Thermal Arc 175 SE ARC MASTER Operating Manual Download Page 9

March 20, 2007                                                                             1-3                                                                              Manual 0-5054 

 SAFETY INSTRUCTIONS 

ARC MASTER 175 SE

10.  Remove stick electrode from holder or cut off welding wire 

at contact tip when not in use.

   WARNING

FLYING  SPARKS  AND  HOT  METAL  can  cause 

injury.

Chipping and grinding cause flying metal. As welds 

cool, they can throw off slag. 

1.  Wear approved face shield or safety goggles. Side shields 

recommended.

2.  Wear proper body protection to protect skin.

   WARNING

CYLINDERS can explode if damaged.

Shielding  gas  cylinders  contain  gas  under  high 

pressure.  If  damaged,  a  cylinder  can  explode. 

Since gas cylinders are normally part of the welding 

process, be sure to treat them carefully.

1.  Protect  compressed  gas  cylinders  from  excessive  heat, 

mechanical shocks, and arcs.

2.  Install and secure cylinders in an upright position by chaining 

them to a stationary support or equipment cylinder rack to 

prevent falling or tipping.

3.  Keep  cylinders  away  from  any  welding  or  other  electrical 

circuits.

4.  Never allow a welding electrode to touch any cylinder.

5.  Use only correct shielding gas cylinders, regulators, hoses, 

and fittings designed for the specific application; maintain 

them and associated parts in good condition.

6.  Turn  face  away  from  valve  outlet  when  opening  cylinder 

valve.

7.  Keep protective cap in place over valve except when cylinder 

is in use or connected for use.

8.  Read and follow instructions on compressed gas cylinders, 

associated  equipment,  and  CGA  publication  P-1  listed  in 

Safety Standards.

!

  WARNING

Engines can be dangerous.

    WARNING

ENGINE EXHAUST GASES can kill.

Engines produce harmful exhaust gases.

1.  Use equipment outside in open, well-ventilated areas.

2.  If used in a closed area, vent engine exhaust outside and away 

from any building air intakes.

  WARNING

ENGINE FUEL can cause fire or explosion.

Engine fuel is highly flammable.

1.  Stop engine before checking or adding fuel.

2.  Do not add fuel while smoking or if unit is near any sparks 

or open flames.

3.  Allow engine to cool before fuelling. If possible, check and 

add fuel to cold engine before beginning job.

4.  Do not overfill tank — allow room for fuel to expand.

5.  Do not spill fuel. If fuel is spilled, clean up before starting 

engine.

  WARNING

MOVING PARTS can cause injury.

Moving parts, such as fans, rotors, and belts can cut fingers and 

hands and catch loose clothing.

1.  Keep all doors, panels, covers, and guards closed and 

securely in place.

2.  Stop engine before installing or connecting unit.

3.  Have only qualified people remove guards or covers for 

maintenance and troubleshooting as necessary.

4.  To  prevent  accidental  starting  during  servicing, 

disconnect negative (-) battery cable from battery.

5.  Keep hands, hair, loose clothing, and tools away from 

moving parts.

6.  Reinstall  panels  or  guards  and  close  doors  when 

servicing is finished and before starting engine.

  WARNING

SPARKS can cause BATTERY GASES TO EXPLODE; 

BATTERY ACID can burn eyes and skin.

Batteries contain acid and generate explosive gases.

1.  Always wear a face shield when working on a battery.

2.  Stop  engine  before  disconnecting  or  connecting  battery 

cables.

3.  Do  not  allow  tools  to  cause  sparks  when  working  on  a 

battery.

4.  Do  not  use  welder  to  charge  batteries  or  jump  start 

vehicles.

5.  Observe correct polarity (+ and –) on batteries.

Summary of Contents for 175 SE ARC MASTER

Page 1: ...50 60 Hz A 08598 ARC MASTER Inverter Arc Welder 175 SE Operating Manual Revision No AE Issue Date February 24 2009 Manual No 0 5054 Operating Features...

Page 2: ...Precautions They will help you to avoid potential hazards that may exist when working with this product YOU ARE IN GOOD COMPANY The Brand of Choice for Contractors and Fabricators Worldwide ThermalAr...

Page 3: ...hermalarc com Copyright 2008 by Thermadyne Industries Inc All rights reserved Reproduction of this work in whole or in part without written permission of the publisher is prohibited The publisher does...

Page 4: ...Electrical Input Connections 3 1 3 04 Electromagnetic Compatibility 3 3 3 05 Setup for Welding 3 4 3 06 Manual Arc STICK Setup 3 5 3 07 Lift TIG GTAW Setup 3 6 SECTION 4 OPERATION 4 1 4 01 Front Pane...

Page 5: ...01 Routine Maintenance and Inspection 5 1 5 02 STICK Welding Problems 5 2 5 03 TIG Welding Problems 5 3 5 04 Power Source Problems 5 4 5 05 Key Spare Parts 5 4 LIMITED WARRANTY WARRANTY SCHEDULE 2 GLO...

Page 6: ......

Page 7: ...Wear a safety harness to prevent falling if working above floor level 15 Keep all panels and covers securely in place WARNING ARC RAYS can burn eyes and skin NOISE can damage hearing Arc rays from th...

Page 8: ...material 3 Remove all flammables within 35 10 7m of the welding arc If this is not possible tightly cover them with approved covers 4 Be alert that welding sparks and hot materials from welding can ea...

Page 9: ...GINE EXHAUST GASES can kill Engines produce harmful exhaust gases 1 Use equipment outside in open well ventilated areas 2 If used in a closed area vent engine exhaust outside and away from any buildin...

Page 10: ...lowing procedures 1 Keep cables close together by twisting or taping them 2 Arrange cables to one side and away from the operator 3 Do not coil or drape cable around the body 4 Keep welding power sour...

Page 11: ...Welding GMAW Increase Decrease Circuit Breaker AC Auxiliary Power Remote Duty Cycle Percentage Amperage Voltage Hertz cycles sec Frequency Negative Positive Direct Current DC Protective Earth Ground L...

Page 12: ...it t les pi ces endommag es 13 Dans des espaces confin s ou mouill s n utilisez pas de source de courant alternatif moins qu il soit muni d un r ducteur de tension Utilisez plut t une source de couran...

Page 13: ...s l ments peuvent d gager des fum es toxiques au moment du soudage AVERTISSEMENT LE SOUDAGE PEUT CAUSER UN INCENDIE OU UNE EXPLOSION L arc produit des tincellies et des projections Les particules vola...

Page 14: ...cher de tomber ou d tre renver s es 3 Eloignez les bouteilles de tout circuit lectrique ou de tout soudage 4 Emp chez tout contact entre une bouteille et une lectrode de soudage 5 N utilisez que des...

Page 15: ...idi 2 Mettez des gants et posez un torchon sur le bouchon pour l ter 3 Laissez la pression s chapper avant d ter compl tement le bouchon PLOMB AVERTISSEMENT Ce produit contient des produits chimiques...

Page 16: ...Augmentez Diminuer Disjoncteur Source AC Auxiliaire Distant Facteur de Marche Pourcentage Intensit de Courant Tension Hertz cycles sec Fr quence N gatif Positif Courant Continue DC Terre de Protectio...

Page 17: ...equirements Among them are CENELEC EN50199 EMC Product Standard for Arc Welding Equipment ISO IEC 60974 1 BS 638 PT10 EN 60 974 1 EN50192 EN50078 applicable to welding equipment and associated accesso...

Page 18: ...Manual 0 5054 1 12 March 20 2008 ARC MASTER 175 SE SAFETY INSTRUCTIONS...

Page 19: ...h complete information concern ing damage claims or shipping errors to the location in your area listed in the inside back cover of this manual Include all equipment identification numbers as describe...

Page 20: ...x D 230mm Power Source Part Number Welding Output Welding output 40 C 10 min quoted figures refer to SMAW output Dimensions and Weight Dimension power source DxWxH Mains Power Classification Motor st...

Page 21: ...n areas not exposed to direct sunlight or rain Place at a distance of 12 300mm or more from walls or similar that could restrict natural air flow for cooling WARNING Thermal Arc advises that this equi...

Page 22: ...0 National Electrical Code Input Power Each unit incorporates an INRUSH circuit When the MAIN CIRCUIT SWITCH is turned on the inrush circuit provides pre charging for the input capacitors A relay in t...

Page 23: ...erence occurs it may be necessary to take additional precautions such as filtering of the mains supply Consideration should be given to shielding the supply cable of permanently installed welding equi...

Page 24: ...uide only Current delivered to the arc is dependent on the welding arc voltage and as weld ing arc voltage varies between different classes of electrodes welding current at any one setting would vary...

Page 25: ...d Current control to the desired welding current 6 Switch the ON OFF Switch located on the rear panel to the ON position This will immediately energize the power supply up to the output terminals and...

Page 26: ...l to the desired welding current 6 Switch the ON OFF Switch to the ON position 7 Commence welding If necessary readjust the Weld Current control to obtain the welding condition re quired 8 After compl...

Page 27: ...before resuming welding A Process Selection Switch Switches between Lift TIG and Manual Arc STICK Weld ing modes B Power On Indicator The Power ON Indicator illuminates when the ON OFF switch is in t...

Page 28: ...zone in the weld area and if suitable precautions are not taken the occurrence in this zone of under bead cracks Hardened zone and under bead cracks in the weld area may be reduced by using the correc...

Page 29: ...ation Features Colour Code Thoriated 2 DC welding of mild steel stainless steel and copper Excellent arc starting long life high current carrying capacity Red Ceriated 2 AC DC welding of mild steel st...

Page 30: ...ing in flat horizontal vertical and overhead positions Numerous applications call for welds to be made in positions intermediate between these Some of the common types of welds are shown in Figures 4...

Page 31: ...simplest way to commence is to run beads on a piece of scrap plate Use mild steel plate about 1 4 6 0mm thick and a 1 8 3 2mm electrode Clean any paint loose scale or grease off the plate and set it f...

Page 32: ...mes almost automatic You will find that A very long arc produces a crackling or spluttering noise and the weld metal comes across in large irregular blobs The weld bead is flattened and spatter increa...

Page 33: ...hese are welds of approximately triangular cross section made by depositing metal in the corner of two faces meeting at right angles Refer to Figure 4 5 A piece of angle iron is a suitable specimen wi...

Page 34: ...tip of the electrode just keeps ahead of the slag The electrode should point upwards at an angle of about 45 3 Overhead Welds Apart from the rather awkward position necessary overhead welding is not...

Page 35: ...mensions In a welded joint the metal becomes attached to the side of the joint and cannot contract freely Therefore cooling causes the weld metal to flow plastically that is the weld itself has to str...

Page 36: ...pleted the sections b and c will contract at a similar rate thus reducing distortion Art A 07707 Figure 4 22 Principle of presetting Art A 07708 B Preheat Preheat Dotted lines show effect if no prehea...

Page 37: ...essary with solvents that are recommended for cleaning electrical apparatus CAUTION Do not blow air into the power supply during cleaning Blowing air into the unit can cause metal particles to interfe...

Page 38: ...rode angle incorrect rate of travel too high A Small electrodes used on heavy cold plate B Welding current is too low C Wrong electrode angle D Travel speed of electrode is too high E Scale or dirt on...

Page 39: ...ode by grinding contaminates off B Check gas lines for cuts and loose fitting or change gas cylinder 8 Poor weld finish Inadequate shielding gas Increase gas flow or check gas line for problems 9 Arc...

Page 40: ...use Remedy 1 The welding arc cannot be established A The Primary supply voltage has not been switched ON B The Welding Power Source switch is switched OFF C Loose connections internally A Switch ON th...

Page 41: ......

Page 42: ...written consent obtained from Thermadyne service department UK Equipment that has been used beyond the speci cations established in the operating manual Installation not in accordance with the install...

Page 43: ...g District Shanghai PR 200052 Telephone 86 21 69171135 Fax 86 21 69171139 Thermadyne Asia Sdn Bhd Lot 151 Jalan Industri 3 5A Rawang Integrated Industrial Park Jln Batu Arang 48000 Rawang Selangor Dar...

Page 44: ...World Headquarters Thermadyne Holdings Corporation Suite 300 16052 Swingley Ridge Road St Louis MO 63017 Telephone 636 728 3000 Fax 603 728 3010 Email sales thermalarc com www thermalarc com...

Reviews: