPE
REPEAT
SPOT
PULSE ON/OFF
Summary of Contents for ARCMASTER 200 TS