pro-wave 300gtsw
6-32
June 21, 2012
6.29 PCA Output Diodes (D2-D5) Test Procedure
!
WARNING
Disconnect primary power at the source before performing this procedure.
Refer to figure 6-29 below.
The output section contains four diodes, D2 through D5. Check each diode between its POSITIVE (A) and NEGATIVE
(K) TERMINALS. Refer to figure 6-29. Note that these measurements can be accomplished without removing the main
transformers. (The transformers were removed in figure 6-29 to aid in identifying the diodes.)
To check for shorted diodes without dismantling the power supply, take a voltmeter set on the diode scale from the
GRAY wire and the BROWN on the FCH to the NEGATIVE weld terminal. A good reading will be .2V.
D3
D5 D5-K
D5-A/D3-A
D4
D2-A/D4-K
D2-K
D4-A
D3-K
D2
Art # A-06130
Figure 6-29: Power control assembly - output diodes (D2-D5) (Main transformers removed for clarity)
Summary of Contents for 300GTSW Pro-Wave
Page 26: ...pro wave 300gtsw 2 8 June 21 2012 This page left blank intentially ...
Page 32: ...pro wave 300gtsw 4 4 June 21 2012 This page left blank intentially ...
Page 38: ...pro wave 300gtsw 5 6 June 21 2012 This page left blank intentially ...
Page 67: ...pro wave 300gtsw June 21 2012 6 29 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 100: ...pro wave 300gtsw 7 8 June 21 2012 6 16 17 Art A 06151 Figure 7 3 Rear Panel ...
Page 105: ...pro wave 300gtsw June 21 2012 7 13 77 26 36 1 36 Art A 06159 Figure 7 11 Output diode bus bar ...
Page 106: ...pro wave 300gtsw 7 14 June 21 2012 76 Art A 06160 Figure 7 12 Main Transformer ...
Page 110: ...pro wave 300gtsw 7 18 June 21 2012 This page left blank intentially ...
Page 121: ...pro wave 300gtsw June 21 2012 A 11 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 129: ...This page left blank intentially ...