THERMAFLOW LTD | THERMAFLOW® ELECTRIC COMBINATION BOILER |
Tel: 0870 850 5207
2.6.2f SOLID FUEL KIT WIRING CIRCUIT
22
2
C
T17
Switched Live to A2 on
solid fuel relay fitted to
Thermaflow boiler
SL from T1 on 0-90°C
Control Thermostat
fitted on boiler
Pump fitted at
Solid Fuel Boiler
Wiring diagram and additional equipment required
when linking a solid fuel appliance to the
Thermaflow boiler
0-50°C Control
Thermostat fitted to
flow pipe at solid fuel
or wood burning
appliance
1
T2
Pump at Solid Fuel Boiler
0-50°C ControlThermostat fitted to flow
pipe at solid fuel or wood burning
appliance
T17 on Thermaflow boiler terminal
Common 0-50°C ControlThermostat
fitted to flow pipe at solid fuel or wood
burning appliance
T11 on solid fuel relay fitted to Thermaflow
boiler
Junction Box
E
N
Neutral & Earth
connections not shown
for clarity
All Connections are
~240 VAC
T18