6
0.1
Instructions General
A pressure reducing valve must be fitted to the cold water inlet if the incoming water pressure exceeds
300 KPA (3.0 Bar).
The primary operating pressure initial charge is 120 KPA (1.2 bar) this will increase to around 200 KPA
(2.0Bar) when the system has reached maximum temperature and will depend on system volume.
The primary expansion is internal and is formed when the vessel is initially filled. It has a volume of 18.5L
for the 210, 23L for the 250 and 28L for the 330 model.
The secondary expansion vessel pre-charge pressure is between 200-350 KPA (2-3.5 bar) and has a
volume of 0.5 litres.
The primary pressure relief valve is set to 300 KPA (3.0 Bar).
Thermaflow Model Number
TH6-210U M3
Primary storage capacity
200 Litres
Weight when Empty
70KG
Weight when Full
278KG
WARNING: BEFORE OBTAINING ACCESS TO TERMINALS, ALL SUPPLY CIRCUITS MUST
BE DISCONNECTED.
The
TH6
has
2
heating elements fitted. Size 16” in length and are manufactured from Inc-alloy
EN60335.2.73.
The rated power input of the
TH6
appliance is ~230- 240V, 50Hz, 5400-6000w
The elements fitted to the Thermaflow should
NOT
be replaced with elements which are not
approved for the Thermaflow boiler
.